NBS Source
I'm a manufacturer

Electric Strike Fire Rated (FF118FRR)

Verified by manufacturer 10 months ago

Abloy UK

Fail locked monitoring electric strike.

Jump to:
+44 (0)1902 364500 Website

Application

  • For use as fire doors in commercial and public buildings such as single- or two-leaf doors in hospitals, hotels, airports or government offices.
  • Suitable for use as multi-functional and heavy duty doors in industrial buildings.

Description

Electric strike model with a monitoring contact as potential-free changeover contact, actuated using a lever on the latch bolt. The product can also be used as a heavy duty electric strike.


Features and benefits:

  • Radius keep, FaFix®, adjustable by 3 mm.
  • FaFix® latch adjustable in 0.5 mm increments.
  • Universal voltage.
  • Screw-in terminal/ plug-in connection.
  • Symmetrical design.
  • DIN left/ right as well as horizontal applicable bipolar diode.

General information

Material

Steel

Shape

Rectangular

Size

74 x 16 x 25.5 mm

Uniclass

Pr_75_30_27_26 Electric strikes and faceplatesPrimary

CAWS

P21/24 Door locks

P21/515 Door locks

P21/28 Door latches

P21/540 Door latches

Specification data - Electric strikes and faceplates

Standards

To BS EN 14846.

Rated operational voltage (Ue)

10–24 V.dc.

Operation in the event of mains failure

Fail locked.

Monitoring

Monitoring contact (RR).

Material and finish

Steel.

Colour

Self-coloured.

Operating temperature range

-15°C to 40°C.

Execution

Installing electric locks.

Product Reference

Electric Strike Fire Rated (FF118FRR)

Resistance

9000 N.

Manufacturer guidance

Break in resistance.

Height

74 mm.

Width

16 mm.

Depth

25.5 mm.

AdjustmentRange

3 mm.

Manufacturer guidance

FaFix® adjustment range.

Bolt

6 mm.

Manufacturer guidance

Latch bolt engaging depth.

Cycles

25, 0000.

Manufacturer guidance

Load cycles for in-plant test.

Position

Horizontal.

Vertical.

Manufacturer guidance

Installation position.

Electrical resistance

43,00 Ω.

Power consumption

280–560 mA.

Guidance for specification option:

Rated current consumption 12—24 V.dc.

Latch

200 N.

Guidance for specification option:

Preload AC.

Preload DC (stabilised) 50 N.

Manufacturer guidance

Latch preload.