Verified by manufacturer over a year ago
Two or three layer system incorporating a range of SBS-modified elastomeric bitumen membranes with a high strength polyester carrier; vapour control layers, insulation and accessories.
Total Torch membranes incorporate a special striped pattern. This advanced vapour release technology has been specially designed to dissipate any moisture vapour that may be trapped in the roofing system. When this trapped moisture begins to warm up it can form pressure pockets within the system. The Total Torch Vapour Dispersion Layer and the Total Torch Vapour Control Layer have been specially engineered to neutralize this potential problem. Once the Total Torch Vapour Control layer has been bonded to the substrate, heat is applied to its specially designed stripes onto which the insulation is fixed. Only Thermazone Torch-on insulation is approved for use within the Total Torch system, as its superior facings and dimensionally stable insulant are ideal for this form of installation.
Uniclass | |
CAWS | J41/110 Built-up reinforced bitumen membrane warm deck roof covering |
Product Reference | Total Torch Roofing System |
Preparation | Not requiredAnderson HT180 nailed layerGuidance for specification option: For timber boarded decks. Anderson HT125 Taping StripGuidance for specification option: For joints in ply/ osb decks. |
Primer | Icopal Siplast Bitumen PrimerGuidance for specification option: A quick drying primer for torch-applied membranes. Icopal SA PrimerGuidance for specification option: A-a quick drying primer for self-adhesive membranes. |
Vapour control layer | Total Torch Vapour Control LayerGuidance for specification option: Torch-applied membrane (for non combustible substrates). TorchSafe T.A. VCL StripesGuidance for specification option: Thermically activated, self-adhesive membrane. |
Insulation | Thermazone Torch-on InsulationGuidance for specification option: For partially bonded layers. |
Underlay | Total Torch Vapour Dispersion LayerGuidance for specification option: Torch-applied underlay with stripes on underside to provide partial bond. |
Top layer/ Capsheet | |
Type | Thermaweld CapsheetGuidance for specification option: Torch-applied capsheet. Tecnatorch SBS CapsheetGuidance for specification option: Torch-applied capsheet. Total Torch SBS CapsheetGuidance for specification option: Torch-applied capsheet. |
Colour | GreenBlue-greyBrownCharcoal |
Flashings and detail work | |
Underlay | TorchSafe Detailing UnderlayGuidance for specification option: 3 mm self-adhesive underlay. Premium SBS Torch On UnderlayGuidance for specification option: 2 mm polyester reinforced torch-applied underlay. Tecnatorch SBS SandGuidance for specification option: 4 mm torch-applied membrane. |
Capsheet | Thermaweld CapsheetGuidance for specification option: Torch-applied capsheet. Tecnatorch SBS CapsheetGuidance for specification option: Torch-applied capsheet. Total Torch SBS CapsheetGuidance for specification option: Torch-applied capsheet. FireSmart T.A Detailing CapsheetGuidance for specification option: Self-adhesive capsheet. |
Colour | To match field sheet |
Accessories | NoneIcopal Lightning Conductor PadsIcopal GRP Edge TrimsIcopal Roofgard Cable and Tube DuctIcopal Roofgard Cowled Telescopic VentIcopal Roofgard OutletIcopal Roofgard Parapet Outlet |
Product Options | Preparation: Consult with Icopal Ltd for details of the preparation and priming of the intended roof structure and substrate and for details of the requirements for preparation layers, venting layers, nailing layers and taping strips. System build-up: Consult Icopal Limited’s technical literature for details and guidance. |
FireSmart TorchSafe M.A. Roofing System
Power Elastomeric 250 Sand
Profiles Solo Roofing System
Profiles T.A. Warm Roofing System
Profiles XL Firesmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / MW
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / PIR - System Number 1
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / MW
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / PIR - System Number 5
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / MW - System Number 4
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / PIR - System Number 2