NBS Source
I'm a manufacturer

Bauder Total Green Roof System Reinforced Bitumen Membrane Warm Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Verified by manufacturer 1 year ago

Bauder Ltd Third party certifications:
  • EPD

    EPD

    Certificate type

  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • CCPI System

    CCPI System

    Certificate type

Incorporating torch-on bitumen root resistant capping sheet with self-adhered bitumen underlayer, insulation and self-adhered bitumen air and vapour control layer (AVCL).

Jump to:
BOS
+44 (0)1473 257671 Website

Application

Suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios.

Description

Total bitumen green warm roof system, incorporating torch-on bitumen root resistant capping sheet with self-adhered bitumen underlayer, insulation and self-adhered bitumen air and vapour control layer (AVCL).

Bauder Total Green Roof System (BTGRS) is suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios.

See BBA certification 10/4744. BTGRS can meet current UK Building Regulations Part B for external fire protection.


Features and benefits:

  • Capping sheet with tensile strength up to 1000 N/50mm.
  • Withstands climatic extremes of over 100⁰C variation.
  • Patented self-adhesive DUO products. The "DUO" lap technology ensures thorough sealing of lap joints, even in lower temperatures.
  • Expandable graphite fire retardant reduces spread of flame.
  • Heavy duty, robust and extremely tough.
  • Service life in excess of 35 years as stated in BBA certificate 10/4744.
  • Resistant to European climatic conditions.
  • Membrane resists impact and tearing.
  • Can satisfy requirements of Part B of Building Regulations.

General information

Color

Black

Material

Bitumen

Shape

Square

Rectangle

Uniclass

Ss_30_40_30_72 Reinforced bitumen membrane warm roof covering systemsPrimary

CAWS

J41/10 Reinforced bitumen membrane warm deck roof covering

J41/110 Built-up reinforced bitumen membrane warm deck roof covering

Product range

Built-Up Bituminous Systems

Specification data - Reinforced bitumen membrane warm roof covering systems

Preparation

-

Horizontal work

Activator-Primer (Canister) APR01 – Black.

Guidance for specification option:

Synthetic rubber resin-based primer, developed to provide the necessary preparation of substrates prior to the installation of self-adhesive and torch-applied membranes. The spray application offers improved film thickness speed of application (by up to 50% over roller applied products) and quick drying in a matter of minutes.

  • Coverage: Approx. 96 g/m² (300 mm wide spray one coat, 192 g/m² two coats). Two coats may be required for very porous substrates.
  • Application temperature: +5 to +30°C.
  • Drying time (at 10°C): 5–10 minutes.
  • Colour: Black.
  • Recoat time if left exposed: Four hours.
  • Suitable substrates: Oriented strand board (OSB); plywood; timber; concrete; lightweight concrete or cementitious materials; metal; Bauder self-adhesive underlayers; existing asphalt and bitumen membranes; polyisocyanurate (PIR) insulation.
  • Non-suitable substrates: Mica finished surfaces (e.g. KSD FBS); Laminated paper-foil faced insulation; expanded polystyrene (EPS) or extruded polystyrene (XPS) insulations; BauderROCK or mineral wool insulation; BauderGLAS or cellular glass insulation; copper; thermoplastic waterproofing membranes.

Manufacturer guidance

Contact Bauder to confirm substrate suitability if required.

Skirtings and vertical work

As 'Horizontal work'.

Air and vapour control layer

-

Type

KSD FBS.

Guidance for specification option:

Robust, self-adhesive elastomeric bitumen air and vapour control layer (AVCL), with a mica finished upper surface to allow easy bonding of insulation using appropriate Bauder Insulation Adhesive. One side lap features an 80 mm wide glass fleece along the underside, and a 100 mm strip of aluminium foil above. The other side lap has a thermofusible film on the top surface. This arrangement ensures that laps are heat sealed using hot air or gas torch as appropriate to extrude a bitumen bead, thus ensuring waterproofing integrity.

  • Width: 1.08 m.
  • Length: 10 m.
  • Thickness: 2.5 mm.
  • Weight: 2.5 kg/m².
  • Reinforcement: Polyester coated aluminium foil and 200 g/m² glass fleece.
  • Tensile strength: Length and Diagonal ≥ 1000 N/50mm.
  • Cold bending test: -25°C.
  • Elongation at break: Length and Diagonal ≥ 2%.

Therm DS 1 DUO.

