Verified by manufacturer 22 days ago
BBA Agrément Certificate
Certificate type
BBA Agrément Certificate
Certificate type
BBA Agrément Certificate
Certificate type
BBA Agrément Certificate
Certificate type
EPD
Certificate type
EPD
Certificate type
Conservation style, manually operated, centre pivot roof window. Black external finish.
For roof pitches between 15–90°, depending on roofing material.
Features and benefits:
Window size code:
Finishes:
Glazing:
- Code 70:
6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane.
Color | White |
Finish | Painted Guidance for specification option: Internal frame and sash is White painted as standard or comes in Lacquered natural pine. External cladding available in black aluminium, colour reference NCS S-9000-N (nearest RAL 9005) - Code 5 Lacquered |
Material | Pine Guidance for specification option: frames Aluminium Guidance for specification option: cladding |
Width | 550 mm 660 mm 780 mm 1340 mm |
Height | 978 mm 1178 mm 1398 mm |
Warranty description | Ten year Guidance for specification option: For window and pane Three year Guidance for specification option: For blinds |
Uniclass | |
CAWS | L10/480 Roof windows |
Product range |
Classification data | |
Product performance | |
Whole window U-value | 1.3 W/m²K. |
Glazing or infill | |
Composition | Argon filled cavity. |
Hardware | Complete with relevant flashing, insulation and underfelt collars. |
Operation | |
Type | Manually operated. Guidance for specification option: One pull of top control bar allows background ventilation whilst the window remains securely closed. One further pull opens the window. Rotates 180° and locks in place for ease of cleaning of the outer pane |
Fixing features | Installation collars e.g. insulation, underfelt, vapour barrier. |
Accessories | None. Insect screen. Manual – Codes ZCT 200K ZOZ 085 - Control rod and adaptor. |
Execution | Fixing of wood frames. |
Internal frame and sash | White painted. Guidance for specification option: Standard. Lacquered natural pine. |
External cladding | Black aluminium; colour reference NCS S-9000-N (nearest RAL 9005) - Code 5. |
Roof pitch | Guidance for specification option: Insert requirements. |
Window size code | GGL CK04 SD5N2. Guidance for specification option: Conservation Roof Window System - Recessed installation - For slates up to 8 mm thick, minimum roof pitch 20°. GGL CK06 SD5N2. Guidance for specification option: Conservation Roof Window System - Recessed installation - For slates up to 8 mm thick, minimum roof pitch 20°. GGL FK06 SD5N2. Guidance for specification option: Conservation Roof Window System - Recessed installation - For slates up to 8 mm thick, minimum roof pitch 20°. GGL MK06 SD5N2. Guidance for specification option: Conservation Roof Window System - Recessed installation - For slates up to 8 mm thick, minimum roof pitch 20°. GGL MK08 SD5N2. Guidance for specification option: Conservation Roof Window System - Recessed installation - For slates up to 8 mm thick, minimum roof pitch 20°. GGL UK04 SD5N2. Guidance for specification option: Conservation Roof Window System - Recessed installation - For slates up to 8 mm thick, minimum roof pitch 20°. GGL CK04 SD5P2. Guidance for specification option: Conservation Roof Window System – Standard installation - For plain tiles up to 14 mm thick, minimum roof pitch 25°. GGL CK06 SD5P2. Guidance for specification option: Conservation Roof Window System – Standard installation - For plain tiles up to 14 mm thick, minimum roof pitch 25°. GGL FK06 SD5P2. Guidance for specification option: Conservation Roof Window System – Standard installation - For plain tiles up to 14 mm thick, minimum roof pitch 25°. GGL MK06 SD5P2. Guidance for specification option: Conservation Roof Window System – Standard installation - For plain tiles up to 14 mm thick, minimum roof pitch 25°. GGL MK08 SD5P2. Guidance for specification option: Conservation Roof Window System – Standard installation - For plain tiles up to 14 mm thick, minimum roof pitch 25°. GGL UK04 SD5P12. Guidance for specification option: Conservation Roof Window System – Standard installation - For plain tiles up to 14 mm thick, minimum roof pitch 25°. GGL CK04 SD5W2. Guidance for specification