Design .01 Manual and thermal
Type Examination Certificate
Certificate type
Hygiene requirements to VDI 6022
Certificate type
Certificate of Conformity
Certificate type
DoP
Certificate type
UK Conformity Assessed (UKCA)
Certificate type
Certificate of constancy of performance
Certificate type
EPD
Certificate type
A single blade fire damper for HVAC ductwork.
Fire dampers are suitable for installation in vertical and horizontal passages of fire-separating constructions. The fire damper can be installed into:
Additional applications may be available, please reference product Technical Specifications for more detail.
A Fire Damper is used to prevent fire and reduce smoke spreading from one compartment to another through the air ductwork system which may penetrate fire separating walls and floors.
Features and benefits:
Color | Silver |
Finish | Galvanized |
Material | Steel Calcium silicate |
Shape | Rectangle Square |
Length | 375 mm |
Width | 100 mm 110 mm 125 mm 140 mm 150 mm |
Height | 100 mm 110 mm 125 mm 140 mm 150 mm |
Uniclass | |
CAWS | U90/443 Dampers, fire/ smoke |
Standard | |
Fire dampers | To BS EN 15650. |
Test | To BS EN 1366-2. |
Classification | To BS EN 13501-3. |
Aerodynamic performance | To BS EN 1751.Guidance for specification option: Damper body, for size: A<160 or B<160 Class B; A≥160 or B≥160 Class C. Damper blade: Class 2. |
Arrangement | Single-blade. |
Classification | EIS30.EIS45.EIS60.EIS90.EIS120.Manufacturer guidanceRefer to the manufacturer's literature for placement and installation details to achieve the required fire resistance values. |
Material | Zinc-coated steel. |
Fusible links | |
Fusing temperature | 72°C.Guidance for specification option: As standard. 104°C.147°C. |
Spare fusible links | Manufacturer guidanceInsert requirements or omit. |
Dimensions | Manufacturer guidanceConsult manufacturer's literature for performance details and insert requirements.
|
Actuator | Mandik. |
Control module | Not required. Communication and control module MDCM. Manufacturer guidanceThe MDCM damper control module is connected on a bi-directional communication loop back to a control panel, typically located at the FCC. This accessory is only required with MANDIK control systems. |
Cladding | Not required. Protective cladding boards. Manufacturer guidanceProtective cladding boards must be used as part of the penetration filling of installation with ablative coated batt. Boards are made of PROMATECT-H, thickness 10 or 15 mm according to the damper size (SUPALUX, thickness 9 or 15 mm can be used as an alternative). |
Frame | Not required. Reinforcing frame VRM2-B. Manufacturer guidanceIf the damper is installed outside the fire separation construction with insulation from ISOVER and fire resistance is ≥ EI 90 S, VRM2-B reinforcement frame must be used. |
Duct connection | Mandik FFDM breakaway joint. Guidance for specification option: FFDM allows a breakaway connection between a duct and fire damper according to DW/145. The FFDM is a flanged breakaway joint with a plastic pad which will melt at 80°C, allowing the duct to break away from the damper and ensure the dampers integrity is maintained. Refer to FFDM – Technical specifications for options and insert requirements. Breakaway joint (supplied by others). Guidance for specification option: Insert requirements. Manufacturer guidanceBreakaway joints are a required accessory for the fire dampers. These joints are required on both sides of the damper. |
Material | Steel Calcium silicate |
Platform | Compatible | Version |
---|---|---|
- | 1 |
Type Examination Certificate
Certificate ATEX
Hygiene requirements to VDI 6022
Hygienic assessment - Fire dampers
Certificate of Conformity
Declaration of conformity ATEX
DoP
FDMB – Declaration of performance (UKCA)
DoP
FDMB – Declaration of performance (CE)
UK Conformity Assessed (UKCA)
FDMB – Certificate (UKCA)
Certificate of constancy of performance
FDMB – Certificate (CE)
EPD
Environmental Product Declaration - Fire Dampers
FDMB – Technical specifications (164/22)
Appendix ATEX
FDMB – Lightweight Wall Firebatt 30M - CID (UKCA)
FDMB – Lightweight Wall Firebatt 60M - CID (UKCA)
FDMB – Lightweight Wall Firebatt 90M - CID (UKCA)
FDMB – Lightweight Wall Gypsum - CID (UKCA)
FDMB – Remote - Lightweight Wall - CID (UKCA)
FDMB – Remote - Solid Wall - CID (UKCA)
FDMB – Shaftwall - CID (UKCA)
FDMB – Slab Firepro - CID (UKCA)
FDMB – Solid Wall Firebatt - CID (UKCA)
FDMB – Solid Wall Firepro - CID (UKCA)
FFDM – Technical specifications (137/19)
FDMA - Rectangular EIS Fire Damper (≤1600x1000mm) - Manual/Motorised - Fire Damper
FDML - EIS Multi-Blade Motorised Fire Damper (≤1000x1000mm) - Fire Damper
FDMQ - Rectangular EIS Fire Damper (≤1500x800mm) - Manual/Motorised - Fire Damper
FDMQ 120 - Rectangular EIS Fire Damper (≤1500x800mm) - Manual/Motorised - Fire Damper
FDMQ 180 - Rectangular EIS Fire Damper (≤1500x800mm) - Manual/Motorised - Fire Damper
FDMR - Circular EIS Fire Damper (Ø100-800mm) - Manual/Motorised - Fire Damper
FDMR 180 - Circular EIS Fire Damper (Ø200-800mm) - Manual/Motorised - Fire Damper
FDMR 60 - Circular EIS Fire Damper (Ø100-400mm) - Manual/Motorised - Fire Damper