Guidance for specification option:

Self-adhesive elastomeric bitumen air and vapour control layer with patented “DUO” lap technology to ensure thorough sealing of lap joints, even in lower temperatures. The product also features thermally activated bitumen stripes on its top surface to provide the bonding compound for the insulation boards. Allows for cleaner, safer and faster installation than traditional torch applied membranes.

  • Width: 1.08 m.
  • Length: 7.5 m.
  • Thickness: 3.5 mm.
  • Weight: 4.5 kg/m².
  • Reinforcement: Polyester coated aluminium foil and 60 g/m² glass fleece.
  • Tensile strength: Length ≥400 N/50mm and Diagonal ≥ 300 N/50mm.
  • Cold bending test: -25°C.
  • Elongation at break: Length and Diagonal ≥ 2%.

Attachment

Self-adhesive.

Insulation

-

Type

BauderGLAS Flatboard.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – Twin cartridge.

Cellular glass insulation suitable for projects that require a high level of compressive strength and/ or to be non-combustible.

  • Type: Cellular glass flatboard insulation board.
  • Facing: Glass tissue or none faced (depending upon system).
  • Density: 100 kg/m³.
  • Board size: Contact manufacturer for options.
  • Thickness (Flatboard): 50 mm, 60 mm, 70 mm, 80 mm, 90 mm, 100 mm, 110 mm, 120 mm, 130 mm, 140 mm, 150 mm, 170 mm, 180 mm (also available in Tapered).
  • Thermal conductivity: 0.036 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: 0.5 N/mm².

BauderGLAS Tapered.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – Twin cartridge.

Cellular glass insulation suitable for projects that require a high level of compressive strength and/ or to be non-combustible.

  • Type: Cellular glass tapered insulation board.
  • Facing: Glass tissue or none faced (depending upon system).
  • Density: 100 kg/m³.
  • Board size: Contact manufacturer for options.
  • Thickness (Flatboard): 50 mm, 60 mm, 70 mm, 80 mm, 90 mm, 100 mm, 110 mm, 120 mm, 130 mm, 140 mm, 150 mm, 170 mm, 180 mm.
  • Thermal conductivity: 0.036 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: 0.5 N/mm².

BauderROCK Flatboard.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – Twin cartridge or mechanically fixed.

Mineral fibre insulation suitable for projects that require a high level of sound reduction and/ or to be non-combustible, and has a zero GWP and ODP rating.

  • Type: Dual density mineral wool flatboard insulation board.
  • Facing: Top: 300 g/m² glass fibre fleece; Bottom: Unfaced.
  • Density: 160 kg/m³.
  • Board size: 1200 x 1000 mm.
  • Board thickness (Flatboard): 60 mm, 85 mm, 105 mm, 115 mm, 150 mm, 170 mm, 185 mm (also available in Tapered).
  • Thermal conductivity: 0.039 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: >0.12 N/mm² (minimum 0.08 N/mm²).

BauderROCK Tapered.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – Twin cartridge or mechanically fixed.

Mineral fibre insulation suitable for projects that require a high level of sound reduction and/ or to be non-combustible, and has a zero GWP and ODP rating.

  • Type: Dual density mineral wool tapered insulation board.
  • Facing: Top: 300 g/m² glass fibre fleece; Bottom: Unfaced.
  • Density: 160 kg/m³.
  • Board size: 1200 x 1000 mm.
  • Board thickness (Flatboard): 60 mm, 85 mm, 105 mm, 115 mm, 150 mm, 170 mm, 185 mm.
  • Thermal conductivity: 0.039 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: >0.12 N/mm² (minimum 0.08 N/mm²).

BauderVIP TE 60 mm Flatboard.

Guidance for specification option:

  • Type: Vacuum insulation panel with pyrogenic silica vacuum core, 40 mm.
  • Facing: Top: High density PIR, 17 mm; Bottom: Rubber granulate, 3 mm.
  • Density: 13 kg/m².
  • Standard board sizes: 1000 x 1000 mm and 1000 x 500 mm.
  • Standard board thickness: 60 mm.
  • Thermal conductivity: 0.009 W/m·K.
  • Compressive strength: >0.12 N/mm².

BaduerVIP TE 80 mm Flatboard.

Guidance for specification option:

  • Type: Vacuum insulation panel with pyrogenic silica vacuum core, 60 mm.
  • Facing: Top: High density PIR, 17 mm; Bottom: Rubber granulate, 3 mm.
  • Density: 17 kg/m².
  • Board sizes: 1000 x 1000 mm, 1000 x 500 mm.
  • Board thickness: 80 mm.
  • Thermal Conductivity: 0.009 W/m·K.
  • Compressive strength: >0.12 N/mm².

