Façade system with up to 30 minutes of fire protection (E, EW & EI).
Compatible with all vertical facades and skylights.
Multi-purpose fire-resistant facades for resistance classes EI30 and EW30. Identical internal and external face widths allow these facades to be combined seamlessly with the standard Schüco FW 50+ and FW 60+ facade systems.
Features and benefits:
Standards:
Color | Silver Other |
Finish | Powder-coated Anodized |
Material | Aluminium Glass |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | H11/110 Curtain walling |
Classification data | |
Framing | |
Frame members | Aluminium curtain wall frame sections, polyester powder-coated. Guidance for specification option: Insert colour requirements. Aluminium curtain wall frame sections, anodized. |
Frame accessories | Manufacturer guidanceConsult manufacturer for options and insert requirements, or omit. |
Fasteners | Manufacturer's standard. |
Cladding units | |
Glass units | Manufacturer guidanceInsert requirements, including thickness 13–52 mm thick. |
Glazing accessories | Manufacturer guidanceInsert requirements or omit. |
Fasteners | Manufacturer's standard. |
Perimeter seals | Manufacturer's standard. |
System accessories | Manufacturer guidanceConsult manufacturer for options and insert requirements, or omit. |
Face width | 60 mm. Guidance for specification option: Minimum. |
Thermal transmittance (U-Value) | Manufacturer guidanceInsert requirements or consult manufacturer for values. Uf value of frame: ≥ 1.1 W/m²K. |
Burglar resistance | Manufacturer guidanceInsert requirements; to EN 1627, up to RC 2. |
Air permeability | To EN 12152, Class AE. |
Watertightness | To EN 12154, Class RE 1200. |
Resistance to wind load | To EN 12179, 1.2 kN/m². Guidance for specification option: Permissible load (in kN/m²), Positive wind load: +1.2, negative wind load: -1.2 Increased load (in kN/m²), Positive wind load: +1.8, negative wind load: -1.8. |
Impact resistance | To EN 14019, I5 / E5. |
Fire resistance | To EN 13501-2, F30, G30, EI30 and EW30. |
Label | Schueco ‘IoF’ ID tag with QR code. Guidance for specification option: Internet of facades (IoF) ID tag with unique QR code linked to the product data, ongoing maintenance instructions and installation records. |
Country of material origin | United Kingdom |
Material | Aluminium Glass |
Add-On Construction (AOC)
AF LDC 50 - Aluminium Facade
Blast-resistant stick curtain walling façade system - FW 60+ XR
Concealed vent stick curtain walling façade system - FWS 60 CV
Fire-resistant Steel Stick Curtain Walling Façade System - VISS Fire
Fire-resistant stick curtain walling façade system - FW 50+ BF
Fire-resistant stick curtain walling façade system - FW 50+ FR 60
Highly Thermally Insulated Steel Stick Curtain Walling Façade System - VISS 50
Highly Thermally Insulated Steel Stick Curtain Walling Façade System - VISS 60
Slimline Panorama design stick curtain walling façade system - FWS 35 PD