You are viewing content for United Kingdom.
Choose a country to see content for your location. Changing region will navigate you to the homepage.
Verified by manufacturer 27 days ago
40 mm thick
Extruded polystyrene foam (XPS) insulation available 40–400 mm thick and suitable for flat/ inverted roofs.
For flat/ inverted roofs.
BEWI Jackodur® EVO 300 Inverted Roof is the new generation of XPS using CO2 and multilayer manufacturing technologies delivering insulation characteristics with a declared (λD) 0.032 W/m·K.
BEWI Jackodur® EVO 300 Inverted Roof Insulation is manufactured in accordance with BS EN 13164 under a Quality Assurance System approved to ISO 9001 and Environmental Management System to ISO 14001.
Features and benefits:
Color | Purple |
Finish | Smooth |
Material | Extruded polystyrene (XPS) |
Shape | Rectangle |
Length | 1250 mm |
Width | 600 mm |
Height | 40 mm 50 mm 60 mm 80 mm 100 mm Manufacturer guidanceThickness. |
Uniclass | |
CAWS | M10/40 Floating construction M13/40 Floating construction J41/26 Thermal insulation J21/410 Expanded polystyrene insulation J21/25 Warm deck roof insulation Q37/110 Intensive green roofs J31/331 Expanded polystyrene (EPS) insulation M21/210 Rendered external wall insulation systems J41/410 Expanded polystyrene (EPS) insulation E20/30 Underslab insulation J42/27 Thermal insulation Q37/310 Inverted roof insulation J42/410 Expanded polystyrene (EPS) insulation M13/260 Floating construction M10/290 Floating construction J31/26 Thermal insulation E20/200 Proprietary underslab insulation M21/20 External wall insulation systems |
Classification data | |
Standard | To BS EN 13164. |
Third-party certification | BBA Certified 21/5944 Product Sheet 4 (Pending). |
Fire performance | To EN 13501-1, Euroclass E. |
Compressive strength (minimum) at 10% compression | 300 kPa. |
Thermal conductivity (maximum) | Declared: 0.034 W/m·K. |
Water permeability | Total immersion: ≤0.7%; Diffusion: Class WD(V) ≤3. |
Water vapour permeability | 160 μ. |
Thickness | 40 mm. |
Face size (length x width) | 1250 x 600 mm. Guidance for specification option: Coverage: 0.75 m². |
Edges | Shiplap. |
U-value | 0.73 W/m²K. |
Thermal resistance | 1.15 m²K/W. |
Material | Extruded polystyrene (XPS) |