option: Conservation Roof Window System – Standard installation - For tiles up to 120 mm thick in profile, minimum roof pitch 15°. GGL CK06 SD5W2. Guidance for specification option: Conservation Roof Window System – Standard installation - For tiles up to 120 mm in profile, minimum roof pitch 15°. GGL FK06 SD5W2. Guidance for specification option: Conservation Roof Window System – Standard installation - For tiles up to 120 mm in profile, minimum roof pitch 15°. GGL MK06 SD5W2. Guidance for specification option: Conservation Roof Window System – Standard installation - For tiles up to 120 mm in profile, minimum roof pitch 15°. GGL MK08 SD5W2. Guidance for specification option: Conservation Roof Window System – Standard installation - For tiles up to 120 mm in profile, minimum roof pitch 15°. GGL UK04 SD5W2. Guidance for specification option: Conservation Roof Window System – Standard installation - For tiles up to 120 mm in profile, minimum roof pitch 15°. GGL CK04 SD5J2. Guidance for specification option: Conservation Roof Window System - Recessed installation - For tiles up to 90 mm in profile, minimum roof pitch 20°. GGL CK06 SD5J2. Guidance for specification option: Conservation Roof Window System - Recessed installation - For tiles up to 90 mm in profile, minimum roof pitch 20°. GGL FK06 SD5J2. Guidance for specification option: Conservation Roof Window System - Recessed installation - For tiles up to 90 mm in profile, minimum roof pitch 20°. GGL MK06 SD5J2. Guidance for specification option: Conservation Roof Window System - Recessed installation - For tiles up to 90 mm in profile, minimum roof pitch 20°. GGL MK08 SD5J2. Guidance for specification option: Conservation Roof Window System - Recessed installation - For tiles up to 90 mm in profile, minimum roof pitch 20°. GGL UK04 SD5J2. Guidance for specification option: Conservation Roof Window System - Recessed installation - For tiles up to 90 mm in profile, minimum roof pitch 20°. |
Type | Not required. Blackout blind. Guidance for specification option: Code DKL Blackout energy blind. Guidance for specification option: Code FHC Duo blackout blind. Guidance for specification option: Code DFD External awning blind. Guidance for specification option: Code MHL External roller shutter. Guidance for specification option: Code SHL Flying pleated blind. Guidance for specification option: Code FHL Insect screen. Guidance for specification option: Code ZIL Roller blind. Guidance for specification option: Code RFL Roman blind. Guidance for specification option: Code FHB Solar powered blackout blind. Guidance for specification option: Code DSL Solar powered blackout energy blind. Guidance for specification option: Code FSC Solar powered external awning blind. Guidance for specification option: Code MSL Solar powered external roller shutter. Guidance for specification option: Code SSL Solar powered pleated blind. Guidance for specification option: Code FSL Solar powered roller blind. Guidance for specification option: Code RSL Venetian blind. Guidance for specification option: Code PAL |
Colour | Not applicable. As schedule. Guidance for specification option: See VELUX Blinds and Shutters brochure for available colours and patterns. |
Exterior sunscreen | Not required. MHL Manual Awning blind, colour 5060. |
Energy efficient installation | Insulation Collar – Code BDX. Guidance for specification option: Included in package. Underfelt Collar – Code BFX 1000. Guidance for specification option: Included in package. Vapour Barrier Collar. Guidance for specification option: BBX Code 0000 |
Contains Red List materials | No |
Material | Pine Guidance for specification option: frames Aluminium Guidance for specification option: cladding |
Recyclability | Partially Recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 20 % |
Expected Life | 25 year |
GBL Low Pitch, Centre-Pivot Roof Window
GCL Heritage conservation roof window
GDL Roof Balcony
GEL Roof Terrace
GGL Centre-Pivot Roof Window
GGL Electric/ Solar Centre-Pivot Roof Window
GGL Solar Powered, Centre-Pivot Roof Window
GGLS 3in1 Centre-Pivot Timber Roof Window
GIL Fixed Sloped Additional Lower Element
GPL Manually Operated, Top-Hung Roof Window, Conservation Style