PIR FA G16 foil-faced tapered insulation.

Guidance for specification option:

Insert required thickness.


  • Type: Rigid closed-cell polyisocyanurate (PIR) roofboard: To BS EN 13165.
  • Facing: Black aluminium foil to both faces.
  • Density: >30 kg/m³.
  • Standard board size: 1200 x 1200 mm.
  • Board thickness: Contact manufacturer for options.
  • Thermal conductivity: 0.022 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: >0.12 N/mm².
  • PIR index: >250 (extremely high dimensional stability).

PIR FA-TE Flatboard.

Guidance for specification option:

Insert required thickness.


  • Type: Rigid closed-cell polyisocyanurate (PIR) roofboard: To BS EN 13165.
  • Facing: Aluminium foil to both faces.
  • Density: >30 kg/m³.
  • Standard board size: 1200 x 600 mm.
  • Board thickness: 30 mm, 40 mm, 50 mm, 60 mm, 80 mm, 100 mm, 120 mm, 140 mm, 160 mm.
  • Thermal conductivity: 0.022 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: >0.12 N/mm².
  • PIR index: >250 (extremely high dimensional stability).

Fixing

Activator-Primer (Canister) APR01 – Black.

PU Insulation Adhesive – Tin.

Guidance for specification option:

Not for foil to foil applications (e.g. FA-TE to FA-TE).

PU Insulation Adhesive – Twin cartridge.

Waterproof covering

-

First layer

-

Type

BauderTEC KSA DUO.

Guidance for specification option:

A technically advanced self-adhesive SBS elastomeric bitumen underlayer with “DUO” lap technology to ensure thorough sealing of lap joints, even in lower temperatures. The product features a glass lattice reinforcement for strength and stability. The product benefits from cleaner, safer and faster installation than traditional torch-applied membranes.

  • Width: 1 m.
  • Length: 7.5 m.
  • Thickness: 3 mm.
  • Weight: 3.5 kg/m².
  • Surface: Top: Foil; Bottom: Peel off release film covering self-adhesive bitumen.
  • Reinforcement: 200 g/m² glass lattice.
  • Cold bending test: Top -25°C; Bottom -30°C.
  • Softening point: >100°C.
  • Tensile strength: Length >1000 N/50mm; transverse >1000 N/50mm.
  • Elongation at break: Length >2%; transverse >2%.

Attachment

Self-adhered.

Top layer

-

Type

PLANT E.

Guidance for specification option:

A high quality, heavy duty, torch-applied, elastomeric bitumen capping sheet. The product features chemically treated bitumen to deliver superior root resistance which has been tested and approved by the FLL. The membrane is reinforced with 250 g/m² spunbond polyester fleece to allow the finished product to cope with structural movement without fracture. Expandable graphite fire retardant is also incorporated to reduce spread of flame.

  • Width: 1 m.
  • Length: 5 m.
  • Thickness: 5.2 mm.
  • Weight: 6 kg/m².
  • Surface: Top: Green slate mineral chippings; Bottom: Thermofusible polyethylene.
  • Reinforcement: 250 g/m² recycled spunbond polyester.
  • Cold bending test: -36°C.
  • Softening point: >120°C.
  • Tensile strength: Length >1000 N/50 mm; transverse >1000 N/50mm.
  • Elongation at break: Length >45%; transverse >45%.

Attachment

Torch applied.

Detail work

-

Flashings

Not required.

Bauder GRP Trim.

Guidance for specification option:

GRP roof edge Trim for use with Bauder bituminous roof systems. Available colours of either grey or black and a choice of profiles to suit the requirements of most projects.

Bauder Aluminium Termination Bar.

Guidance for specification option:

Natural finish aluminium alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Bauder GRP Termination Bar.

Guidance for specification option:

Black glass reinforced plastic (GRP) alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Skirtings and upstands

Not required.

Bauder LiquiFIBRE Detailing Kit.

Guidance for specification option:

Fast curing waterproofing resin containing fibre reinforcement that can be used for detailing awkward shapes or inaccessible areas where using LiquiDETAIL is impractical. PMMA-based resin that requires a catalyst and is solvent, isocyanate and halogen free.

Bauder LiquiDETAIL.

Guidance for specification option:

Cold liquid applied fast curing waterproofing resin that can be used on upstands and details. PMMA-based resin that requires the addition of catalyst to trigger curing and is solvent, isocyanate and halogen free.

Welted drips

Required.

Guidance for specification option:

Insert requirements.

Not required.

