Verified by manufacturer 17 days ago
Standard profile
BBA Agrément Certificate
Certificate type
Corium system comprising interlocking steel backing sections (rails) which are profiled to allow fired clay brick tiles to be clipped in, providing a mechanical fix.
Suitable for use as a protective/decorative cladding over SFS, concrete, timber frame and masonry substrate walls. Can also be used with insulated panel systems and for off-site fabrication. Corium can be installed horizontally or vertically and used overhead to create brick soffits and ceilings.
The Corium system comprises interlocking steel backing sections (rails) which are profiled to allow fired clay brick tiles to be clipped in, providing a mechanical fix. The vertical and horizontal joints between the tiles are pointed with mortar to provide a brickwork finish.
Features and benefits:
Components:
Color | Orange Guidance for specification option: Terracotta. Red Black White Cream |
Finish | Glazed Matt Smooth Sanded Dragfaced |
Material | Clay Steel Stainless steel Brick |
Shape | Rectangle |
Length | 327 mm 215 mm 102.5 mm Bespoke Manufacturer guidanceCorium brick tiles can be extruded in bespoke lengths up to a maximum of 327 mm. |
Width | 32 mm 47 mm 52 mm 82 mm Bespoke Manufacturer guidanceStandard brick tiles have a thickness of 32 mm. |
Height | 215 mm 140 mm 65 mm 50 mm Bespoke |
Warranty description | 25 year Guidance for specification option: Material Warranty up to 25 years. |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
Breather membrane | |
Fasteners | Manufacturer guidanceAustenitic stainless steel fasteners with integral sealing washer (EPDM or similar) under the head should be specified to suit the support material to which Corium is being fixed. Fasteners should be minimum of 5.5 x 25 mm (diameter x length) with an 8 mm hexagonal head. The installer should seek approval of the fastener selection from the project engineer. |
Secondary support structure | Interlocking steel backing sections.Manufacturer guidanceThe system transfers its self-weight and design wind loads through the supporting sub-frame to the substrate wall. The substrate wall and supporting subframe must be capable of resisting the associated loads. |
Cavity fire barriers | |
Horizontal | Manufacturer guidanceBoth horizontal and vertical cavity fire barriers should be installed in the rainscreen cavity zone to comply with building and statutory regulations. The cavity fire barriers must be designed and tested for use in a rainscreen system and be fully passive and non-combustible. The number and location of the cavity fire barriers is determined by the respective design teams and their fire consultants on an individual project basis. |
Cladding panels | |
Material | Facing brick. |
Dry weight | 0.83 kg. Guidance for specification option: Standard tile. |
Work sizes | 215 x 32 x 65 mm. 215 x 32 x 50 mm. 215 x 32 x 140 mm. 327 x 32 x 215 mm. 215 x 52 x 65 mm. |
Finished size | 215 x 32 x 65 mm. 215 x 32 x 50 mm. 215 x 32 x 140 mm. 327 x 32 x 215 mm. 215 x 52 x 65 mm. |
Third-party certification | BBA certified. |
Surface texture | Glazed. Matt. Smooth. Dragfaced. Creased. |
Colour | Orange. Guidance for specification option: Terracotta. Red. Black. White. Cream. |
Contains Red List materials | No |
Country of material origin | Germany Guidance for specification option: Country of Origin - Germany (brick tiles), Denmark, United Kingdom. |
Country of product manufacture | Germany Guidance for specification option: Brick tiles - Germany. |
Material | Clay Steel Stainless steel Brick |
Recyclability | 100% Guidance for specification option: Steel backing rails are 100% recyclable. |