NBS Source
I'm a manufacturer

ThermoFoam Enverge Nexseal LE Closed Cell Spray Foam Insulation

Verified by manufacturer 11 days ago

ThermoFoam Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

Spray foam insulation.

Jump to:
+44 (0) 1208 832602 Website

Application

Closed cell spray foam insulation suitable for:

  • Cold storage.
  • Pitched roofs.
  • Walls.
  • Attics.
  • Crawlspaces.
  • Tanks.
  • Pipe insulation.
  • Exterior applications.
  • Ducts.
  • Foundations.
  • Concrete slab.

Description

Use Cases:


The product can be used as an insulation system in the following applications:


  • Pitched Roof
  • External Wall (Interior side)
  • Suspended Floor
  • Concrete Soffits
  • Metal Roofs


The product can be installed in these assemblies based on the following detail:

  • Pitched roof insulation (low resistance roof membranes) - the product can be spray-applied between roof rafters directly to low-resistance roof membranes to create an airtight thermal insulation system. Where required, an AVCL (Air and Vapour Control Layer) or Intelligent Membrane can be installed on the warm side of the insulation to protect against interstitial condensation.
  • External Walls (interior applications only) - the product can be spray-applied between wall studs on the interior face of the wall assembly. The product can be spray-applied to masonry, timber or breathable membranes where there is adequate protection from exterior moisture ingress. Where required, an AVCL (Air and Vapour Control Layer) or Intelligent Membrane can be installed on the warm side of the insulation to protect against interstitial condensation.
  • Suspended Floors (underside of suspended floor in crawlspaces) - the product can be spray-applied between floor joists to the underside of the suspended floor deck. Where required, an AVCL (Air and Vapour Control Layer) or Intelligent Membrane can be installed on the warm side of the insulation to protect against interstitial condensation.
  • Concrete Soffits (underside of concrete slab) - the product can be spray-applied directly to the underside of a concrete soffit slab to reduce surface humidity and achieve thermal performance. When left exposed, the product may need to be covered with an intumescent coating or suitable lining. Where required, an AVCL (Air and Vapour Control Layer) or Intelligent Membrane can be installed below the insulation.


Product Description:

A spray-applied, two component, closed cell polyurethane foam insulation system, BBA certified for floor, wall and pitched roof. The product is formed by the reaction of proprietary resin blend and polymeric methylene diphenyl diisocyanate. The resin blend is comprised of Polyols, additives, fire retardants and Solstice LBA by Honeywell, which is based on hydrofluoroolefin (HFO) technology. The proprietary system is specially formulated to reduce reaction exotherm during application and provide improved dimensional stability.


The spray applied nature of Nexseal™ 2.0 LE spray foam allows the material to flow into voids and seal cracks, expanding to form a monolithic structure with high R-value (resistance to heat flow). Nexseal™ 2.0 LE spray foam can form various control layers for buildings and structures: insulation, air barrier, moisture retarder and weather barrier


Thermal Barriers:

The product must be separated from the interior of the building (occupied space) by an approved fire lining such as Gypsum plasterboard when installed into a habitable area. In non-habitable areas, the product does not need to be covered with an approved fire lining.


The product has a BS476 Part 7: Class 1 rating for surface spread of flame, the UK's only Open Cell density with this rating. A Euroclass B rating can be achieved when covered with an intumescent DC315 coating.


Product Benefits:


The product has numerous benefits over traditional pre-manufactured insulation. The product meets current Building Regulations and provides natural airtightness during installation.


  • Good thermal performance with a low thermal conductivity of 0.027 W/mK.
  • Vapour permeable to enable vapour migration through building assemblies.
  • Airtight through in-situ manufacturing and expansion of the product within the roof, wall and floor assembly.
  • Fast to install and can reduce the project timeline whilst reducing wastage and off-cuts compared to traditional insulation.
  • Low Global Warming Potential of 1 and manufactured sustainably using recycled content where possible.
  • Installed by ThermoFoam-approved applicators.



General information

Color

White

Yellow

Finish

Textured

Material

Polyurethane (PUR)

Shape

Formless

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

25 year

Uniclass

Pr_25_31_28_65 Polyisocyanurate (PIR) foam insulationPrimary

CAWS

P11/55 Polyurethane foam cavity wall stabilization system

P11/240 Polyurethane foam cavity fill

P10/205 Insulation sprayed between studs

P10/147 Polyurethane foam sprayed between rafters

Specification data - Polyisocyanurate (PIR) foam insulation

Standard

To BS EN 14315-1.

Third-party certification

British Board of Agrément (23/6963).

Apparent density

To ASTM D-1622, 2 lbs/ft³ (nominal).

Global warming potential

1.

Water absorption

To BS EN 1609: 0.41 kg/m².

Colour

Natural white/ off-white.

ThermalConductivity

0.029–0.027 W·m–1·K–1.

Guidance for specification option:

Depending on thickness.

Resistance

Mechanical Resistance and Stability: To BS EN 14315-1: 78 (kPA).

Water vapour resistance

To BS EN 12086: 62(U).

Dimensional stability

To BS EN 1604: <9%.

Sustainability data

Contains Red List materials

No

Country of material origin

United States

Country of product manufacture

United States

Recyclability

If removed from substrate, can be re-purposed and used as drainage for plant nurseries.

Manufacturer guidance

Please consult manufacturer for details.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

9.2 %

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

BBA Certificate - Nexseal LE - External Wall

BBA Agrément Certificate

BBA Agrément Certificate

BBA Certificate - Nexseal LE - Floor

Literature

Enverge Nexseal LE Closed Cell - Technical Data Sheet

Enverge Nexseal LE Closed Cell - Technical Data Sheet

Case studies

LNER Stadium, York

LNER Stadium, York

Enverge Nexseal LE Closed Cell For Concrete Soffits | ThermoFoam

Enverge Nexseal LE Closed Cell For Concrete Soffits | ThermoFoam

Why Enverge Nexseal LE Is Safer

Why Enverge Nexseal LE Is Safer

Anti-Condensation Solutions

Anti-Condensation Solutions

Similar products from ThermoFoam

ThermoFoam Enverge Sucraseal Open Cell Spray Foam Insulation

ThermoFoam Enverge Sucraseal Open Cell Spray Foam Insulation