Verified by manufacturer 2 months ago
CME2.1 Q Plus
Range of fans providing continuous extract of stale, damp and polluted air to the outside environment.
Primarily for use in dwellings with six wet rooms, such as kitchens or bathrooms, or fewer.
Suitable for hidden ceiling installation in flats and apartments.
Range of fans providing continuous extract of stale, damp and polluted air to the outside environment.
An MEV or CME (Continuous Mechanical Extract Ventilation) system uses background ventilators, usually trickle ventilators fitted in windows and a centrally located continuously running mechanical extract fan with ducts running from the moisture producing areas or “wet rooms” such as kitchens and bathrooms.
The background ventilators provide the whole building ventilation and the central mechanical extract fan runs continuously to remove odours and excessive humidity. A boost facility provides rapid extraction when necessary to remove higher levels of pollutants.
Features and benefits:
CME2/ 2.1 specific:
CME 3/ 3.1 specific:
Airflow at 100 Pa:
Color | Grey Guidance for specification option: Light and dark grey. |
Finish | Smooth |
Material | Polypropylene Guidance for specification option: Housing (talc filled). |
Shape | Rectangle |
Length | 340 mm 421 mm |
Width | 310 mm 355 mm |
Height | 252 mm |
Warranty description | Three year Guidance for specification option: UK only; consult manufacturer for details. |
Uniclass | |
CAWS | U90/413 Ventilation fan units U90/413 Ventilation fan units |
Standards | |
Performance testing | Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398. |
Safety | To EN 60335-1:2002/A2:2006 and EN 60335-2-80:2003/A1:2004. |
Third-party certification | CE marked. |
Duty | 103 L/s (371 m³/h) at 200 Pa. |
Mounting | Ceiling.Other.Guidance for specification option: Insert requirements; can be mounted on any plane. |
Controls | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. Adjustable humidity sensor.Manufacturer guidanceFan speed setting is 100% variable. |
Dimensions | 421 x 355 x 252 mm. Guidance for specification option: Length x width x height (when installed on a ceiling). Service void requirements: 590 x 550 x 450 mm. Manufacturer guidanceExcluding spigots. |
Weight | 5 kg. |
Materials | Housing: talc-filled polypropylene. |
Electrical | 230 V, 50/ 60 Hz, 3 A fuse. |
Performance | Maximum number of kitchen and/ or wet rooms: Six. Guidance for specification option: Specific fan power (SFP) varies with external terminal configuration; consult manufacturer's literature for details. |
Colour/ Finish | Light grey/ dark grey. |
Model | CME2.1 Q Plus. |
Material | Polypropylene Guidance for specification option: Housing (talc filled). |
Platform | Compatible | Version |
---|---|---|
- | 1 |