Loading requirements: 0.74 kN horizontal line load measured at 1100 mm above FFL with less than 25 mm deflection. 1.0 kN point load on the infill panel.
-
-
Uprights
Satin brushed grade 304 stainless steel, 42 mm diameter.
-
-
Infills
10 mm thick clear toughened float glass to EN 12150 with flat polished edges and dubbed corners.
-
-
Rails
-
-
-
Handrails
Rebated oak handrail on a square steel core rail, 42 mm diameter.
-
-
Fixing to parent structure
100 mm diameter base plate, 105 mm diameter cover rose, fixed with M10 through bolts or chemical anchors., 100 mm diameter base plate, 105 mm diameter cover rose, fixed with M10 nut and bolt or drill and tap, 100 mm diameter base plate, 105 mm diameter cover rose, fixed with M10 coach bolts.
-
-
Additional properties
Fixing
Glass fixing: D-shaped friction clamps, 4 per panel.