NBS Source
I'm a manufacturer

DuPont™ AirGuard® Reflective

Verified by manufacturer 10 days ago

DuPont™ Tyvek®

Internal airtight vapour control layer (AVCL) offering high vapour resistance and low emissivity.

Jump to:
BOS
+44 (0) 117 452 9050 Website

Application

Suitable for use in SFS, timber, CLT and masonry wall systems, pitched and flat roofs. Suitable for installation behind internal linings of wall or roof assemblies or on cement particle board behind insulation in rain screen-cladding systems.

Description

A 100% airtight vapour control layer (AVCL) with very high

vapour resistance and low emissivity reflective surface.


Features and benefits:

  • Chlorine resistant.
  • Significantly boosts thermal performance when used with a services void/ batten space.
  • Highly vapour resistant.
  • Airtight and water resistant.
  • CE-conformity for plastic and rubber vapour control layer (EN 13984).
  • Reflects ca. 95% of radiant heat.
  • Reduces heat loss by increasing R-value of the airspace to 0.75 m²k/w.
  • Good mechanical strength.
  • Reaction to fire: Class E.
  • Considerably reduces risk of condensation.

General information

Color

Silver

Finish

Metallic

Material

Polypropylene

Polyethylene

Aluminium

Shape

Other

Guidance for specification option:

Roll.

Length

50000 mm

Width

1500 mm

Uniclass

Pr_25_57_65_60 Plastics sheetsPrimary

CAWS

H20/10 Sheet cladding

H20/150 Sheet cladding (attached to metal support systems)

H20/155 Sheet cladding (attached to timber battens)

H30/10 Fibre cement

H30/110 Fibre cement

H30/120 Fibre cement

H30/261 Air and vapour control membrane

H30/30 Air and vapour control membrane

H31/10 Metal

H31/110 Metal

H31/120 Metal

H31/261 Air and vapour control membrane

H31/45 Air and vapour control membrane

H40/110 GRC cladding

H40/230 Air barrier

H51/110 Cladding

K10/155 Wall lining system (metal studs)

K21/10 Wood laminate flooring

K21/110 Wood flooring

K21/115 Wood laminate flooring

K21/120 Battened wood flooring

K21/130 Battened wood floating floor

K21/140 Battened wood laminate flooring

K21/145 Composite laminate flooring

K21/146 Laminate flooring

K21/150 Wood lining

K21/160 Wood lining on battens

M30/265 Building paper

P10/240 Insulation fitted between floor joists

P10/310 Air and vapour control layer

P10/60 Air and vapour control layer

Specification data - Plastics sheets

Material

Polypropylene and polyethylene with aluminium foil.

Purpose

Vapour control layer.

Standard

To BS EN 13859-2.

Performance characteristics

-

Tensile strength (minimum)

210 N/50 mm.

Tear resistance

247 N/ 223 N.

Elongation to break

25 %/ 22 %.

Water vapour resistance (minimum)

10 000 MN·s/g.

Fire performance

To EN 13501-1, class E.

Third-party certification

British Board of Agrément (BBA) Certificate.

Form

Spun-bonded.

Root inhibitor

Aluminium foil.

Physical properties

-

Colour

Grey.

Weight (minimum)

149 g/m².

Dimensions

-

Thickness (minimum)

0.43 mm.

Width (minimum)

1.5 m.

Roll length (minimum)

50 m.

Accessories

Tyvek® 2060B Tape.

Guidance for specification option:

Single sided tape composed of an acrylic adhesive on a metallised Tyvek carrier. For sealing laps in metallised Tyvek® membranes and making good around penetrations, pipework, windows and door openings. Roll size: 75mm x 25m.

Tyvek® Double Sided Acrylic Tape.

Guidance for specification option:

Double sided acrylic tape for sealing laps in Tyvek® membrane and bonding to smooth surfaces. Excellent adhesion properties under extreme conditions. Strong initial tack. Roll size: 50mm x 25m.

Tyvek® Butyl Tape.

Guidance for specification option:

Double sided butyl based sealant, used to seal fixing penetrations in a Tyvek® membrane and form a moisture and airtight seal between a Tyvek® membrane and most commonly used building materials. Tape is compatible with brickwork, blockwork, masonry, timber, metalwork and most plastic products. Roll sizes: 20mm x 30m, 50mm x 30m.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

Europe

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

0.61 kg CO₂ eq/m²

Self declared

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC
-

2

Revit
-

2

Literature

Tyvek Technical Wall Manual 2022

Tyvek Technical Wall Manual 2022

Tyvek Technical Roof Guide 2022

Tyvek Technical Roof Guide 2022