Apollo Waterproof Manual Call Point

Apollo's Waterproof Addressable Manual Call Point has a highly visible alarm indicator which can be seen from up to 10 metres away. When activated, the manual call point interrupts the polling cycle for a fast response and has a combined LED indicator and front reset mechanism allowing for a quick and simple reset.

  • EN 54-11 approved (EN 54-17 approved for Isolator version)
  • E-Z fit connectors
  • Front facing addressing without the need to detach the backbox
  • A unique, ergonomically designed key for resetting and front cover removal


Please Note: The Yellow Waterproof Manual Call Point is not EN 54-11 compliant as the standard permits only Red Manual Call Points be used to signal fire.

Apollo Waterproof Manual Call Point with Isolator

Apollo's Waterproof Addressable Manual Call Point has a highly visible alarm indicator which can be seen from up to 10 metres away. When activated, the manual call point interrupts the polling cycle for a fast response and has a combined LED indicator and front reset mechanism allowing for a quick and simple reset.

  • EN 54-11 approved (EN 54-17 approved for Isolator version)
  • E-Z fit connectors
  • Front facing addressing without the need to detach the backbox
  • A unique, ergonomically designed key for resetting and front cover removal


Please Note: The Yellow Waterproof Manual Call Point is not EN 54-11 compliant as the standard permits only Red Manual Call Points be used to signal fire.

Cat C Loop Powered VAD C-3-15

The VAD has been developed as a primary or supplementary alarm device for use in situations where there is a risk that sounders will not be heard. This occurs, for example, where there is a high background noise e.g. in a workshop or a machine room.

It might also be required where deaf or hearing impaired persons may be present.

  • Uses high intensity LED (white flash only)
  • EN 54-23 Compliant Category C. VAD
  • Coverage C-3-8.5 & C-3-15
  • Automatic LED check when VAD activated
  • Flash rate 0.5Hz
  • Fault signal if LED check failed
  • Locking mechanism (grub screw)
  • Wide angle of visibility
  • Synchronised with the Apollo Protocol

Cat C Loop Powered VAD C-3-8.5

The VAD has been developed as a primary or supplementary alarm device for use in situations where there is a risk that sounders will not be heard. This occurs, for example, where there is a high background noise e.g. in a workshop or a machine room.

It might also be required where deaf or hearing impaired persons may be present.

  • Uses high intensity LED (white flash only)
  • EN 54-23 Compliant Category C. VAD
  • Coverage C-3-8.5 & C-3-15
  • Automatic LED check when VAD activated
  • Flash rate 0.5Hz
  • Fault signal if LED check failed
  • Locking mechanism (grub screw)
  • Wide angle of visibility
  • Synchronised with the Apollo Protocol

Cat W Loop Powered VAD W-2.5-7

The VAD has been developed as a primary or supplementary alarm device for use in situations where there is a risk that sounders will not be heard. This occurs, for example, where there is a high background noise e.g. in a workshop or a machine room.

It might also be required where deaf or hearing impaired persons may be present.

  • Uses high intensity LED (white flash only)
  • EN 54-23 Compliant Category W. VAD
  • Coverage W-2.5-7
  • Automatic LED check when VAD activated
  • Flash rate 0.5Hz
  • Fault signal if LED check failed
  • Locking mechanism (grub screw)
  • Wide angle of visibility
  • Synchronised with the Apollo Protocol

DIN-Rail Dual Isolator

The DIN-Rail Dual Isolator provides two independent isolators which sense and isolate short circuits on Discovery and XP95 loops and spurs.

  • Loop-powered
  • Polarity sensitive
  • Up to 20 detectors can be installed between isolators
  • Allows fully isolated spurs

DIN-Rail Input-Output Unit

The DIN-Rail Input Output Unit provides a voltage free, single pole, change-over relay output, a single monitored switch input and an unmonitored, non-polarised opto-coupled input.

