NBS Source
I'm a manufacturer
Compare variants

Kingframe Steel Frame System SFS

Verified by manufacturer 4 months ago

70 mm

Kingspan Insulated Panels Variant:
Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

Light gauge steel framing.

Jump to:
+44 (0)1352 716440 Website

Application

Infill systems:

Typically supported at the slab edge between hot-rolled steel or concrete primary support frame. The secondary SFS frameworks are typically assembled as kit form on site or, for more rapid installation, the SFS frameworks as part of Modern Methods of Construction (MMC) may be provided as a pre-panelised solution that is factory-assembled off-site. Such pre-assembled panels may be supplied in either small or large format depending on individual project requirements. The SFS framework allows insulation and external finishes to be installed outside the main structural frame if the correct tolerance scheme is adopted. The system is suitable for both low and high-rise construction. A deflection allowance is required at each floor level. Kingframe infill systems are BBA approved.


Oversail systems:

Fitted outside the line of the structural frame using support cleats at each floor level with connections designed to allow slab deflection. It is particularly suited to situations where cladding materials are sensitive to differing movement of the main frame. Adequate base support must be provided to accommodate vertical loading. Kingframe oversail systems are BBA approved.


Load bearing systems:

The SFS studs are designed to provide primary support for vertical (axial) compressive loads from the roof and floors of the building. No deflection detail is incorporated.

System typically incorporates SFS floor joists at coincident positions to stud set out to robustly tie all the floors, roof and walls together forming the structure. Kingframe load bearing systems are BBA approved up to three storeys.

Description

The Kingframe Steel Framing System (SFS) is manufactured from light gauge galvanised steel. The system consists of C-shaped studs and U-shaped tracks designed on a project specific basis to form the inner leaf of an external façade.


SFS has been extensively used in construction projects covering residential flats, apartments, healthcare and educational developments, commercial developments, public buildings and industrial properties in both infill and oversail arrangements.


Kingspan SFS system utilises our unique slotted stud ends in conjunction with plain U-track at head to achieve a deflection detail for Infill systems. Alternative standard details are available to achieve deflection head requirements such as Deflection Head Bracket (DHB) ancillary item.


Quality and Durability:

Kingspan insulated panels are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, complying with:

  • BS EN ISO 14001 panels are manufactured under Environmental Management System Certification.
  • BS EN ISO 9001 standard, ensuring long term reliability and service life.
  • BS EN ISO 50001 Energy Management System Certification.
  • BS EN ISO 45001 Occupational Health and Safety Certification.
  • BS EN ISO 37301 Compliance Management Systems
  • CE marked to BS EN 14509: 2013.

General information

Color

Grey

Finish

Galvanized

Material

Steel

Length

70 mm

100 mm

125 mm

150 mm

200 mm

Show more

Warranty description

Other

Uniclass

Pr_20_76_51_21 Cold-formed galvanized steel sectionsPrimary
Pr_20_65_60_48 Light-gauge steel frame panels

CAWS

G10/170 Cold-formed galvanized steel

G10/30 Cold-formed galvanized steel

Product range

Structural steel / SFS

Specification data - Cold-formed galvanized steel sections

Primary components

'C' section stud, 70 x 50 x 1.5 mm.

Guidance for specification option:

Mass: 2.09 kg/m.

'C' section stud, 70 x 50 x 2.0 mm.

Guidance for specification option:

Mass: 3.48 kg/m.

'U' section track, 74 x 55 x 1.5 mm.

Guidance for specification option:

Mass: 2.10 kg/m.

'U' section track, 74 x 69 x 1.8 mm.

Guidance for specification option:

Mass: 2.89 kg/m.

'U' section track, 74 x 69 x 2.0 mm.

Guidance for specification option:

Mass: 3.2 kg/m.

Ancillary components

Angles.

Guidance for specification option:

Size options:

50 x 50 x 70/100/150/200/300 mm.

50 x 50 x 3000 mm.

100 x 50 x 3000 mm.

150 x 100 x 3000 mm.

All available in 2 mm thickness.

Cleats.

Guidance for specification option:

Size options:

50 x 50 x 70/100/150/200/300 mm.

50 x 50 x 3000 mm.

100 x 50 x 3000 mm.

150 x 100 x 3000 mm.

All available in 2 mm thickness.

Brackets.

Guidance for specification option:

Size options:

60 x 80 x 95 x 2.4 mm.

135 x 80 x 95 x 2.8 mm.

'Z' Bars.

Guidance for specification option:

40 x 40 x 40 x 3000 mm.

Flat straps.

Guidance for specification option:

Size options:

100 x 1.2 mm.

38 x 0.9 mm. 

Manufacturer guidance

Standard: To BS EN 10346.

Designation: S275GD+Z275.

Material

-

Standard

To BS EN 10346.

Designation

S390GD+Z275.

Thickness

As primary components.

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

03/S034

Similar products from Kingspan Insulated Panels

Kingframe LEC Steel Frame System

Kingframe LEC Steel Frame System

LEC Mezzanine Floor

LEC Mezzanine Floor

Multibeam LEC Purlin

Multibeam LEC Purlin