Cyclone induction jet fan

Cyclone induction jet fan

Colt International Ltd

Colt Cyclone is a low profile, high velocity induction fan intended to control air movement in car parks and underground service areas. Cyclone reduces levels of polluted air during day to day use and assists with the extraction of smoke in the event of a fire, directing polluted air and smoke towards the extract positions in a car park or underground service area. It is tested and certified to EN 12101-3. Cyclone uses tunnel ventilation technology to eliminate the need for costly and bulky ductwork. Compared to ductwork systems, this may save car-parking spaces, reduce running costs and noise, and make the car park a lighter, less cluttered environment.
Firelight natural glazed roof ventilator

Firelight natural glazed roof ventilator

Colt International Ltd

Colt Firelight is a natural casement roof ventilator, suitable for natural day to day ventilation and smoke control. It has high aerodynamic, acoustic and thermal performance, providing extract ventilation for most kinds of industrial and commercial buildings. It is particularly suited for installation into glazing systems. Firelight conforms to EN 12101-2 and is CE marked. Firelight is manufactured under the ISO 9001 quality standard.
FM1 fire curtain

FM1 fire curtain

Colt International Ltd

A fire curtain is used where, if there is a fire, it is necessary to create a temporary barrier within an opening which seals off the area on fire. The curtain descends and prevents any fire and smoke from spreading from one area to another. It also allows people access to protected escape routes without any loss of fire resistance. A FM-1 fire curtain comprises a flexible fire-resistant fabric which is wound around a circular tube. Upon receiving a signal from the fire alarm system or on loss of power the curtain automatically unwinds to its operational position. FM-1 fire curtains have been tested as fire barriers in accordance with EN 1634-1, providing protection for a defined period and at a defined maximum temperature.
Maximising energy performance and productivity with solar shading

Maximising energy performance and productivity with solar shading

Colt International Ltd

The features and benefits of solar shading systems include optimum performance by reducing solar heat gains whilst maintaining acceptable levels of natural daylight; reduction of cooling loads in summer; reduction of heating requirements in winter; and the potential for striking aesthetic impact. Careful selection of the most appropriate solar shading system is necessary in order to achieve the necessary functional performance and to meet the aesthetic requirements of the building. Colt offers systems which consist of fixed brise soleil or controllable louvres, in vertical or horizontal configurations, made of aluminium, textile or glass fins, as well as many other types of systems.
Smoke control in single storey buildings and warehouses

Smoke control in single storey buildings and warehouses

Colt International Ltd

There are various uses to which smoke control systems can be put in the case of a fire in warehouses, factories and single storey sheds: To facilitate escape by providing smoke free escape routes. To reduce the likelihood of damage or loss to production or stock. To enable the fire-fighters to better see the fire and therefore to extinguish it more speedily and effectively. To permit greater travel distances to exits to be designed in, without the need for compartmentation, resulting in a larger or more open building plan. A well designed smoke ventilation system should be able to maintain adequate smoke free escape conditions at low level to allow the building to be evacuated with minimum risk of smoke inhalation, injury or death.
Smokemaster SM5 smoke curtain

Smokemaster SM5 smoke curtain

Colt International Ltd

A Smokemaster SM5 automatic smoke curtain prevents the movement of smoke and heat generated by a fire from one area to another by channelling or containing the smoke and heat. The smoke curtain has fixing options to suit all types of ceiling configurations and can be integrated into either a suspended or a solid ceiling. It remains hidden until required. All Colt smoke curtains conform to EN 12101-1 and are CE marked. They are available with either a D120 or a DH 120 rating, providing protection for a defined period and at a defined maximum temperature. Smokemaster smoke curtains are well suited to most industrial and commercial buildings as they are unobtrusive, moving to their active position only when needed.
Universal Louvre system

Universal Louvre system

Colt International Ltd

Colt Universal Louvre is a versatile louvre system providing either screening and/or rain defence in a wide variety of product options, materials and finishes. UL is highly resistant to weather and aerodynamically efficient, though a choice of louvre needs to be made based on the requirements of the project. 1UL is a single bank louvre system designed for screening or cladding applications when rain defence is not of primary importance. 2UL is a double bank louvre system which provides high airflow performance with a good degree of rain defence. 3UL is a triple bank louvre system designed for use where rain defence is of the utmost importance.
Ventilation systems for car parks and service areas

Ventilation systems for car parks and service areas

Colt International Ltd

Ventilation systems for car parks, loading bays and service areas are needed to achieve two objectives. Day-to-day ventilation is needed to control build-up of vehicle exhaust fumes or spilled fuel. Acceptable day-to-day air quality is maintained by removing exhaust gases produced by vehicles and by ensuring that there are no pockets of stagnant air. Smoke ventilation is needed to provide a means of clearing smoke from the car park during and after a fire. This will limit smoke temperatures and structural damage and inhibit smoke spread between floors. This leaflet: Provides an understanding of the legislative framework Explains how ventilation systems can both help meet legislative requirements and achieve design objectives Looks at the equipment options.