  • It can report fault, switch open and switch closed levels
  • Three visible LEDs
  • Loop-powered
  • Capable of switching up to 30V at 1A

DIN-Rail Interface Enclosure

DIN-Rail Interface Enclosures are available in two sizes and can be used for housing intrinsically safe (IS) barriers or DIN-Rail mounted interfaces.

A multi-purpose label that features a section for use with IS systems is supplied. For non-IS systems, the part referring to IS can simply be removed.

  • Allows multiple interfaces to be housed together
  • IP67 rated

DIN-Rail Mains Input-Output Unit

The DIN-Rail Mains Switching Input/Output Unit provides a mains-rated voltage-free, single pole change-over relay output and a monitored switch input. The unit supervises one or more normally-open switches connected to a single pair of cables.

  • It can report fault, switch open and switch closed levels
  • Three visible LEDs
  • Capable of switching up to 8A at 250V AC
  • Fits a standard 35mm DIN-Rail

DIN-Rail Output Unit

The DIN-Rail Output Unit provides a voltage-free single-pole, change-over relay output. It is a simplified version of the Input/Output unit without circuitry for monitoring inputs.

  • Capable of switching up to 30V to 1A
  • Loop-powered

DIN-Rail Sounder Controller-5 Amperes

The DIN-Rail Sounder Controller (5 Amperes) is used to control the operation of a zone of externally powered sounders and report their status to the control panel.

  • Allows sounders to be operated continuously or be pulsed, 1 second on, 1 second off
  • May be synchronised with loop sounders
  • An opto-coupled input is provided to monitor the state of the external power supply
  • Features group addressing
  • Will accept a load of up to 5A

DIN-Rail Switch Monitor

The DIN-Rail Switch Monitor is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Apollo compatible analogue control equipment.

  • Four input states - 'normal', 'fault', 'pre-alarm' and 'alarm'
  • Two visible LEDs
  • Loop-powered

DIN-Rail Switch Monitor Plus

The DIN-Rail Switch Monitor Plus is designed to monitor the state of one or more single pole, volt-free contacts connected on a single pair of cables and to report the status to Apollo compatible analogue addressable control equipment.

  • Output for resetting a remote detector
  • Four input states - 'normal', 'fault', 'pre-alarm' and 'alarm'
  • Two visible LEDs
  • Loop-powered
  • Selectable alarm delay for monitoring flow switches

DIN-Rail Zone Monitor with Isolator

The DIN-Rail Zone Monitor with Isolator controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 loop.

Discovery Carbon Monoxide Detector

The Discovery Carbon Monoxide Detector is good at detecting deep-seated fires. Please note that CO detectors do not detect smoke particles or heat and are not universal replacements for smoke detectors.

  • Enhanced detection capability
  • ideal for smouldering fires
  • Less susceptible to false alarms caused by steam than smoke detectors
  • Five response modes
  • Remote test feature

For more information, visit the CO Detector page.

Discovery CO-Heat Multisensor Detector

The Discovery CO/Heat Multisensor Detector is good at detecting deep-seated smouldering fires which give off a lot of CO as well as flaming fires. They are ideal for use in hotel bedrooms where steam may be present, dusty environments or even where simulated smoke may be present.

  • Responds to smouldering and flaming fires
  • Less susceptible to false alarms caused by steam and dust
  • Five response modes
  • Remote test feature

Discovery Heat Detector

The Discovery Heat Detector uses a single thermistor to sense the air temperature around the detector.

  • Ideal in environments that are dirty or smoky under normal conditions
  • Well suited for warehouses, loading bays and car parks
  • Unaffected by wind or atmospheric pressure
  • Five response modes
  • Remote test feature

Discovery Ionisation Detector

The Discovery Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

  • Responds well to fast-burning, flaming fires
  • Designed to operate in a variety of environments
  • Resilient to dust
  • Five response modes
  • Remote test feature

Discovery Multisensor Detector

The Discovery Multisensor Detector comprises optical smoke and thermistor temperature sensors which give both a combined signal as well as a separate heat signal for improved false alarm management.

