2018 Model
An air-cooled multifunctional unit equipped with axial fans and scroll compressors for outdoor installation.
Air-cooled reversible heat pumps designed for medium-temperature heating, cooling, and domestic hot water, offering efficiency and flexibility for diverse applications.
Baxi (BHP2-P/G 2018–2060) is an air-cooled multifunctional unit equipped with axial fans and scroll compressors for outdoor installation, intended for use in four-pipe systems. It has two sections: one for producing chilled water (evaporator side) and the other for producing hot water (condenser side).
Features and benefits:
Color | White |
Finish | Powder-coated |
Material | Steel |
Shape | Rectangle |
Length | 2350 mm 3550 mm 4700 mm |
Width | 1100 mm |
Height | 1950 mm 2250 mm |
Warranty description | Five year Manufacturer guidanceWarranty is 12 Months from startup or 18 months from delivery, whichever is sooner. Extended warranty up to 5 years |
Uniclass | |
CAWS | T90/505 Air-to-water heat pumps |
SKU Code | BHP2-P/G 2018-2060 |
Classification data | |
Standards | |
Test requirements | To EN 15411. |
Heat pump type | Monobloc. |
Mode | Heating and cooling. |
Coefficient of performance (minimum) | 3.26. Guidance for specification option: To BS EN 14511. |
Energy efficiency | 164% (cooling); 137% (heating). |
Integrated service fittings | Domestic hot water circulating pump, heating circulating pump, and heating expansion vessel. |
Output | |
Heating | 52.2 kW. |
Cooling | 48.6 kW. |
Fan | |
Type | Axial. EC fan. EC high static fan. |
Fan drive | Direct. |
Configuration | Vertical. |
Electrical supply type | Three-phase. |
Compressor | |
Type | Scroll. |
Sealing | Manufacturer's standard. |
Drive | Manufacturer's standard. |
Sound power level | 72 dB(A). Manufacturer guidanceCompliant with DIN 45635. |
Accessories | Not required. EC inverter fans. Guidance for specification option: Optional extra. IM - Automatic circuit breakers. Guidance for specification option: Alternative to fuses and thermal relays. PFC1 - Power factor correction condensers. Guidance for specification option: Cosφ 0.95. SL - Unit silencement. Guidance for specification option: The compressors are equipped with sound-absorbing covering. RFM - Cooling circuit shut-off valve on discharge line. RFL - Cooling circuit shut-off valve on liquid line. BT - Low water temperature kit. Guidance for specification option: Required in case of unit’s operation with the evaporator’s outlet water temperature below 5°C. EC - EC Inverter fans. Guidance for specification option: Axial fans directly coupled to a three-phase electric motor with external rotor. A safety fan guard is fitted on the air flow discharge. ECH - EC Inverter fans with high ESP. Guidance for specification option: Axial fans directly coupled to an Inverter three-phase electric motor and fitted with an enhanced nozzle to increase both efficiency and available static pressure, with a range from 60 to 110 Pa. Their use allows ducted/indoor installation. A safety fan guard is fitted on the air flow discharge. TX - Coil with pre-coated fins. PSC - Single circulating pump cooling side. Guidance for specification option: Installed inside the unit. PSIC - Inverter single circulating pump cooling side. Guidance for specification option: Installed inside the unit. PDC - Double circulating pump cooling side. Guidance for specification option: Installed inside the unit, one pump in operation and the other in stand-by mode. At every start request, the pump with less operating hours is activated first. PDIC - Inverter double circulating pump cooling side. Guidance for specification option: Installed inside the unit. PSH - Single circulating pump heating side. Guidance for specification option: Installed inside the unit. PSIH - Inverter single circulating pump heating side. Guidance for specification option: Installed inside the unit. PDH - Double circulating pump heating side. Guidance for specification option: Installed inside the unit. PDIH - Inverter double circulating pump heating side. Guidance for specification option: Installed inside the unit. PSC+PSH - Single circulating pump cooling side + heating side. PSIC+PSIH - Inverter single circulating pump cooling side + heating side. PDC+PDH - Double circulating pump cooling side + heating side. PDIC+PDIH - Inverter double circulating pump cooling side + heating side. GS - Single circulating pump gasket for glycol >30%. GD - Double circulating pump gaskets for glycol >30%. GH - Single circulating pump cooling side + heating side gaskets for glycol >30%. GY - Double circulating pump cooling side + heating side gaskets for glycol >30%. FNC - Antifreeze heater for pipes cooling side. FGC - Antifreeze heater for single pump and pipes cooling side. FMC - Antifreeze heater for double pump and pipes cooling side. FNH - Antifreeze heater for pipes heating side. FGH - Antifreeze heater for single pump and pipes heating side. FMH - Antifreeze heater for double pump and pipes heating side. SS - Soft start. TS - Touch Screen interface. WM - Web Monitoring. Guidance for specification option: It enables monitoring and remote management of the system. IS - Modbus RTU protocol, RS485 serial interface. IST - Modbus TCP/IP protocol, ethernet port. Guidance for specification option: Web Server included. ISB - BACnet MSTP protocol, RS485 serial interface. Guidance for specification option: Web Server included. ISBT - BACnet TCP/IP protocol, Ethernet port. Guidance for specification option: Web Server included. ISS - SNMP protocol, Ethernet port. Guidance for specification option: Web Server included. IAA - Remote set-point, 4–20 mA signal. Guidance for specification option: It allows variation of the unit operating set-point through an analogue signal. IAS - Remote signal for second set-point activation. Guidance for specification option: It allows remote activation of the second set-point. IAV - Remote set-point, 0–10 V signal. Guidance for specification option: It allows variation of the unit operating set-point through a digital signal. IDL - Demand limit from digital input. Guidance for specification option: It allows limiting the unit absorbed power. CP - Potential free contacts. Guidance for specification option: For remote alarm and control. GDS - Leak detector. MN - High- and low-pressure gauges. Guidance for specification option: One for each refrigerant circuit. |
Refrigerant | R454B. R452B. |
Dimensions | 2350 x 1100 x 1950 mm. |
Weight | 220 kg (transport weight 814 kg). |
Country of product manufacture | Italy |
Manufacturing plant location | |
Material | Steel |