Knauf 'I' Stud Lining (fire resistance system): ISL-I-92-090-6-2x15-FP-50

Verified by manufacturer 13 hours ago

With deflection head arrangement

Knauf UK Variant:
Product certifications:
  • EPD

    EPD

    Certificate type

  • EPD

    EPD

    Certificate type

  • EPD

    EPD

    Certificate type

  • EPD

    EPD

    Certificate type

  • BS EN 13501-2:2023

    Certificate type

  • Fire resistance to BS EN 1364-1

    Certificate type

Knauf Independent ‘I’ Stud (fire resistance performance systems) is a fully independent wall lining system that can be used in all building types to upgrade the acoustic, fire and thermal performance.

Jump to:
BOS
0800 521 050 Website

Application

Fully independent wall lining system that can be used in all building types to upgrade the acoustic, fire and thermal performance of an existing masonry wall and to deal with any irregularities.

Description

Knauf Independent ‘I’ Stud (fire resistance performance systems) is a fully independent wall lining system that can be used in all building types to upgrade the acoustic, fire and thermal performance of an existing masonry wall and to deal with any irregularities.

Due do the system using an Knauf ‘I’ Stud, there is no requirement for the lining system to be fixed back into the structure behind.

Testing Methodology: BS EN 1363-1 AND BS 476-20

Knauf interior drywall partition systems* that achieve a fire resistance performance are tested in accordance with BS EN 1363-1 and BS EN 1364-1. These are the up to date and most rigorous test methodology standards to follow.

Determining the maximum height of a drywall partition as per the BS EN 1363-1 fire test methodology, is typically restricted by the 3 metre height of the test furnace.

To understand the true maximum height of the system whilst under fire test conditions (‘Fire State Height’), there are three options. Increases can be determined by utilising greater test furnace heights, via Extended Field of Application (as outlined in BS EN 15254-3 - it is important to note this standard applies to single metal frame symmetrical systems only), or via BS EN 1364-1.

The BS 476-20 standard is also restricted by the 3 metre height of the test furnace. However, under this BS standard, increasing the maximum heights of a system can be based on the ‘Cold State Height’. The cold state height is calculated using structural engineering methods to L/240 @ 200Pascals. (L = Height of wall). Regulatory Requirements

Specific to Approved Document B (England) there is a requirement to use European classifications and fire resistance test methodologies in accordance with BS EN 1363-1 and BS EN 1364-1, which means that the fire state height must be considered. However, Approved Document B (England) currently allows the usage of the BS 476 series, though it should be noted that, following consultation, the full BS 476 series will be removed in 2029. For other nationals, please consult relevant approved documents, technical guidance, and handbooks.

Knauf Approach & Recommendations:

Knauf advise and promote that EN compliance should be followed. That is to say Knauf advise utilising an BS EN 1364-1 fire resistance test and extend the maximum height of a drywall partition system via either BS EN 15254-3, BS EN 1364-1 or via a fire resistance test within a test rig greater than 3m in height.

Projects that wish to use the BS 476 series must gain agreement between the Client, Accountable Persons, Duty Holders, and Local Building Control that the cold state height is an acceptable methodology. For further information on Knauf system types that are applicable to support projects focusing on BS compliance, refer to Knauf Systems Performance Tables (BS compliance).

General information

Material

Gypsum

Metal

Stone wool

Shape

Rectangle

Other

Square

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_10_30_35 Gypsum board partition systemsPrimary

CAWS

K10/30 Metal stud

K10/125 Metal stud partition system

Product range

Wall Liners / Knauf I Stud Lining

Specification data - Gypsum board partition systems

System performance

Sound insulation, Rw (minimum) to BS EN ISO 10140-2 or BS EN ISO 140-3

N/A.

Sound insulation, Rw + Ctr (minimum) to BS EN ISO 10140-2 or BS EN ISO 140-3

N/A.

Fire resistance to BS EN 1364-1

EI 60.

Manufacturer guidance

Tested in accordance with BS EN 1364-1.

Duty rating to BS 5234-2

Severe duty (SD).

Manufacturer guidance

In accordance with BS 5234-2, clause 1.6.2 & 1.6.3 of Annex B & C.

Maximum height - cold state

5000 mm.

Thickness

124 mm.

Manufacturer guidance

Excluding finishes.

Classification data

Framing

Knauf 92 'I' (0.90) at 600 mm centres to suit maximum height.
Head channel: Knauf 94 Deep Flange 'U' Channel (0.70) (70 mm deep flange).
Floor channel: Knauf 94 Deep Flange 'U' Channel (0.70) (70 mm deep flange).

Insulation

50 mm Knauf Insulation Rocksilk® RS60.

Linings

2 x 15 mm Knauf Fire Panel to room side .

Fasteners

Inner layer: 25 mm Knauf Drywall screws – Jackpoint self drilling.
Outer layer: 42 mm Knauf Drywall screws – Jackpoint self drilling.

Joint treatment

Horizontal joint: Knauf Flat Fixing Plate (to be applied behind outer layer plasterboard).

Finish

System must be taped and jointed using Knauf Joint Filler (Premium) or Knauf Joint Cement Premium and Knauf Joint Tape (Paper). Or alternative Knauf jointing compounds manufactured to EN 13963.
Knauf Wallboard Primer applied once taping and jointing completed.
Prior to where paint decoration is required. For preparation for decoration of where gypsum plaster skim is required, the outer layer of plasterboard joints is required to be taped and filled, using Knauf Joint Filler (Premium) and Knauf Joint Tape (Paper) meeting quality level 1 in accordance with Eurogypsum - Drywall Jointing & Finishing - Surface quality level classification.
For application where gypsum skim finish is required, the Knauf system is to be taped and filled using Knauf jointing compounds.

