You are viewing content for United Kingdom.
Choose a country to see content for your location. Changing region will navigate you to the homepage.
Verified by manufacturer 18 days ago
Aluminium profiled sheets
Trapezoidal roof profile.
Roof profiles that can be used to reproduce original profiled roofing shapes, or modern, bolder alternatives.
Applications include: Educational facilities, commercial premises, offices and manufacturing facilities.
Trapezoidal roof profile.
Features and benefits:
System components:
Color | Silver Guidance for specification option: Aluminium or steel. Other Guidance for specification option: Standard and bespoke/ special colours available. Manufacturer guidanceAluminium / Steel: Standard RAL Range; Contact APL for full details; Bespoke upon request Cor-Ten: Unweathered. |
Finish | Powder-coated Guidance for specification option: Class 1 or Class 2 Full RAL colour range and / or contact APL for additional finishes such as anodised-look Anodized Guidance for specification option: Contact APL for details Natural Guidance for specification option: Smooth mill-finish aluminium Unweathered Cor-Ten Embossed Guidance for specification option: Stucco-embossed mill-finish aluminium or with Armacoil™ HDP (Subject to minimum quantity) Painted Guidance for specification option: Aluminium with Armacoil™ HDP (Subject to minimum quantity) Steel with APL PUF , PRISMA or Leathergrain Plastisol Manufacturer guidancePPC, Armacoil™ HDP, Anodised, APL PUF, Stucco-Embossed Mill-Finish (SEMF), Smooth Mill Finish (MF). PRISMA, Leathergrain Plastisol |
Material | Aluminium Steel Cor-Ten |
Shape | Other Guidance for specification option: Trapezoidal Manufacturer guidanceTrapezoidal |
Length | Bespoke |
Width | 1000 mm Guidance for specification option: Cover width. |
Height | 30 mm |
Warranty description | 25 year Guidance for specification option: Cladshield™ fully-installed system warranty available; consult manufacturer for details. |
Uniclass | |
CAWS | H31/120 Metal profiled sheet self-supporting cladding/ roof covering H31/10 Metal |
Classification data | |
System performance | Manufacturer guidanceInsert requirements. |
Liner sheets | |
Material | AP22 HWR profile in 0.7 mm steel - solid, off white 80F. AP22 HWR profile in 0.7 mm steel - fully perforated, off white 80F. Guidance for specification option: Consult manufacturer for details of perforation size. AP22 HWR profile in 0.7 mm steel - web perforated, off white 80F. Guidance for specification option: Consult manufacturer for details of perforation size. AP31/1000 LP profile in 0.7 mm steel - solid, off white 80F. AP31/1000 LP profile in 0.7 mm steel - fully perforated, off white 80F. Guidance for specification option: Consult manufacturer for details of perforation size. |
Primary fasteners | Manufacturer's standard. |
End and side laps | Minimum 100 mm; APL P191/HH fixing range at one per mid span, APL P103 + P108/VCT side lap sealant range, P152 Flute Fillers. |
Air and vapour control layer | |
Material | Standard: AP22HWR Liner sheet. Acoustic: Reinforced VCL laid over stirrup (P016). Guidance for specification option: Consult manufacturer for details. |
Fasteners | APL P191/HH fixing range. Other. Guidance for specification option: Insert requirements. |
Sealing | APL P191/HH fixing range (side laps sealed with 2x runs of P108/VCT). Other. Guidance for specification option: Insert requirements. |
Spacers | Standard. Guidance for specification option: Components:
Use P912/BT50 isolating tape to top face of P030. Acoustic. Guidance for specification option: Components:
Use P912/BT50 isolating tape to top face of P030. Manufacturer guidanceConsult manufacturer for details and insert further requirements if applicable. Fixings: APL P191/HH fixing range as standard. |
Acoustic insulation | A1-rated with thickness and performance specification as required to meet performance. Guidance for specification option: Contact manufacturer for details and insert details as required. |
Thermal insulation | A1-rated. Guidance for specification option: Insert requirements; A1-rated, thickness as required to meet U-value requirement with minimum lambda of 0.040 for all calculation purposes; Allow an additional minimum of 10% of the cavity depth of soft-type insulation for compression to allow insulation to fill profile corrugations. Refer to the relevant U-value table in the supporting literature. |
External sheets | |
Material | 31/1000R aluminium profiled sheets. Guidance for specification option: Standard trapezoidal profile. 31/1000RR aluminium profiled sheets. Guidance for specification option: Trapezoidal profile with two additional mini-ribs between main peaks. Manufacturer guidanceCover width: 1000 mm. Profile width: 200 mm; height: 30 mm. 0.9 mm nominal thickness. Consult manufacturer's literature for further details. |
