NBS Source
I'm a manufacturer

Description

One layer of Gyproc FireLine 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2400mm.

General information

Finish

-

Manufacturer guidance

To achieve the specified performances, the system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.

Material

Gypsum

Metal

Plasterboard

Steel

Glass mineral wool

Height

2400 mm

Uniclass

Ss_25_25_45_35 Gypsum board wall lining systemsPrimary

CAWS

K10/155 Wall lining system (metal studs)

K10/30 Metal stud

Product range

Wall linings / GypLyner Independent

Specification data - Gypsum board wall lining systems

Support

Base channel: Gypframe 50 FEC 50 Folded Edge Standard Floor & Ceiling Channel.
Head channel: Gypframe 50 FEC 50 Folded Edge Standard Floor & Ceiling Channel.
Stud: Gypframe 48 I 50 'I' Stud.
Abutments and openings: Gypframe 48 S 50 'C' Stud.

Insulation

Insulation, Layer 1: 50mm Isover Steel Frame Infill Batt.

Linings

Board side 1, Layer 1: Gyproc FireLine 12.5mm.

Fasteners

Screws side 1, Layer 1: British Gypsum Drywall Screws 25mm.

Joint treatment

Fixing strap: Gypframe GFS1 Fixing Strap.
Fixing T: Gypframe GFT1 Fixing 'T'.

Finish

To achieve the specified performances, the system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.

System accessories

Sealant: Gyproc Sealant.
Thermal sealant: Gyproc Sealant.

Execution

Please review details on the British Gypsum website at: https://www.british-gypsum.com/Specification/White-Book-Specification-Selector/wall-linings/GypLyner-Independent/B216025-A-EN#details

Fire resistance

BS EN 1364-1, 60 / 30 Integrity / Insulation

Strength grade

BS 5234-2, Medium duty (MD)

Partition height

2400mm

Background

Background: Steel Clad External Wall

Similar products from British Gypsum

DriLyner Dab - BASIC (A) (EN)

DriLyner Dab - BASIC (A) (EN)

DriLyner Dab - BASIC (B) (EN)

DriLyner Dab - BASIC (B) (EN)

DriLyner Dab - BASIC (C) (EN)

DriLyner Dab - BASIC (C) (EN)

DriLyner Dab - BASIC (D) (EN)

DriLyner Dab - BASIC (D) (EN)

DriLyner Dab - BASIC (E) (EN)

DriLyner Dab - BASIC (E) (EN)

DriLyner Dab - BASIC (F) (EN)

DriLyner Dab - BASIC (F) (EN)

DriLyner Dab - RF-PIR (A) (EN)

DriLyner Dab - RF-PIR (A) (EN)

DriLyner Dab - RF-PIR (B) (EN)

DriLyner Dab - RF-PIR (B) (EN)

DriLyner Dab - RF-PIR (C) (EN)

DriLyner Dab - RF-PIR (C) (EN)

DriLyner Dab - RF-PIR (D) (EN)

DriLyner Dab - RF-PIR (D) (EN)