Cover strips

Required.

Guidance for specification option:

Insert requirements.

Not required.

Ancillary items

Required.

Guidance for specification option:

Insert requirements.

Not required.

Surface protection

Not required.

Landscaping options.

Guidance for specification option:

Consult manufacturer for information.

System accessories

Not required.

Bauder lightning conductors.

Guidance for specification option:

Lightning conductor clips are a specially designed secure clip that allows for movement.

  • Bauder Lightning conductor - Type 4: Polyvinyl chloride (PVC) coated or bare conductor.

Bauder insulated rainwater outlets.

Guidance for specification option:

For maintaining thermal continuity at drainage points. Suitable for warm, cold and inverted roof construction, the high thermal value of the rigid foam body prevents condensation from forming on the underside of the outlet.

Designed for use when connecting to conventional drainage systems, with excellent flow rate performance and is suitable for both new build and refurbishment projects. Outlets are included in the Bauder waterproofing system guarantee as they are integrated components.

Flow rate figures (where applicable) are based on BS EN 12056:3:2000, typically taken using a 35 mm header of water including leaf grille:

  • Bauder Bitumen Compact Vertical Outlet DN100: Insulated internal outlet, 6.1 L/s.
  • Bauder Bitumen Vertical Outlet DN70: Insulated internal outlet, 7.1 L/s.
  • Bauder Bitumen Vertical Outlet DN150: Insulated internal outlet, 7.2 L/s.
  • Bauder Bitumen Warm Roof Refurb Outlet DN63: Insulated internal outlet, 6.1 L/s.
  • Bauder Bitumen Warm Roof Refurb Outlet DN90: Insulated internal outlet, 5.7 L/s.
  • Bauder Bitumen Refurb Outlet DN95 – Un-insulated straight drop outlet, designed to ensure the maximum flow rate of the existing downpipe is not exceeded.
  • Bauder Bitumen Refurb Outlet DN125 – Un-insulated straight drop outlet, designed to ensure the maximum flow rate of the existing downpipe is not exceeded.
  • Bauder Insulated Parapet Outlet DN100 including pre-assembled pipe and dome grate: 0.6 L/s connected to external pipework; 0.7 L/s connected to external hopper.
  • Bauder Bitumen Blue Roof Vertical Outlet DN70: Insulated internal outlet. To be used in conjunction with Bauder Bitumen Blue Roof Flow Restrictor only. Bauder Bitumen Blue Roof Vertical Outlet DN70 (when used with BauderBLUE ST-B Adjustable Blue Roof Flow Restrictor – Bitumen) flow rates are project specific and obtained via Bauder Technical.
  • BauderBLUE ST-B Adjustable Blue Roof Flow Restrictor – Bitumen. The BauderBLUE ST-B Adjustable Blue Roof Flow Restrictor – Bitumen is designed to be used in conjunction with a standard Bauder Bitumen Blue Roof Vertical Outlet DN70. The Bauder Blue Roof Bitumen Flow Restrictor is comprised of four parts; Baseplate, overflow pipe, Baseplate inner and Baseplate outer seal. The polyamide Baseplate fits within the 70 mm vertical outlet, with the EPDM outer seal creating a watertight fit. The PE-HD Overflow slots into the central hole of the Baseplate with an inner EPDM seal preventing any leaks. BauderBLUE ST-B Adjustable Blue Roof Flow Restrictor – Bitumen must be set to the requirement of the particular roof. Bauder must be consulted to carry out this bespoke design.
  • Bauder Parapet Emergency Overflow Stainless Steel DN70: Emergency overflow/ tell-tale.

Bauder rooflights/ glazing/ ventilation.

Guidance for specification option:

All these glazing products are fully compatible with the roof waterproofing systems. Consult manufacturer for details and insert requirements.

  • BauderDOME Rooflight.
  • Bauder Euroglaze Rooflight.
  • Bauder Special Modular Rooflight.
  • Bauder Continuous Rooflight.
  • Bauder Walk-on Rooflight.
  • Bauder Direct Glazing.
  • Bauder AOV.
  • Bauder Modular Link Glazing.
  • Bauder Structural Rooflight.
  • Bauder Fire Rated Rooflight.

Sustainability data

Third party certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

2

IFC
-

1

Third party certifications

EPD

EPD

Environmental Product Declaration - RBM

BBA Agrément Certificate

BBA Agrément Certificate

Certificate: Bauder Total Green Roof Systems 10/4744

CCPI System

CCPI System

Bauder BTRS-BTGRS CCPI System Certificate