NBS Source
I'm a manufacturer

VMZINC Fully Supported Facades - Standing Seam Cladding

Verified by manufacturer 4 months ago

VMZINC UK Third party certifications:
  • EPD

    EPD

    Certificate type

  • BRE Certificate

    BRE Certificate

    Certificate type

Standing seam cladding.

Jump to:
BOS
+44 (0)1992 921 300 Website

Application

  • Both renovations and new buildings.
  • All shapes: Flat, curved, concave, convex, conical, domes.

Description

A ventilated cladding system that can be used for both renovation and new build. As the name implies, the system consists of seams that can be crimped in a single or double lock (for greater flatness single lock seams, sometimes referred to as angle seams, are recommended). The system has a traditional look with the seams being 25 mm high. The trays can be installed horizontally, vertically and at an angle.


The façade system offers the possibility to clad all types of walls: flat, curved or complex forms. Another advantage of this zinc façade system is that it can be used on both walls and roofs, thus allowing roof and wall to blend as one (standing seam roofs require double lock seams, and are specified separately).


The cladding panels can be various sizes - it is recommended that they be no more than 4000 mm in length and 430 mm in width; consult manufacturer for details. All aspects of VMZINC can be used, with 0.8 mm being the recommended thickness for facades.


Features and benefits:

  • Covered by Code of Practice 143-5: 1964.
  • Concealed fasteners.
  • Roof to wall continuity (roofing specified separately).
  • Versatile.
  • Horizontal, vertical and diagonal (angled) installation possible.
  • 25 mm high seam.


System build-up:

  • VMZ standing seam panels in VMZINC PLUS.
  • Fixing clip.
  • 18 mm plywood or steel deck.
  • Battens creating a vented 38 mm airspace.
  • Insulation protected by VMZ Membrane.


VMZINC PLUS:

A product which allows zinc to be installed on ventilated plywood as well as specific warm (non-ventilated) substrates. The product consists of VMZINC (in all finishes) having a 60 μm coating applied to the underside thus allowing a more varied amount of substrates to be used and eliminating the risk of the formation of white rust on the underside of the zinc standing seam panels. VMZINC PLUS resists to an abrasion of 140 L when tested in accordance with ASTM D 968.


Life Cycle Analysis (LCA):

VMZINC undertakes Life Cycle Analysis (LCA) tests on its products and publishes Environmental Product Declarations (EPDs), such as BRE Environmental Profiles, available from our website www.vmzinc.co.uk and www.greenbooklive.com. These provide users with comprehensive, reliable and transparent information on relevant environmental characteristics. The information is also used by VMZINC as the basis for its eco-design approach.

General information

Color

Blue

Brown

Green

Grey

Red

Show more

Finish

Natural

Pre-treated

Material

Zinc

Shape

Rectangle

Length

430 mm

Width

4000 mm

Warranty description

50 year

Guidance for specification option:

Up to 50 year material warranty available on a project basis.

Uniclass

Ss_25_20_50_95 Zinc sheet fully supported wall-covering systemsPrimary

CAWS

H74/130 Zinc sheet fully supported wall covering

Product range

Facades

Specification data - Zinc sheet fully supported wall-covering systems

System performance

Design of zinc sheet fully supported wall covering systems

Durability

Aesthetic performance

Wall sheathing

18 mm plywood.

0.7 mm galvanized steel deck.

Manufacturer guidance

Both vented with a 38 mm cavity.

Membrane

VMZINC membrane.

Carrier

Battens creating a vented 38 mm airspace.

Substrate

18 mm plywood or steel deck.

Zinc sheet

Zinc.

Vertical joints

-

Form

Angle standing seam.

Guidance for specification option:

For greater flatness.

Double lock standing seam.

Single lock standing seam.

Fixing standing seam joints

Standing seam fixed clips

Guidance for specification option:

For panels less than 2 m in length. When using single lock all clips can be fixed.

Standing seam sliding clips

Guidance for specification option:

For longer panels sliding clips must be used towards the bottom on vertical panels and to the left and right of the centre for horizontal panels.

Manufacturer guidance

 VMZINC clips are made from 1.4301 (304) grade stainless steel and each clip must resist a pull-out force of 50 daN.

Fasteners to substrate

It is recommended that screws be used to secure the clips with three being used per sliding clip. The use of nails offers significantly less resistance, but in the event of using nails, contractors are advised to use ring shank nails.

System accessories

VMZINC PLUS continuous corner strip.

VMZINC PLUS soldered clip.

VMZINC Plus continuous folded strip.

VMZINC continuous folded strip, 0.7 mm thick.

VMZINC continuous folded strip.

VMZINC PLUS sheet clip (80 mm), 0.7 mm thick

Zinc thickness

0.8 mm.

Guidance for specification option:

VMZ Standing Seam. 0.8 mm recommended for facades.

Finish

Pre-weathered.

Natural.

Guidance for specification option:

Only available with Natural colour option.

Standard

BS EN 988, EN 15804, ASTM D 968, ISO 14001 and ISO 9001.

Size:

-

Manufacturer guidance

Maximum panel size: 430 x 4000 mm.

Weight

7 kg/m².

Fire performance

Fire classification A1 (Natural Zinc, QUARTZ ZINC, ANTHRA-ZINC and AZENGAR) and A2-s1,d0 (PIGMENTO and VMZINC PLUS) according to EN 13501-1:2002.

Product Reference

VMZINC Fully Supported Facades - Standing Seam Cladding

Colour

Natural VMZINC®.

Guidance for specification option:

Only available with Natural finish option.

Standard PIGMENTO® BLUE.

Standard PIGMENTO® GREEN.

Standard PIGMENTO® BROWN.

Standard PIGMENTO® RED.

Show more

Sustainability data

Contains Red List materials

No

Country of material origin

France

Country of product manufacture

France

Material

Zinc

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

-

Manufacturer guidance

See EN15804 EPD.

Recyclability

100%

Guidance for specification option:

Fully recyclable. 

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

20 %

Guidance for specification option:

20% (approximately).

Expected Life

100 year

Third party certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC

IFC2X3

1

Revit

Revit 2016

2

Third party certifications

EPD

EPD

EPD EN15804

BRE Certificate

BRE Certificate

BREG EPD No. R00033

Literature

VMZINC Facades - Fully Supported Facades & Rainscreen Facades July 2019

VMZINC Facades - Fully Supported Facades & Rainscreen Facades July 2019

VMZINC Standing Seam Installation Guide - Information about the Use and Detailing of VMZINC March 2018

VMZINC Standing Seam Installation Guide - Information about the Use and Detailing of VMZINC March 2018

VMZINC General Technical Recommendations - Design Guidance for Architects & Contractors.

VMZINC General Technical Recommendations - Design Guidance for Architects & Contractors.

ISO 9001

ISO 9001

VMZINC EN15804 Natural Rolled Zinc

VMZINC EN15804 Natural Rolled Zinc

ISO 14001

ISO 14001

EN15804 Pre-Weathered QUARTZ PLUS & ANTHRA PLUS

EN15804 Pre-Weathered QUARTZ PLUS & ANTHRA PLUS

BRE Certification EN15804 Pre-Weathered Rolled QUARTZ & ANTHRA

BRE Certification EN15804 Pre-Weathered Rolled QUARTZ & ANTHRA

BRE Certification EN15804 Pre-Weathered PIGMENTO & STRAT

BRE Certification EN15804 Pre-Weathered PIGMENTO & STRAT