  • Ideal for a wide range of applications
  • Enhanced false alarm management
  • Recommended, in specific modes, for hotel bedrooms and hospital wards
  • Unaffected by wind or atmospheric pressure
  • Well suited for sensitive environments
  • Five response models
  • Heat only and optical only options
  • Remote test feature

Discovery Open-Area Sounder Visual Indicator

The Discovery Open-Area Sounder Visual Indicator makes full use of the Discovery protocol and has been designed for use in indoor and open areas. When the fire system is being commissioned a 'Magnetic Wand' can be used to adjust and test each sounder locally.

  • 15 tone pairs
  • Individual control of the sounder and visual indicator
  • Volume and tone settings can be selected from the control panel
  • Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools etc.
  • Soft start option, ideal for hospitals and nursing homes
  • Group and global control for increased response time

Discovery Open-Area Voice Sounder

The Discovery Open-Area Voice Alarm Devices comprise of a sounder and a sounder visual indicator that have been designed to provide clear instructional messages through the Discovery protocol. They are loop-powered, wall mounted devices.

  • 4 pre-set message pairs, capable of up to 15 tone message pairs
  • Low current and high volume
  • Fully synchronised
  • Set up and test at point of installation

Discovery Open-Area Voice Sounder Visual Indicator

The Discovery Open-Area Voice Alarm Devices comprise a sounder and a sounder visual indicator that have been designed to provide clear instructional messages through the Discovery protocol. They are loop powered wall mounted devices.

  • 4 pre-set message pairs, capable of up to 15 tone message pairs
  • Low current and high volume
  • Fully synchronised
  • Set up and test at point of installation

Discovery Optical Smoke Detector

The Discovery Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

  • Responds well to slow-burning smouldering fires
  • Well suited for bedrooms and escape routes
  • Unaffected by wind or atmospheric pressure
  • Five response modes
  • Remote test feature

Input-Output Unit

The Input/Output Unit provides a voltage-free, double pole changeover (DPCO) relay output, a single monitored switch input and an unmonitored, non-polarised opto-coupled input.

  • It can report fault, switch open and switch closed levels
  • Three visible LED's
  • Loop-Powered
  • Capable of switching up to 30V at 1A

Intelligent Base Mounted Dual IR/UV Flame Detector

The Intelligent Base Mounted UV IR² Flame Detector is designed to protect open indoor areas such as aircraft houses, generator rooms and paint works where open flaming fires may be expected. The detector has a UV and dual IR sensors responding to different wavelengths in order to discriminate between flames and spurious sources of radiation.

  • Responds to stationary flames with no flicker
  • Sensitive to UV and low-frequency flickering IR radiation emitted by flames during combustion
  • Compact flame detector which fits into Discovery or XP95 bases
  • Loop-powered
  • False alarms due to electrical discharges from lightning or arc welding and flickering sunlight are minimised

Intelligent Base Mounted Triple IR Flame Detector

The Intelligent Base Mounted IR3 Flame Detector is designed to protect all indoor areas, even in dirty or smoky conditions where open flaming fires may be expected. The detector has three IR sensors that respond to different IR wavelengths in order to discriminate between flames and spurious sources of radiation.

  • Responds to stationary flames with no flicker
  • Sensitive to low-frequency flickering IR radiation emitted by flames during combustion
  • Compact flame detector which fits into Discovery or XP95 bases
  • Loop-powered
  • False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques

Intelligent Base Mounted UV Flame Detector

The Intelligent Base Mounted UV Flame Detector is designed to protect enclosed indoor areas where open fires may be expected. The detector has a fast acting response to flames up to 25m away and is equipped with a single UV sensor with a narrow spectral response in order to discriminate between flames and most spurious sources of radiation.

  • Responds to stationary flames with no flicker
  • Sensitive to UV radiation emitted by flames during combustion
  • Compact flame detector which fits into Discovery or XP95 bases
  • Loop-powered

Intelligent Flame Detector

The Intelligent Triple IR Flame Detector (IR3) is designed to protect areas where open flaming fires may be expected. It is sensitive to low frequency, flickering infra-red radiation emitted by flames during combustion.

