Verified by manufacturer 3 months ago
Wall Cavity Fire Slab, 1000 x 600 x 75 mm
Fire and smoke barrier for masonry cavity walls.
AIM Wall Cavity Barrier (Red Edition) may be used to provide a fire barrier in masonry cavity walls as well as for fire stopping between a masonry wall system and a concrete floor slab. It is typically used vertically and horizontally to provide a fully closed cavity fire barrier along compartmentation lines in the outer leaf of the building. AIM Wall Cavity Barrier (Red Edition) may be used in different or non-standard constructions, such as rainscreen cladding systems, with the approval of a competent person.
Manufactured from foil faced high density Rockwool stone wool, and is suitable for use in masonry cavity walls. The barrier prevents the passage of heat, flame and smoke within the cavity it fills for 30, 60 or 120 minutes.
Features and benefits:
AIM Wall Cavity Barrier (Red Edition) has not been tested for use with aluminium curtain wall systems.
Color | Silver Guidance for specification option: Silver foil faced with AIM logo. |
Finish | Foil Guidance for specification option: Reinforced aluminium foil. |
Material | Stonewool |
Shape | Rectangle Other Guidance for specification option: Cut to size. Profiled. Tapered. |
Length | 1000 mm |
Width | 600 mm 1200 mm Bespoke Guidance for specification option: Cavity barrier widths are 50–600 mm. Manufacturer guidanceSlabs sizes are 1000 x 600 mm or 1000 x 1200 mm. |
Height | 75 mm 100 mm 125 mm |
Uniclass | |
CAWS | P12/310 Boards P12/360 Mineral wool rigid batts P12/40 Mineral wool rigid batts |
Product range |
Material | |
Third-party certification | IFCC 1897.Guidance for specification option: Insulation/ integrity up to 400 mm cavity. |
Facing | Foil faced. |
Fire performance | To EN 1366-4, 30 minutes insulation and integrity. |
Dimensions | 1000 x 600 x 75 mm. |
Edges | Square edge. |
Accessories | Not required. Wall cavity fire barrier fixing brackets. Barrier with a DPC. Guidance for specification option: Either loose or pre-laminated. The DPC variant has been fire tested to EN 1366-4. Barrier in a polythene sleeve. Guidance for specification option: This product variant has not been fire tested. Its use would be subject to the approval of the projects fire engineer or consultant. AIM intumescent mastic. |
Fixing clips | Small fixing clip. Guidance for specification option:
Large fixing clip. Guidance for specification option:
HD fixing clip. Guidance for specification option:
Manufacturer guidanceClips sold as separate items to quantities determined by the installer. |
Material | Stonewool |
Recyclability | Rockwool Stone Wool products may be recycled at the end of their life by Rockwool Ltd (dependent on contamination, quantity etc). |
Expected Life | 60 year |