You are viewing content for United Kingdom.
Choose a country to see content for your location. Changing region will navigate you to the homepage.
Verified by manufacturer 3 days ago
2 mm thick
LUCIDEON Test Report
Certificate type
EPD
Certificate type
Reaction to Fire Classification
Certificate type
CWCT Certificate
Certificate type
EPD
Certificate type
Secret fix, 50 mm-deep cassette panel in 2 and 3 mm aluminium. Panels are installed through the hook-on mechanism to specially designed bespoke rails.
Secret fix, 50 mm-deep cassette panel in 2 and 3 mm aluminium. Panels are installed through the hook-on mechanism to specially designed bespoke rails.
Also available in interlocking or discrete-fix formats, specified separately.
Features and benefits:
Color | Beige Black Blue Bronze Brown |
Finish | Powder-coated Anodized PVdF Stainless steel Other Guidance for specification option: Corten, zinc and ACM finishes available. |
Material | Aluminium |
Shape | Square Rectangle Other |
Length | Bespoke |
Width | Bespoke |
Height | 2 mm 3 mm |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
SKU Code | DF-HC |
Classification data | |
Standards | |
Sheet roofing and cladding products | To BS EN 14782. |
Alloy | |
Grade | To BS EN 573-3:2009, Grade 1050A. Guidance for specification option: Consult manufacturer's literature for mechanical properties. |
Temper | To BS EN 515:2017, H14. |
Sheet thickness | 2 mm. |
Panel size | Guidance for specification option: Consult manufacturer for options and insert requirements, including drawing or schedule as appropriate. Manufacturer guidance50 mm deep. |
Finish | |
Material | Powder-coated. Anodized. Corten. Stainless steel. Zinc PVDF. ACM. |
Thickness | Manufacturer’s standard. Guidance for specification option: Dependent on Finish specified. |
Colour | Guidance for specification option: Consult manufacturer for options depending on required finish and insert requirements. |
Reaction to fire | |
Panel external face | To EN 13501-1:2018, A2-s1,d0. Guidance for specification option: Classification report available, consult manufacturer for details. |
Panel internal face | To EN 13501-1:2018, A2-s1,d0. Guidance for specification option: Classification report available, consult manufacturer for details. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer’s standard. |
Testing | Tested to CWCT Sequence B for air permeability, water tightness, wind resistance and impact. |
Weight | 5.4 kg/m². |
Material | Aluminium |
| Carbon dioxide equivalent | |
Carbon dioxide equivalent, as defined in BS EN 15804 Certified | |
Stage Normalised unit (kg CO₂ eq/kg) Declared unit (kg CO₂ eq/m²) Stage:A1–A3 ('Production stage') Normalised unit : Declared unit : 113 Lower emissions | |
Recyclability | Manufacturer guidanceAluminium is 100% recyclable. |
EVOX - Brochure
EVOX - Standard Capping Detail - 001
EVOX - Standard Capping Detail - 002
EVOX DF-HC - DoP
DF HC Details 023 to 033-HC 023
DF HC Details 023 to 033-HC 025
DF HC Details 023 to 033-HC 032
DF HC Details 023 to 033-HC 029
DF HC Details 023 to 033-HC 027
DF HC Details 023 to 033-HC 024
DF HC Details 023 to 033-HC 030
DF HC Details 023 to 033-HC 031
DF HC Details 023 to 033-HC 028
DF HC Details 023 to 033-HC 026
DF HC Details 023 to 033-HC 033