Firemaster Extra 0.5/ 0.5 mm Internal/ External Gauge - 75 mm Thickness
Internal wall and ceiling metal insulated sandwich panel.
The Firemaster Range of internal sandwich wall and ceiling panels is suited to the construction of non-load-bearing internal partition walls and ceilings.
What We Do
EuroClad are an international supplier of architectural metal building solutions to the construction industry.
We manufacture highly engineered building envelope products including roof and wall cladding systems, insulated sandwich panels and architectural flashings and fabrications.
Quality & Durability
Our Eurobond Panels complying with:
Fire Performance
The Firemaster Range of wall and ceiling panels offers a Euroclass A2-s1, d0 Reaction to Fire when tested and classified to BS EN 13501-1:2018.
Firemaster Extra can also offer fire resistance performances from 60 minutes up to 4 hours Insulation and Integrity (to BS EN 1364-1:2015) depending on thicknesses and orientation. Specific performances should be verified by our Technical Team on a project-by-project basis, to the correct standards.
Firemaster
The Firemaster Range of internal sandwich wall and ceiling panels is suited to the construction of non load-bearing internal partition walls and ceilings. A food-safe laminate option is also available that provides a smooth, anti-static internal surface for cleanroom environments.
The Firemaster Range is available in 1200 mm width as standard with a range of surface profiles - flat, mini-bead or equibead (Firemaster Extra only). Wall panels are available with a V-groove profile for vertical and horizontal installation.
Firemaster Ceiling available for ceiling installation.
Features and benefits:
Sustainability:
The Euroclad Group is built on a foundation with sustainability at the core, the company has been a keen advocate of environmental standards achieving BES 6001, and through the Planet Passionate sustainability programme, we continue to push even further in achieving ambitious sustainability targets.
In 2024, Euroclad was awarded a Gold Medal by EcoVadis, the world's largest provider of sustainability ratings to assessed businesses.
Color | Other |
Finish | Coated |
Material | Steel Stone wool |
Shape | Rectangle |
Length | 1800 mm Guidance for specification option: Minimum length. 12500 mm Guidance for specification option: Maximum length. Bespoke |
Width | 1200 mm |
Height | 75 mm 100 mm 125 mm 150 mm 175 mm |
Uniclass | |
CAWS | K40/20 Board-suspended ceiling systems K40/135 Board-suspended ceiling system H43/10 Metal insulating sandwich panel H43/120 Metal insulating sandwich panel |
Classification data | |
Standard | To EN 14509:2013. |
Panels | Factory-assembled insulating sandwich panels. |
Panel construction | |
Panel external face | |
Material | Steel. |
Profile | Flat. Mini-bead. Equibead. |
Thickness | 0.5 mm. |
Panel internal face | |
Material | Steel. |
Profile | As external profile. |
Thickness | 0.5 mm. |
Core insulation | Mineral wool lamella. Guidance for specification option: Stone wool.
|
Panel dimensions | |
Length | Guidance for specification option: Panel lengths 1800–12 500 mm, consult manufacturer and insert requirements. |
Cover width | 1200 mm. |
Thickness | 75 mm. |
Joint type | |
Side or vertical | Interlocking. Guidance for specification option: Vertical orientation. Butt with cover cap. Guidance for specification option: Horizontal orientation. |
End or horizontal | Butt with cover cap. Guidance for specification option: Vertical orientation. Interlocking. Guidance for specification option: Horizontal orientation. |
Finish as delivered | |
Outer skin | |
Material | Tata Steel Colorcoat Prisma. |
Inner skin | |
Material | Tata Steel Colorcoat® PE 25. Tata Steel Advantica® L Control (FSL). ArcelorMittal® Estetic Standard. |
Colour | Guidance for specification option: Consult manufacturer and insert requirements. |
Fire performance | |
Fire resistance | To EN 13501-2, NPD. Guidance for specification option: Firemaster Extra can also offer fire resistance performances from 60 minutes up to four hours insulation and integrity (to BS EN 1364-1:2015) depending on thicknesses and orientation. Consult manufacturer and insert requirements. |
Weight | 16.37 kg/m². |
Thermal insulation (U-value) | 0.51 W/m²·K. |
Third-party certification | CE marked. |
Reaction to fire | To BS EN 13501-1: 2018, A2-s1,d0. |
Material | Steel Stone wool |