Isolating hanger for the construction of soundproof ceilings (reduces airbourne and impact noise) with as little as 5mm of ceiling height loss.
Soundproof ceiling space saving acoustic hangers for house conversion to flats, new builds and renovations of houses and flats. Shops, restaurants and other commercial soundproofing applications.
Isolating acoustic hanger for the construction of soundproof ceilings (reduces airborne and impact noise) with as little as 5 mm of ceiling height loss.
An isolating ceiling mount which significantly reduces transmission of noise from the floor above, but only loses as little as 5 mm of ceiling height; all work is done from the room below.
The Oscar Iso-Mount Type1 space saving acoustic hanger is a three-component assembly: the metal 'L' bracket screws to the sides of the joists, a rubber block sits in position on the 'L' bracket and breaks the path of vibration to the third component, a metal saddle that is held in position on the rubber block.
For new builds or retrofits, Oscar Iso-Mounts acoustic hangers are screw fixed to the sides of joists which allows for vertical adjustment and the minimum of ceiling height loss, typically 5–6mm: just enough for the ceiling boards to not directly touch the joists. The ceiling soundproofing is finished with two layers of 12.5mm thick plasterboard, which are screw fixed to metal channels or timber batts fixed to the mounts.
Iso-Mount Type1 space saving acoustic hangers independent acoustic site testing demonstrates comfortable compliance with Building Regulations (E&W) Approved Document E requirements for airborne and impact sound. Copies of tests are available from Oscar Acoustics.
View Iso-Mount Type1 installation guide video here: https://www.oscar-acoustics.co.uk/acoustic-solutions/soundproofing-products/oscar-iso-mount-type-1
Features and benefits:
Can be used in conjunction with:
Finish | Galvanized |
Material | Steel Guidance for specification option: Mild. Rubber |
Shape | Other Guidance for specification option: Distinctive patented design. |
Length | 56 mm |
Width | 48 mm |
Height | 97 mm |
Warranty description | Manufacturer guidanceAcoustic test data and fire test report available: EN 1365-2:2014 load bearing floor. |
Uniclass | |
CAWS | K10/245 Ceiling lining on timber K10/220 Proprietary suspended ceiling system K10/25 Ceiling lining on timber K10/50 Suspended ceiling system on metal framing |
Product range |
Standard | Acoustic test data and fire test report available: EN 1365-2:2014 load bearing floor.Guidance for specification option: Consult manufacturer for details. |
Material | Mild steel and rubber. |
Component types | |
Ceiling hangers | Acoustic ceiling mount.Guidance for specification option: Three-component assembly: the metal 'L' bracket screws to the sides of the joists, a rubber block sits in position on the 'L' bracket and breaks the path of vibration to the third component, a metal saddle that is held in position on the rubber block. |
Fire rating | 90 minutes (using two layers of 15 mm Fireline plasterboard and 100 mm Rockwool insulation). Guidance for specification option: The Iso-Mount Type1 achieved over a 90-minute rating for fire resistance using two layers of 15 mm Fireline plasterboard and 100 mm Rockwool insulation. See BRE fire test report P112840-1000 for further details. |
Loading | 18 kg (maximum). Guidance for specification option: Spaced evenly at 3 x Iso-Mounts per square metre the maximum loading per square metre is 54 kg. |
Sound insulation | Exceeds Building Regulations (E&W) Approved Document E requirements for airborne and impact sound. Guidance for specification option: Copies of tests are available from Oscar Acoustics. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidanceCan effectively lower the carbon footprint of a building project by sequestering rich stores of carbon for the life of the structure or application. |
Recyclability | 66% |