NBS Source
I'm a manufacturer

Application

Torch applied membrane suitable for use as a vapour control layer in bituminous, single-ply or liquid roof waterproofing systems (warm roof). The membrane is used beneath insulation and safely controls the passage of internal water vapour through the roof structure. Since the membrane adheres, it can provide a weatherproof temporary finish to the roof structure prior to the application of the final waterproofing system. It is suitable for use on both new and refurbishment projects.

Hydrocarbon solvent-based products, such as Naphtha, paraffin and creosote will have a harmful effect and should not be allowed to come into contact with these membranes.

The timber used in the construction of the roof deck must not be treated with solvent-based preservatives.

Description

An SBS-modified bituminous membrane reinforced with an extra strong glass fibre fleece with aPET film. The upper surface is finished with specially formulated low melt bitumen stripes with a silica sand coating between and has a selvedge of 75 mm and is then finished with a thermofusible film. The lower surface is finished with a thermofusible film to prevent sticking in the roll.

Features and benefits:

  • Impervious to water.
  • Unaffected by freeze/ thaw cycling. It will support temperatures from -20 to +90 °C without damage.
  • Correctly installed the product will have a life at least as long as that of the overlying roof waterproofing system.
  • The membrane is compatible with most building materials with which they are likely to come into contact with during roofing works.
  • CE marked (EN 13970, 13, 0086).

Applications:

Torch applied membrane suitable for use as a vapour control layer in bituminous, single-ply or liquid roof waterproofing systems (warm roof). The membrane is used beneath insulation and safely controls the passage of internal water vapour through the roof structure. Since the membrane adheres, it can provide a weatherproof temporary finish to the roof structure prior to the application of the final waterproofing system. It is suitable for use on both new and refurbishment projects.

Hydrocarbon solvent-based products, such as Naphtha, paraffin and creosote will have a harmful effect and should not be allowed to come into contact with these membranes.

The timber used in the construction of the roof deck must not be treated with solvent-based preservatives.

General information

Uniclass

Pr_25_57_08_75 Reinforced bitumen roofing sheetsPrimary

CAWS

J31/330 Air and vapour control layer

J41/110 Built-up reinforced bitumen membrane warm deck roof covering

J41/115 Single-layer reinforced bitumen membrane warm deck roof covering

J41/395 Air and vapour control layer

J42/110 Warm deck roof covering

J42/395 Air and vapour control layer

Specification data - Reinforced bitumen roofing sheets

Product Reference

Total Torch Vapour Control Layer

Standard product features

Technical characteristics:

  • Size (l x w): 8 x 1 m.
  • Surface: Upper: Silica sand with SBS bitumen stripes finished with thermofusible polyethene (PE) film Lower: Thermofusible PE film.
  • Material: Styrene butadiene styrene (SBS) modified bitumen.
  • Reinforcement: Glass/ Polyethylene terephthalate (PET).
  • Weight: 31 kg.
  • Thickness: 3.5 mm.
  • Mass per unit area to EN 1849-1: 3.93 kg·m².
  • Tensile strength to EN 12311-2 (A): 840 N/50 mm (MD). 550 N/50 mm (TD).
  • Elongation to EN 12311-1(A): 3.5% (MD). 3.8% (TD).
  • Vapour resistance: >3000 MN·s·g-1.
  • Equivalent air thickness: Sd = >14 m.
  • Density of moisture flow rate to EN 1931: >3.16 x 10-8 kg/(m²·s).
  • Moisture resistance factor to EN 1931: >6094 μ.
  • Reaction to fire to EN 13501-1: Class F.
  • Artificial ageing behaviour to EN 1296/EN 1931: Pass.
  • Dimensional stability to EN 1107-1 ≤ 1 %.
  • Resistance to Cold Bend to EN 1109 ≤-15°C.
  • Flow resistance at elevated temperature to EN 1110: ≥90°C.
  • Water tightness EN 1928 (B): Pass.

Similar products from BMI Group UK Ltd