Balcony Seal Brochure

Balcony Seal Brochure

Pure Vista Ltd

Pure Vistas Discrete Balustrade Drainage Blocks are simply installed under the channel and stop water getting in the building below.
Ballistic Report Mega-Grip

Ballistic Report Mega-Grip

Pure Vista Ltd

The trial objective was to carry out ballistic testing and certify the MegaGrip 1.5kN Glass Balustrade in accordance with EN1522(2) (Windows, doors, shutters and blinds) and EN1523(3) bullet resistance test protocol. Details of the Glass Balustrade are specified in Pure Vista drawing contained in Annex A.
Blast Guard test data (Anti-Terror Frameless Glass Balustrade)

Blast Guard test data (Anti-Terror Frameless Glass Balustrade)

Pure Vista Ltd

Purevista anti-terrorism and bomb resistance test report
Bullet Guard Bullet Resistant Frameless Glass Balustrade

Bullet Guard Bullet Resistant Frameless Glass Balustrade

Pure Vista Ltd

Mega-Grip 25.5mm PVB Laminate Glass Test Report

Mega-Grip 25.5mm PVB Laminate Glass Test Report

Pure Vista Ltd

Mega-Grip 3kn Frameless Glass Balustrade Channel Drawing inc dimensions

Mega-Grip 3kn Frameless Glass Balustrade Channel Drawing inc dimensions

Pure Vista Ltd

Mega-Grip Commercial Balustrade 3kn Drawing
Mega-Grip 3kn Frameless Glass Balustrade Drilling Diagram

Mega-Grip 3kn Frameless Glass Balustrade Drilling Diagram

Pure Vista Ltd

Mega-Grip Drilling Diagram
Mega-Grip 3Kn Frameless Glass Balustrade Steel Test Report

Mega-Grip 3Kn Frameless Glass Balustrade Steel Test Report

Pure Vista Ltd

Mega-Grip 3Kn Adjustable Commercial Balustrade System
Mega-Grip Farmeless Glass Balustrade 3KN Concrete Test Report

Mega-Grip Farmeless Glass Balustrade 3KN Concrete Test Report

Pure Vista Ltd

Mega-Grip Commercial Glass Balustrade direst to concrete test report for 3kn Applications
Mega-grip frameless glass balustrade Wind Load Report 1800mm high

Mega-grip frameless glass balustrade Wind Load Report 1800mm high

Pure Vista Ltd

An air bag was positioned on the face of the test panel and a reaction board was placed over this butting up-to and braced backed to the steel frame. Two linear displacement transducers were located on an independent scaffold frame reading onto the rear of the panel with one positioned at the mid-point of the panel and the second positioned at the mid-point of the top edge of the glass panel.
Mega-Grip Frameless Glass Partition Screen 1.5kn/mtr Test Report

Mega-Grip Frameless Glass Partition Screen 1.5kn/mtr Test Report

Pure Vista Ltd

A horizontal imposed line load was applied to the glass at a height of 1.8 m above the datum level of the floor and the deflection measured at the top central point of the panel 1.8 m above the datum level of the floor.
MEGAGrip 3KN Frameless Glass Balustrade Brochure

MEGAGrip 3KN Frameless Glass Balustrade Brochure

Pure Vista Ltd

MEGAGrip 3KN Adjustable Commercial Balustrade Brochure
Posi-Glaze Frameless Glass Balustrade 0.74kn 400mm Centre Test Report

Posi-Glaze Frameless Glass Balustrade 0.74kn 400mm Centre Test Report

Pure Vista Ltd

Posi-Glaze Frameless Glass Balustrade Test Report For 400mm Fixing Centres for 0.74kn/mtr loads 12mm,13.5mm Sentry 15mm and 17.5mm glass thicknesses
Posi-Glaze Frameless Glass Balustrade 21.5mm PVB Laminate Wind load report

Posi-Glaze Frameless Glass Balustrade 21.5mm PVB Laminate Wind load report

Pure Vista Ltd

Under wind loading there is no pass or fail criteria, the system will either be adequate or inadequate in any particular situation. So for example a system installed on a building at the top of an escarpment in the North of Scotland will be expected to resist much greater wind forces than one in the centre of London. However, as an indication, the speed of a 3 second gust of wind in the North of Scotland could reach 56 m/s at 10 m above the ground with a likely incidence of return of once in 50 years.
Posi-Glaze Frameless Glass Balustrade Brochure

Posi-Glaze Frameless Glass Balustrade Brochure

Pure Vista Ltd

Posi-Glaze Frameless Glass Balustrade, fully adjustable and removable glass railing system after installation.
Posi-Glaze Frameless Glass Balustrade Channel Drilling Diagram

Posi-Glaze Frameless Glass Balustrade Channel Drilling Diagram

Pure Vista Ltd

Purevista Drilling Diagram
Posi-Glaze Frameless glass balustrade side mount 1.5kn/mtr Test report

Posi-Glaze Frameless glass balustrade side mount 1.5kn/mtr Test report

Pure Vista Ltd

Lucideon Limited were commissioned by the client, Pure Vista Ltd, to carry out line load testing in accordance with BS 6180:2011 Barriers in and about buildings, to allow their balustrade system to be classified for use in accordance with the Code of Practice included within the standard
Posi-glaze Frameless Glass Balustrade Test Report (original)

Posi-glaze Frameless Glass Balustrade Test Report (original)

Pure Vista Ltd

Posi-glaze Frameless Balustrade Product (Line Load Test).
R-LOCK brochure

R-LOCK brochure

Pure Vista Ltd

R-LOCK product brochure from Pure Vista lTD
R-LOCK Deglazing Guide

R-LOCK Deglazing Guide

Pure Vista Ltd

A simple set of instructions explaining the deglazing method for R-LOCK
R-LOCKedge74 Installation Guide

R-LOCKedge74 Installation Guide

Pure Vista Ltd

Detailed instructions on the installation of R-LOCK
R-LOCKedge74 Test Report Concrete

R-LOCKedge74 Test Report Concrete

Pure Vista Ltd

R-LOCKedge74 Test Report Steel

R-LOCKedge74 Test Report Steel

Pure Vista Ltd

Spig-Lite Pro Glass Balustrade Brochure PDF

Spig-Lite Pro Glass Balustrade Brochure PDF

Pure Vista Ltd

Spig-Lite Pro Brochure
Spig-Lite Pro Glass Balustrade Drawings PDF

Spig-Lite Pro Glass Balustrade Drawings PDF

Pure Vista Ltd

Spig-Lite Pro Technical drawings (PDF)
Spig-Lite Pro Glass Balustrade Test Report (spigot system)

Spig-Lite Pro Glass Balustrade Test Report (spigot system)

Pure Vista Ltd

Lucideon Limited were commissioned by the client, Pure Vista Ltd, to carry out line load testing in accordance with BS 6180:2011 Barriers in and about buildings, to allow their balustrade system to be classified for use in accordance with the Code of Practice included within the standard. Spigot Test report for residential product suitable for 0.74kn/mtr
SPIG-LITEadvanced Installation Guide

SPIG-LITEadvanced Installation Guide

Pure Vista Ltd

An easy to follow installation guide for the SPIG-LITEadvanced balustrade.
SPIG-LITEadvanced Test Report Concrete

SPIG-LITEadvanced Test Report Concrete

Pure Vista Ltd

SPIG-LITEadvanced Test Report Steel

SPIG-LITEadvanced Test Report Steel

Pure Vista Ltd

Showing 1-29 of 29