NBS Source
List your products

GGL INTEGRA® Elect/Solar centre-pivot roof window

Third party certifications:
  • QA Certificate

    Certificate type

VELUX Company Ltd

Fully integrated operated, centre pivot roof window for roof pitches between 15–90°.

Jump to:
+44 (0)1592 778225 www.velux.co.uk
Description

Fully integrated operated, centre pivot roof window for roof pitches between 15–90°.

Features:

  • Fully integrated, pre-installed motor.
  • Ideal for out-of-reach areas.

Operation:

  • Simple, convenient wall switch to operate the windows.
  • Rain sensor closes window automatically in the event of rain.

Warranty:

  • Ten-year guarantee for windows and panes.
  • Three-year guarantee for electrical items and blinds.

General information
Color

white paint color NCS 0500-N

Features

Electrical pivot hung roof window

Material

Wood

Size

470 x 980 mm

Uniclass 2015
Wood frame roof window units (Pr_30_59_98_97)Primary
Specification data - Wood frame roof window units
Product Reference

GGL INTEGRA® electric, centre-pivot roof window

Roof pitch

Insert requirements.

Window -
Window code

GGL CK02

Standard size 550 mm wide x 778 mm high, effective daylight area 0.22 m².

GGL CK04

Standard size 550 mm wide x 978 mm high, effective daylight area 0.29 m².

GGL CK06

Standard size 550 mm wide x 1178 mm high, effective daylight area 0.37 m².

GGL FK06

Standard size 660 mm wide x 1178 mm high, effective daylight area 0.47 m².

GGL MK04

Standard size 780 mm wide x 978 mm high, effective daylight area 0.47 m².

GGL MK06

Standard size 780 mm wide x 1178 mm high, effective daylight area 0.59 m².

GGL MK08

Standard size 780 mm wide x 1398 mm high, effective daylight area 0.72 m².

GGL PK08

Standard size 942 mm wide x 1398 mm high, effective daylight area 0.92 m².

GGL PK10

Standard size 942 mm wide x 1600 mm high, effective daylight area 1.07 m².

GGL SK06

Standard size 1140 mm wide x 1178 mm high, effective daylight area 0.95 m².

GGL UK04

Standard size 1340 mm wide x 978 mm high, effective daylight area 0.91 m².

GGL UK08

Standard size 1340 mm wide x 1398 mm high, effective daylight area 1.40 m².

GGL CK01

Non-standard size 550 mm wide x 698 mm high, effective daylight area 0.19 m².

GGL FK04

Non-standard size 660 mm wide x 978 mm high, effective daylight area 0.37 m².

GGL FK08

Non-standard size 660 mm wide x 1398 mm high, effective daylight area 0.58 m².

GGL MK10

Non-standard size 780 mm wide x 1600 mm high, effective daylight area 0.84 m².

GGL MK12

Non-standard size 780 mm wide x 1800 mm high, effective daylight area 0.96 m².

GGL PK25

Non-standard size 942 mm wide x 550 mm high, effective daylight area 0.27 m².

GGL PK04

Non-standard size 942 mm wide x 978 mm high, effective daylight area 0.60 m².

GGL PK06

Non-standard size 942 mm wide x 1178 mm high, effective daylight area 0.75 m².

GGL SK01

Non-standard size 1140 mm wide x 698 mm high, effective daylight area 0.48 m².

GGL SK08

Non-standard size 1140 mm wide x 1398 mm high, effective daylight area 1.16 m².

GGL SK10

Non-standard size 1140 mm wide x 1600 mm high, effective daylight area 1.35 m².

GGL UK10

Non-standard size 1340 mm wide x 1600 mm high, effective daylight area 1.63 m².

Finish -
Internal frame and sash

White Painted – Code 2

Lacquered Pine – Code 3

External cladding

Grey aluminium; colour reference NCS S-7500-N - Code 0

Untreated copper – Code 1

Titanium zinc – Code 3

Painted aluminium – Code 8, colour

Insert RAL or NCS colour reference.

Glazing

6821U

6.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings.

6621U

6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings.

7021U

6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane.

Blinds, Awning and Shutter -
Type

Not required

Blackout blind – Code DML

External awning blind – Code MML

External shutter – Code SML

Light dimming energy blind – Code FMC

Pleated blind – Code FML

Roller blind – Code RML

Colour

Not applicable

As schedule

Refer to VELUX Blinds and Shutters brochure for available colours and patterns.

Operation

Electrical

Energy efficiency installation collars

Insulation Collar – Code BDX 2000

Not compatible with EDN and EDJ flashings. Includes BFX.

Insulation Collar – Code BDX 2000F

Compatible with EDN and EDJ flashings only. Includes BFX.

Underfelt Collar – Code BFX 1000

Vapour Barrier Collar – Code BBX 0000

Flashing

EDL

For standard installation in slate up to 8 mm thick; roof pitch 15–90°.

EDN

For recessed installation in slate up to 8 mm thick; roof pitch 20–90°.

EDW

For standard installation in tiles up to 120 mm in profile; roof pitch 15–90°. Also for interlocking slate, thatch and profile sheeting.

EDJ

For recessed installation in tiles up to 90 mm in profile; roof pitch 20–90°.

EDP

For standard installation in plain tiles up to 14 mm thick; roof pitch 25–90°.

ZWC

For standard installation where an on-site flashing is required; roof pitch 15-90°.

Accessories

Not required

VELUX ACTIVE with NETATMO – Code KIX 300

Smart sensor based operation and smartphone control.

Product Options

Glazing:

- Code 6821U:

  • Thermal performance (U-value): 1.1 W/m²K.
  • Sound insulation (Rw): 35 dB.
  • Light Transmittance (Tv): 0.71.
  • Total solar energy transmittance (g): 0.52.

- Code 6621U:

  • Thermal performance (U-value):1.0 W/m²K.
  • Sound insulation (Rw): 37 dB.
  • Light Transmittance (Tv): 0.71.
  • Total solar energy transmittance (g): 0.52.

- Code 7021U:

  • Thermal performance (U-value): 1.3 W/m²K.
  • Sound insulation (Rw): 35 dB.
  • Light Transmittance (Tv): 0.68.
  • Total solar energy transmittance (g): 0.46.

Energy efficiency installation collars:

  • Insulation collar – Code BDX: Optimizes the insulation around the window frame by preventing heat loss and eliminating cold bridges. BDX 2000 variant Includes underfelt collar BFX.
  • Underfelt collar – Code BFX: Ensures a weathertight seal between the roof window and the roof.
  • Vapour barrier collar – Code BBX: Provides vapour control and air permeability seal.

Flashing:

Flashings are available in materials and finishes to match roof window cladding.

  • Code EDL: For standard installation into slate and flat roofing materials up to 8 mm thick. Not suitable for interlocking slate.
  • Code EDN: For recessed installation into slate and flat roofing materials up to 8 mm thick. Not suitable for interlocking slate.
  • Code EDW: For standard installation into flat and profiled roofing materials up to 120 mm thick, including profiled sheeting and interlocking slates.
  • Code EDJ: For recessed installation into flat and profiled roofing materials up to 90 mm thick, including profiled sheeting and interlocking slates.
  • Code EDP: For standard installation into plain tiles up to 14 mm thick.
  • Code ZWC: Window profile set to be used in conjunction with on-site weathering for non-standard roofing materials. For further details please contact VELUX.

Digital objects
PlatformCompatibleVersionCertified to
Revit
- 4 2.1
Download now from NBS National BIM Library
Third party certifications
  • CE marked: EN 14351-1:2006 + A2:2016
Similar products from VELUX Company Ltd