GypWall Twin Frame Independent - L216010 (EN)

GypWall Twin Frame Independent - L216010 (EN)

Verified 22 days ago

British Gypsum

Inner layer of Gyproc Habito 12.5mm with an outer layer of Gyproc SoundBloc F 15mm fixed to outside faces of two Gypframe 60 I 70 ‘I’ Stud frameworks with studs at 600mm centres. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 3600mm.
Sponsored
GypLyner Independent - B216025 (F) (EN)

GypLyner Independent - B216025 (F) (EN)

Verified 22 days ago

British Gypsum

One layer of Gyproc FireLine 12.5mm to one side of Gypframe 146 I 80 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216025 (E) (EN)

GypLyner Independent - B216025 (E) (EN)

Verified 22 days ago

British Gypsum

One layer of Gyproc FireLine 12.5mm to one side of Gypframe 92 I 90 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216025 (B) (EN)

GypLyner Independent - B216025 (B) (EN)

Verified 22 days ago

British Gypsum

One layer of Gyproc FireLine 12.5mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2400mm.
Sponsored
GypLyner Independent - B216025 (A) (EN)

GypLyner Independent - B216025 (A) (EN)

Verified 22 days ago

British Gypsum

One layer of Gyproc FireLine 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2400mm.
Sponsored
GypWall Single Frame - A206A255SF (B) (EN)

GypWall Single Frame - A206A255SF (B) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc SoundBloc 15mm each side of Gypframe 146 AS 50 AcouStuds at 600mm centres. 100mm and 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity with 2mm Thistle MultiFinish on each side. 60 minute EN fire height claim. For heights up to 5000mm.
Sponsored
GypLyner Independent - B216004 (B) (EN)

GypLyner Independent - B216004 (B) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc WallBoard 15mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3300mm.
Sponsored
GypLyner Independent - B216003 (E) (EN)

GypLyner Independent - B216003 (E) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 92 I 90 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypWall Twin Frame Independent - L216015 (EN)

GypWall Twin Frame Independent - L216015 (EN)

Verified 22 days ago

British Gypsum

Inner layer of Gyproc SoundBloc F 15mm with an outer layer of Gyproc Habito 12.5mm fixed to outside faces of two Gypframe 48 I 50 ‘I’ Stud frameworks with studs at 600mm centres. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 2800mm.
Sponsored
GypWall Twin Frame Independent - L216005 (EN)

GypWall Twin Frame Independent - L216005 (EN)

Verified 22 days ago

British Gypsum

Inner layer of Gyproc Habito 12.5mm with an outer layer of Gyproc SoundBloc F 15mm fixed to outside faces of two Gypframe 48 I 50 ‘I’ Stud frameworks with studs at 600mm centres. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 2800mm.
Sponsored
GypLyner Independent - B216003 (F) (EN)

GypLyner Independent - B216003 (F) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 146 I 80 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypWall Single Frame Enhanced - X606A020 (EN)

GypWall Single Frame Enhanced - X606A020 (EN)

Verified 22 days ago

British Gypsum

One layer of Gyproc DuraLine 15mm one side and an Inner layer of Gyproc WallBoard 15mm with an outer layer of Rigidur H 12.5mm the other side of Gypframe 70 AS 50 AcouStuds at 600mm centres. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4200mm.
Sponsored
GypWall Twin Frame Independent - L216018 (EN)

GypWall Twin Frame Independent - L216018 (EN)

Verified 22 days ago

British Gypsum

Inner layer of Gyproc SoundBloc F 15mm with an outer layer of Gyproc Habito 12.5mm fixed to outside faces of two Gypframe 60 I 50 ‘I’ Stud frameworks with studs at 600mm centres. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 3000mm.
Sponsored
GypWall Twin Frame Independent - L216009 (EN)

GypWall Twin Frame Independent - L216009 (EN)

Verified 22 days ago

British Gypsum

Inner layer of Gyproc Habito 12.5mm with an outer layer of Gyproc SoundBloc F 15mm fixed to outside faces of two Gypframe 60 I 50 ‘I’ Stud frameworks with studs at 600mm centres. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 3300mm.
Sponsored
GypLyner Independent - B216006 (C) (EN)

GypLyner Independent - B216006 (C) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc SoundBloc 15mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3900mm.
Sponsored
GypLyner Independent - B216004 (E) (EN)

GypLyner Independent - B216004 (E) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc WallBoard 15mm to one side of Gypframe 92 I 90 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216026 (A) (EN)

GypLyner Independent - B216026 (A) (EN)

Verified 22 days ago

British Gypsum

One layer of Gyproc FireLine 15mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2400mm.
Sponsored
GypLyner Independent - B216025 (D) (EN)

GypLyner Independent - B216025 (D) (EN)

Verified 22 days ago

British Gypsum

One layer of Gyproc FireLine 12.5mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3600mm.
Sponsored
GypLyner Independent - B216003 (C) (EN)

GypLyner Independent - B216003 (C) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3600mm.
Sponsored
GypLyner Independent - B216025 (C) (EN)

GypLyner Independent - B216025 (C) (EN)

Verified 22 days ago

British Gypsum

One layer of Gyproc FireLine 12.5mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3000mm.
Sponsored
GypLyner Independent - B216005 (C) (EN)

GypLyner Independent - B216005 (C) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc SoundBloc 12.5mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3600mm.
Sponsored
GypLyner Independent - B216006 (D) (EN)

GypLyner Independent - B216006 (D) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc SoundBloc 15mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216027 (A) (EN)

GypLyner Independent - B216027 (A) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc FireLine 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2700mm.
Sponsored
GypLyner Independent - B216027 (B) (EN)

GypLyner Independent - B216027 (B) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc FireLine 12.5mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3000mm.
Sponsored
GypLyner Independent - B216028 (F) (EN)

GypLyner Independent - B216028 (F) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc FireLine 15mm to one side of Gypframe 146 I 80 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216003 (D) (EN)

GypLyner Independent - B216003 (D) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216005 (D) (EN)

GypLyner Independent - B216005 (D) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc SoundBloc 12.5mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216028 (C) (EN)

GypLyner Independent - B216028 (C) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc FireLine 15mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3900mm.
Sponsored
GypLyner Independent - B216004 (F) (EN)

GypLyner Independent - B216004 (F) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc WallBoard 15mm to one side of Gypframe 146 I 80 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216026 (B) (EN)

GypLyner Independent - B216026 (B) (EN)

Verified 22 days ago

British Gypsum

One layer of Gyproc FireLine 15mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2700mm.
Sponsored
GypLyner Independent - B216028 (E) (EN)

GypLyner Independent - B216028 (E) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc FireLine 15mm to one side of Gypframe 92 I 90 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216028 (D) (EN)

GypLyner Independent - B216028 (D) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc FireLine 15mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216028 (B) (EN)

GypLyner Independent - B216028 (B) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc FireLine 15mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3300mm.
Sponsored
GypLyner Independent - B216004 (C) (EN)

GypLyner Independent - B216004 (C) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc WallBoard 15mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3900mm.
Sponsored
GypLyner Independent - B216026 (C) (EN)

GypLyner Independent - B216026 (C) (EN)

Verified 22 days ago

British Gypsum

One layer of Gyproc FireLine 15mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3300mm.
Sponsored
GypLyner Independent - B216003 (A) (EN)

GypLyner Independent - B216003 (A) (EN)

Verified 22 days ago

British Gypsum

Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2700mm.