  • Loop-powered
  • Sensitive to flickering IR radiation
  • Detects through films of oil, dust, water and ice
  • Responds to flickering flames, including those invisible to the naked eye
  • False alarms due to lighting or flickering sunlight are minimised
  • Compatible with Discovery and XP95 protocols

Intelligent Flameproof IR3 Flame Detector

The Intelligent Triple IR Flame Detector (IR3) is designed to protect areas where open flaming fires may be expected. It is sensitive to low frequency, flickering infra-red radiation emitted by flames during combustion.

  • Loop-powered
  • Sensitive to flickering IR radiation
  • Detects through films of oil, dust, water and ice
  • Responds to flickering flames, including those invisible to the naked eye
  • False alarms due to lighting or flickering sunlight are minimised
  • Compatible with Discovery and XP95 protocols

Intelligent Manual Call Point

The Intelligent Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the Control and Indicating Equipment using an interrupt feature within the Apollo Digital Protocol. An alarm status is indicated through the rotation of the resettable element, displaying yellow and black indication bars and a solid red LED. The manual call point can be easily reset from the front using the supplied reset key.

The Intelligent Manual Call Point will operate with compatible Apollo control equipment using the digital XP95, Discovery and CoreProtocols.

  • Resettable operating element
  • Easy access, front reset mechanism
  • E-Z fit connector system for installation
  • EN 54-11 & EN 54-17 Certified (Red version only)
  • 170° viewable LED
  • Continuity link for cable insulation testing
  • Suitable for semi flush or surface mounting

Intelligent Open-Area Sounder

The Intelligent Open-Area Sounder has been designed for use in open areas and can be connected to any Discovery or XP95 system.

  • Self-test fault monitoring
  • Choice of tones on standard device: Apollo, Slow Whoop and DIN
  • Two volume settings 92dB(A) and 100dB(A)
  • Synchronisation of tones
  • Individual and group addressing
  • Built in isolator
  • Red or white options
  • Loop-powered
  • IP65 rated

Intelligent Open-Area Sounder Visual Indicator

The Intelligent Open-Area Sounder Visual Indicator is designed for use in open areas and can be connected to an Apollo Discovery or XP95 system.

  • Self-test monitoring
  • Choice of tones on standard device: Apollo, Slow Whoop and DIN
  • Two volume settings 92dB(A) and 100dB(A)
  • Individual and group addressing
  • Synchronisation of tones and flashes
  • Built in isolator
  • Loop-powered
  • IP65 rated
  • Red and clear lens options

Intelligent Open-Area Visual Indicator

The Intelligent Open-Area Visual Indicator has been developed for use in situations where there is a risk that sounders will not be heard.

  • For use with XP95 & Discovery systems
  • Self-test fault monitoring
  • IP65 rated
  • Individual and group addressing
  • Synchronisation of flashes
  • Comes with Isolating Base as standard
  • Loop-powered
  • Red and clear lens option

Locally Powered Zone Monitor

The Locally Powered Zone Monitor powers and controls the operation of a zone of up to 40 Orbis or Series 65 detectors. It is supplied with a polycarbonate back box for surface mounting.

Loop-powered Visual Indicator - Amber

The Loop-Powered Visual Indicator is a local-area visual indicator designed for indoor use. The Visual Indicator has been developed as a supplement to sounders for use in situations where there is a risk that sounders will not be heard.

  • High intensity LEDs
  • More reliable than xenon visual indicators
  • Automatic LED check
  • Lockable
  • Wide angle of visibility
  • Enables DDA compliance
  • Synchronised flash
  • Can be used with Discovery or XP95

Loop-powered Visual Indicator - Clear Lens Red Flash

The Loop-Powered Visual Indicator is a local-area visual indicator designed for indoor use. The Visual Indicator has been developed as a supplement to sounders for use in situations where there is a risk that sounders will not be heard.

  • High intensity LEDs
  • More reliable than xenon visual indicators
  • Automatic LED check
  • Lockable
  • Wide angle of visibility
  • Enables DDA compliance
  • Synchronised flash
  • Can be used with Discovery or XP95