Delta Ultra Control VCL - Vapour Control Layer

Verified by manufacturer 4 months ago

Delta Membrane Systems Ltd

Highly reflective air and vapour control layer (AVCL)

Jump to:
BOS
+44 (0)1992 523523 Website

Application

Suitable for timber, masonry or steel construction.

Description

A highly reflective air and vapour control layer (AVCL), offers low emissivity to enhance thermal performance of

walls, ceilings and floors.


Features and benefits:

  • Strong insulating properties.
  • Delivers an airtight system with sealed laps.
  • Helps avoid condensation risk in accordance with BS 5250:2011+A:2016.
  • Excellent nail tear resistance.
  • High tensile strength, tough and durable.
  • low emissivity reflective surface.
  • Enhances thermal performance of the structure when used in a still air cavity.
  • Easy to cut and lightweight to handle.
  • Available with integrated tape to seal overlaps to ensure radiant heat is reflected back into the structure, minimising absorption and energy transfer.
  • Class 1 surface spread of flame to BS 476-7: 1997 fire test on building materials and structures. Method of test to determine the classification of the surface spread of flame of products.
  • Thermal resistance: 0.78m²K/W heat flow horizontal to EN ISO 8990.
  • Emissivity of the surface (0.02³) unaged to BS EN 15976.
  • Emissivity of the surface (0.03³) aged to BS EN 15976.
  • Resistance to water penetration to BS EN 1928 with mods Class W1.

General information

Length

50000 mm

Width

1500 mm

Warranty description

Ten year

Uniclass

Pr_25_57_65_60 Plastics sheetsPrimary

CAWS

J31/30 Laying air and vapour control layer

J31/330 Air and vapour control layer

Specification data - Plastics sheets

Performance characteristics

-

Tensile strength (minimum)

N/50 mm to EN 12311-1.

Tear resistance

to EN 12310-1 with mods 160N (MD along roll) 160N (CD across roll).

Water vapour resistance (minimum)

589 MN·s/g to EN 1931.

Fire performance

Class 1 surface spread of flame to BS 476-7: 1997.

Physical properties

-

Weight (minimum)

150 g/m².

Dimensions

-

Width (minimum)

1.5 m.

Roll length (minimum)

50 m.

HeatingAirFlowRate

Horizontal.

Guidance for specification option:

>20mm Airspace - 0.78m²K/W.

Upwards.

Guidance for specification option:

>13mm Airspace - 0.53m²K/W.

Downwards.

Guidance for specification option:

50mm Airspace - 1.53m²K/W.

Sustainability data

Contains Red List materials

No

Recyclability

No

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

0 %

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1