Reflective highly breathable membrane tested in accordance with EN 13501-1 and classified as a non-combustible material (A2-s1, d0). Reflects up to 95% of heat.
Used as a breathable membrane in construction, suitable for ventilated facades, timber panels, and applications requiring fire resistance and UV stability. Can be applied in combination with photovoltaic systems or at electrical voltage points.
Traspir Alu Fire A2 430 is a reflective highly breathable membrane tested in accordance with EN 13501-1 and classified as a non-combustible material (A2-s1, d0) and reflecting up to 95% of the heat.
Features and benefits:
Color | Silver |
Finish | Reflective Foil |
Material | Aluminium Glass Fibre Polyethylene |
Shape | Other Guidance for specification option: Roll. |
Length | 35000 mm |
Width | 1200 mm |
Height | 0.43 mm Manufacturer guidanceThickness. |
Warranty description | Ten year |
Uniclass | |
CAWS | H60/235 Vapour-permeable underlay H67/290 Vapour-permeable underlay H64/22 Vapour-permeable underlay H65/235 Vapour-permeable underlay H67/24 Vapour-permeable underlay H62/235 Vapour-permeable underlay H61/22 Vapour-permeable underlay H65/22 Vapour-permeable underlay H61/235 Vapour-permeable underlay H64/307 Vapour-permeable underlay H60/22 Vapour-permeable underlay H21/20 Breather membrane H92/785 Breather membrane H22/20 Breather membrane H30/50 Breather membrane P10/320 Breather membrane H21/130 Breather membrane H22/130 Breather membrane H30/350 Breather membrane H31/280 Breather membrane H31/55 Breather membrane P10/65 Breather membrane |
SKU Code | TALUFIRE430 |
Classification data | |
Standard | To EN 13859-1 and EN 13859-2. |
Class (minimum) | W1. Guidance for specification option: Watertightness to EN 1928, Class W1. Watertightness after artificial ageing to EN 1297/ EN 1928, Class W1. Ageing conditions are tested in accordance with EN 13859-2, Annex C, extended to 5000 hours (standard 336 hours). |
Performance criteria | |
Water vapour properties | Water vapour resistance factor: 750 MNs/g (185 μ). Water vapour transmission (Sd) to EN 1931, 0.08 m. |
Fire performance | Reaction to fire to BS EN 13501-1, Class A2-s1, d0. |
Tensile properties | Tensile strength to EN 12311-1, 3000 N/ 50 mm (MD); 3200 N/ 50 mm (CD). Tensile strength after ageing to EN 1297/ EN 12311-1, 2800 N/ 50 mm (MD); 3000 N/ 50 mm (CD). Guidance for specification option: Ageing conditions are tested in accordance with EN 13859-2, Annex C, extended to 5000 hours (standard 336 hours). |
Material | Top layer: aluminium foil. Middle layer: PE functional film. Bottom layer: glass fibre fabric. |
Form | Perforated. |
Weight (minimum) | 430 g/m². |
Thickness (minimum) | 0.43 mm. |
Reflective face | Required; reflectivity to EN 15976, 95%. |
Density | 1000 kg/m³. |
Elongation | Elongation to EN 12311-1, 6% (MD); 5% (CD). Elongation after artificial ageing to EN 1297/ EN 12311-1, 6% (MD); 5% (CD). Guidance for specification option: Ageing conditions are tested in accordance with EN 13859-2, Annex C, extended to 5000 hours (standard 336 hours). |
Flexibility at low temperature | To EN 1109, -40°C. |
ThermalConductivity | 0.0007 W/(m∙K). |
Specific heat | 800 J/(kg∙K). |
Temperature resistance | -40°C to +90°C. |
UV stabilization | UV resistance without final coating to EN 13859-1/2, 5000 hours (>12 months). UV stability with joints up to 30 mm wide exposing no more than 30% of the surface to 13859-1/2, permanent. Guidance for specification option: UV resistance without final coating: Laboratory ageing test data cannot reproduce unforeseeable causes of the product's degradation, or consider the stresses to which it will be subjected during its service life. To ensure its integrity, as a precautionary measure, exposure to weather during construction should be limited to a maximum of 12 weeks. According to DTU 31.2 P1-2 (France) 5000 hours of ageing equates to a maximum exposure of 6 months during the construction phase. UV stability with joints up to 30 mm wide exposing no more than 30% of the surface: The membrane is not intended as a final waterproof layer for roofs. |
Technical characteristics, other | Resistance to nail tearing to EN 12310-1, 580 N (MC); 450 N (CD). Resistance to penetration of air to EN 12114, <0.05 m³/(m²h50 Pa). |
Material | Aluminium Glass Fibre Polyethylene |