Primary fasteners | APL 191/LP fixing range, colour matched as required: valley fix at every corrugation at end laps and every other corrugation elsewhere. |
Secondary fixings | APL 191/LP fixing range, colour matched as required. |
End and side laps | End laps: 200 mm; APL 191/LP fixing range, colour matched as required; side laps stitched at maximum 400 mm centres; APL P103 sealant for side laps (2no runs) and end laps (3no runs); APL P152/HP Flute Fillers. Guidance for specification option: Special requirements: Clamp end lap: use P151 angle fixed to P030 as per APL standard detail; use P912/BT50 isolating tape to top face of P151. |
Fascia | |
Material | Not required. APL Slimwall™ CPS/SSF Discreet Fix system. Guidance for specification option: To be specified separately. Cross-refer to fascia system as required. |
Soffit | |
Material | Not required. APL Soffit Systems - AP 22/50-S profile. Guidance for specification option: Aluminium, steel and Cor-Ten available. APL Soffit Systems - SFP24-S profile. Guidance for specification option: Aluminium only. APL Soffit Systems - SFP42-S profile. Guidance for specification option: Aluminium only. APL Soffit Systems - CPS-SSF-S profile. Guidance for specification option: Aluminium only. Manufacturer guidanceTo be specified separately as a variant under APL Soffit Systems or omitted as required. See that system for full details, including solid/ perforated options (varies with material specified). Cross-refer to soffit system as required. |
Gutters | |
Material | Manufacturer guidanceContact manufacturer for Eavesline Gutter information; insert details or omit as required. |
Glazing | Required. Guidance for specification option: Consult manufacturer for options and insert requirements. Not required. |
System accessories | APL System Flashings. APL Clamp End Lap(s). APL Fixings (P191 & P192). APL Sealants & P152 profile flute fillers. Guidance for specification option: As manufacturer's recommendations and to match profiles. |
Colour/ Finish | Armacoil™ HDP. Guidance for specification option: Subject to minimum quantities. Insert colour required. Anodized. Guidance for specification option: Contact APL for details. Polyester powder-coating, class 1. Guidance for specification option: Insert colour/ finish required. Polyester powder-coating, class 2. Guidance for specification option: Insert colour/ finish required. Stucco-Embossed Mill-Finish (SEMF). Smooth Mill Finish (MF). Manufacturer guidanceInsert colour requirements. Consult manufacturer for further details as required. |
Recycled content (minimum) | Up to 95%. |
Liner Supports | Guidance for specification option: Subject to loadings. Centres are to general areas only, closer at high load zones. Purlins at maximum 1800 mm centres in general areas, closer at high load zone/corners. |
Profile supports | Guidance for specification option: Subject to loadings. Centres are to general areas only, closer at high load zones. To general areas: P665 brackets at maximum 1500 mm centres along each purlin, P030 fixed to every bracket; closer at high load zones/corners. |
Minimum bearing area | 50 mm with 125 mm at clap-end lap position. |
Contains Red List materials | No |
Country of product manufacture | United Kingdom |
Material | Aluminium Steel Cor-Ten |
Recyclability | High |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Guidance for specification option: Subject to substrate (steel or aluminium) and grade of aluminium |
AP 31/1000R - Aluminium- Roofing Data Sheet
AP 31/1000RR - Aluminium- Roofing Data Sheet
AP 31/1000RR - Steel - Roofing Data Sheet
AP 31/1000R - Steel - Roofing Data Sheet
APL Liner Profiles - Roofing & Cladding - Data Sheet
APL Liner Profiles - Roofing & Cladding - System Summary
APL Tritherm Spacer System - Roofing - System Summary
APL Tritherm Spacer System℗ - STEEL - Data Sheet
U-Values + Build Up - Roof - Pierce Fix
APL Armacoil™HDP + HDP-HT - Product Brochure
APL Roofing - Trapezoidal Profiles - System Summary
APL Roof Systems - System Brochure
APL SoundRoof™ and SoundWall™ - System Summary
APL Soffit System Brochure
Corrugated / Sinusoidal (19mm Deep) Profile Roof System - AP18HR-R - Sinusoidal Roof Profile System
Sinusoidal / Half-Round (40mm Deep) Profile Roof System - 45HR-R - Sinusoidal Roof Profile System
SnapLoc Standing Seam Roofing System - APL SnapLoc™ - Traditional Standing Seam Roofing System
Soffit Trapezoidal Profile & Flat Panel Systems - APL 22/50 & Slimwall™ - Soffit Profiles and Panel System
Standing Seam Roof System - AP65ZS Zipseam™ - Standing Seam System Roof Profile