Verified by manufacturer 29 days ago
Automatic swing door operator.
Automatic swing door operator suitable for lightweight internal and heavyweight external doors with high wind loads and heavy footfall. Its design is vandal-resistant, making it suitable for any location.
An electro-mechanical swing door operator which provides quiet and smooth door operation. Suitable for internal and external doors in a wide variety of applications such as retail, hotel, office, airports, stations, hospitals, schools and industrial and commercial premises.
The Gilgen unit for swing doors is capable of reliably opening and closing doors even if exposed to wind speeds of up to 80 km/h (320 Pa). For external doors, Gilgen Door Systems recommends to assume a wind pressure of at least 100 Pa 45 km/h.
Fully automatic or low energy operation complete with back check and adjustable hold open, transom mounted with standard rods/ sliding rods fitted to door leaf.
Integrated INVERSE function- If required, the FD 20 can be configured to ‘Inverse’, in order for the door to always fail in the OPEN condition. This is especially suitable for smoke ventilation or emergency escapes.
Features and benefits:
Color | Beige Black Blue Bronze Brown |
Finish | Anodized Polished Powder-coated |
Material | Aluminium Stainless steel |
Shape | Rectangle |
Length | 120 mm |
Width | 690 mm |
Height | 95 mm |
Warranty description | Two year |
Uniclass | |
CAWS | L20/55 Doorsets P21/12 Controlled door closers P21/410 Controlled door closers |
Standard | To EN 16005, DIN 18650. |
Classification grades (minimum) | |
Door closer power size | Adjustable 3–7. |
Form | Overhead, face-fixed. |
Closer functions | Controlled closing. |
Materials and finishes | |
Casings | Aluminium.Stainless steel. |
Colour | Manufacturer guidanceAny standard RAL colour. |
Door configuration | Double leaf Guidance for specification option: Door sizes two-leaf 1500 – 3200 mm. Single leaf Guidance for specification option: Door sizes single-leaf 750 – 1600 mm. Manufacturer guidanceMaximum door leaf weight of 250 kg. Maximum leaf width 1600 mm. Minimum door width 720 mm. |
Accessories | 4Safe Infra-red safety sensors. Guidance for specification option: 4Safe Infra-red safety sensors mounted on top rails of door leaves back and front to provide maximum safety. Complies with EN 16005. Flat Scan 3G Infra-red safety sensors. Guidance for specification option: Flat Scan 3G Infra-red safety sensors mounted on top rails of door leaves back and front to provide maximum safety. Complies with EN 16005. Finger protection. Guidance for specification option: Provision should also be made to protect against the potential hazards caused at the hinge or pivot stile – a suitable finger protection must be fitted to comply with EN 16005 and the Machinery Directive 2006/42/EC. Maglock. Electric strike. |
Power transfer | Standard rods (pushing function). |
Ingress protection | IP40 (42). |
Operating voltage | 230 V.a.c (+10/-15 %), 50 Hz, 10/13 A. Manufacturer guidancePower consumption of drive system max. 560 W. Rated motor capacity 100 W. Stand-by consumption 4 W. Power supply, external user 24 VDC (±10 %), 2 A. |
Speed | Opening/ closing speed: 40°/s. |
Torque | Output shaft torque permanent maximum: 80 Nm, short maximum: 240 Nm. |
Activation | Access control system. Activation sensor. Stainless Steel Push Plate - engraved "Push to Open". |
Material | Aluminium Stainless steel |