Execution

Consult manufacturer's literature at
https://www.knauf.co.uk/our-services/resources

Deflection head

For deflection head allowance of up to -25 mm or ±12.5 mm: use 2 x 19 mm Knauf Coreboard fillets, Knauf Insulation Rocksilk® RS60 retained by Knauf Angle Sections 25 x 50 mm.

Manufacturer guidance

The fire resistance performance of the system is based on tested solutions using deflection head construction.

System code

EN-ISL-I-92-090-6-2x15-FP-50.

Guidance for specification option:

The maximum height stated (see Partition height) is the lower value between the cold state height, calculated structurally to limiting deflection of L/240 @ 200 Pa and the fire state height, as outlined in accordance with BS EN 1364-1.

BS-ISL-I-92-090-6-2x15-FP-50.

Guidance for specification option:

The maximum height stated (see Partition height) is the lower value between the cold state height, calculated structurally to limiting deflection of L/240 @ 200 Pa and the fire state height, as outlined in accordance with BS EN 1364-1.

Partition height

-

Manufacturer guidance

Insert requirements, maximum 5000 mm.

See System code for further details.

Sustainability data

Country of material origin

Spain

Manufacturer guidance

Applies to our natural gypsum only which is the main component of plasterboard. Other components are from other countries. Please contact Knauf for more details.

Country of product manufacture

United Kingdom

Manufacturer guidance

UK applies to the majority of manufacture but a small percentage of finished items may be imported. Please contact Knauf for more details.

Material

Gypsum
Metal
Stone wool

Recyclability

Individual product EPDs for plasterboard and metal components available at: https://www.knauf.co.uk/our-services/resources/environmental-product-declarations-1

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

12.64 %

Manufacturer guidance

(2024 average by mass for all UK produced plasterboards, recycled gypsum & paper)

Product certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC
-

1

Revit
-

1

Product certifications

EPD

EPD

Knauf Coreboard EPD

EPD

EPD

Knauf Fire Panel EPD

EPD

EPD

Knauf Internal Metal Partition Components EPD

EPD

EPD

Knauf Insulation Rocksilk RS60 EPD

BS EN 13501-2:2023

BS EN 13501-2:2023

Fire Classification Report - ISL-I-92-090-070-6-2x15-FP-50 - FCR

Fire resistance to BS EN 1364-1

Fire resistance to BS EN 1364-1

Fire Test Report - ISL-I-92-090-070-6-2x15-FP-50 - FTR

Literature

Knauf Fire Panel Data Sheet

Knauf Fire Panel Data Sheet

Knauf Core Board Data Sheet

Knauf Core Board Data Sheet

Knauf DF U Channel Data Sheet

Knauf DF U Channel Data Sheet

Knauf Rocksilk Building Slab Data Sheet

Knauf Rocksilk Building Slab Data Sheet

Knauf Angle Section Data Sheet

Knauf Angle Section Data Sheet

Knauf Intumescent and Acoustic Mastic Data Sheet

Knauf Intumescent and Acoustic Mastic Data Sheet

Knauf U Channel Data Sheet

Knauf U Channel Data Sheet

Knauf Jackpoint Screws Data Sheet

Knauf Jackpoint Screws Data Sheet

Knauf I Stud Data Sheet

Knauf I Stud Data Sheet

Knauf Flat Fixing Plate Data Sheet

Knauf Flat Fixing Plate Data Sheet

Knauf Wafer Head Self Tapping Screw Data Sheet

Knauf Wafer Head Self Tapping Screw Data Sheet

Knauf Fill and Finish Light Data Sheet

Knauf Fill and Finish Light Data Sheet

Knauf Paper Joint Tape Data Sheet

Knauf Paper Joint Tape Data Sheet

Knauf Systems Performance Tables (EN Compliance)

Knauf Systems Performance Tables (EN Compliance)

Knauf Systems Performance Tables (BS Compliance)

Knauf Systems Performance Tables (BS Compliance)

Knauf Fire Rated Deflection Heads Document

Knauf Fire Rated Deflection Heads Document

Knauf Standard Details - I Stud Lining Double Boarded

Knauf Standard Details - I Stud Lining Double Boarded

Knauf Standard Details - (≥ 5m) I Stud Lining Double Boarded

Knauf Standard Details - (≥ 5m) I Stud Lining Double Boarded

The 100% Knauf System Performance Warranty

The 100% Knauf System Performance Warranty

Knauf Specification Disclaimer

Knauf Specification Disclaimer

Supporting guidance on Knauf testing documentation

Supporting guidance on Knauf testing documentation

Similar products from Knauf UK

Knauf 'I' Stud Lining (fire resistance system): ISL-I-70-070-6-2x15-FP-50

Knauf 'I' Stud Lining (fire resistance system): ISL-I-70-070-6-2x15-FP-50

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-3-2x15-SSP-50

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-3-2x15-SSP-50

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-4-1-12.5-WB-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-4-1-12.5-WB-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1-12.5-MP-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1-12.5-MP-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1x12.5-WB-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1x12.5-WB-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1x15-SSP-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1x15-SSP-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-12.5-WB-25

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-12.5-WB-25

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-15-SSP-25

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-15-SSP-25

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-15-SSP-50

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-15-SSP-50

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-15-WB-25

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-15-WB-25