Verified by manufacturer 15 days ago
Design .40 - With actuator BF 230-TN (BFL, BFN 230-T)
DoP
Certificate type
Hygiene requirements to VDI 6022
Certificate type
Certificate of constancy of performance
Certificate type
EPD
Certificate type
A multi-blade fire damper for HVAC ductwork.
Additional applications may be available, please reference product Technical Specifications for more detail.
A Fire Damper is used to prevent fire and reduce smoke spreading from one compartment to another through the air ductwork system which may penetrate fire separating walls and floors.
Features and benefits:
Color | Silver |
Finish | Galvanized |
Material | Steel |
Shape | Rectangle Square |
Length | 150 mm |
Width | 300 mm 315 mm 355 mm 400 mm 450 mm |
Height | 200 mm 250 mm 280 mm 300 mm 315 mm |
Warranty description | Two year |
Uniclass | |
CAWS | U90/443 Dampers, fire/ smoke |
Standard | |
Fire dampers | To EN 15650. |
Test | To EN 1366-2. |
Classification | To EN 13501-3. |
Aerodynamic performance | To EN 1751.Guidance for specification option: Damper body: Class B; Damper blade: Class 3. |
Arrangement | Multiblade. |
Classification | EIS90.EIS120.Manufacturer guidanceRefer to the manufacturer's literature for placement and installation details to achieve the required fire resistance values. |
Material | Zinc-coated steel. |
Accessories | Microswitches for status indication.Guidance for specification option: Signalisation of damper blades position "OPEN" and "CLOSED". |
Fusible links | |
Fusing temperature | 72°C.Guidance for specification option: As standard. 95°C.120°C.140°C. |
Spare fusible links | Manufacturer guidanceInsert requirements or omit. |
Dimensions | Manufacturer guidance
Due to the nature of multi-bladed dampers, bespoke sizing is not available; consult manufacturers technical specification for a full list of available sizes and insert requirements. |
Actuator | Belimo BF 230-TN (BFL, BFN 230-T). Guidance for specification option: 230 V a.c. Manufacturer guidanceFire dampers are equipped with Belimo spring return actuators with thermoelectric activation device BAT. The spring return actuator types are BFL, BFN or BF depending on the damper size. |
Grille | Not required. Guidance for specification option: Installation as part of an air duct. 1 no. grille. Guidance for specification option: Following duct on one side. 2 no. grilles. Guidance for specification option: Fire shutter without following air duct. |
Duct connection | Mandik FFDM breakaway joint. Guidance for specification option: FFDM allows a breakaway connection between a duct and fire damper according to DW/145. The FFDM is a flanged breakaway joint with a plastic pad which will melt at 80°C, allowing the duct to break away from the damper and ensure the dampers integrity is maintained. Refer to FFDM – Technical specifications for options and insert requirements. Breakaway joint (supplied by others). Guidance for specification option: Insert requirements. Manufacturer guidanceBreakaway joints are a required accessory for the fire dampers. These joints are required on both sides of the damper. |
Material | Steel |
Platform | Compatible | Version |
---|---|---|
- | 1 |
FDMA - Rectangular EIS Fire Damper (≤1600x1000mm) - Manual/Motorised - Fire Damper
FDMB - Rectangular EIS Fire Damper (≤1000x500mm) - Manual/Motorised - Fire Damper
FDMQ - Rectangular EIS Fire Damper (≤1500x800mm) - Manual/Motorised - Fire Damper
FDMQ 120 - Rectangular EIS Fire Damper (≤1500x800mm) - Manual/Motorised - Fire Damper
FDMQ 180 - Rectangular EIS Fire Damper (≤1500x800mm) - Manual/Motorised - Fire Damper
FDMR - Circular EIS Fire Damper (Ø100-800mm) - Manual/Motorised - Fire Damper
FDMR 180 - Circular EIS Fire Damper (Ø200-800mm) - Manual/Motorised - Fire Damper
FDMR 60 - Circular EIS Fire Damper (Ø100-400mm) - Manual/Motorised - Fire Damper