CR-1

The Rooflight Co. Variant:

Close-coupled run of Conservation Rooflights, using multiple casements on one baseplate.

Jump to:
+44 (0)1993 833155 Website

Application

Suitable for pitched roof applications (17.5° - 65°) and can be incorporated into the roof ridge.

Description

Close-coupled run of Conservation Rooflights, using multiple casements on one baseplate.


Features and benefits:

  • Achieves a close-coupled run of rooflights by means of multiple casements mounted on one base-frame.
  • Steel frame, with a protective polyester powder coating.
  • Includes our unique Thermoliner® detail to minimise the risk of condensation and mould.
  • Silicone beading and fronting to the glazing resembles traditional putty in appearance.
  • Genuine glazing bars fitted as standard to all Studio Designer Conservation models

General information

Color

Black

Guidance for specification option:

RAL9005.

Grey

Guidance for specification option:

Light Grey (BS00A09), Dark Grey (BS00A13).

White

Guidance for specification option:

RAL9010.

Other

Guidance for specification option:

As per manufacturer and includes all RAL, BS and special colours  to match the roof covering available on request.

Finish

Powder coated to BS EN ISO 12944

Material

Glass

Steel

Shape

Rectangle

Size

Guidance for specification option:

Thirty-two standard sizes available. Sizes indicated are structural opening. Any combination of same height rooflights can be linked together using the required base frame.

Warranty description

One year

Guidance for specification option:

On ancillary items.

Five year

Guidance for specification option:

On glass.

Ten year

Guidance for specification option:

On frames upon the rooflights being registered for free online via the manufacturer website.

Uniclass

Pr_30_59_98_84 Steel frame roof window unitsPrimary

CAWS

L10/480 Roof windows

Product range

Rooflights for pitched roofs

Specification data - Steel frame roof window units

Product performance

-

Whole window U-value

1.4 W/m² K.

Frame

-

Finish as delivered

-

Coating

Polyester powder coating to BS EN 12944.

Colour

Black (RAL 9005).

Dark Grey (BS 00A13).

Light Grey (BS 00A09).

White (RAL 9010).

Any BS.

Guidance for specification option:

Insert requirement.

Any RAL.

Guidance for specification option:

Insert requirement.

As drawing.

As schedule.

Glazing or infill

-

Standard

To BS EN 1279-2.

Composition

4 mm SGG Planilux Toughened Outer, 16 mm 90% Argon Cavity, 4 mm SGG Planitherm One II (Low E) Toughened Inner.

Guidance for specification option:

Producing a glass centre pane U value of 1.0 w/m²K.

Manufacturer guidance

Enhanced glazing specification incorporating thermal, acoustic, security, light transmission, passive solar gain and decorative options available.

Drained and vented rebate

Required.

Clips or tape

Required.

Beading

Silicone beading.

Operation

-

Type

Electric operation.

Electric chain actuator.

Electric linear actuator.

Electric rack actuator.

Hand winder.

Manual operation (within reach).

Manual operation (out of reach).

Pole winder and winding crank.

Fixing features

Mounted on base frame.

Accessories

Not required.

Flashing kit.

Guidance for specification option:

Suitable for most roof types. Insert requirement.

Casement

Up to 5 casements.

Base plate

1 baseplate.

Layout

As drawing.

As schedule.

Style

Coma Collection.

Natural Plains.

Manufacturer guidance

Blind style.

Type

Not required.

Pleated Blind.

Roller Blind.

Manufacturer guidance

Blind type.

Colour

White.

Ivory.

Taupe.

Silver.

Dark Grey.

Show more

Manufacturer guidance

Blind colour.

Operation

Electric.

Manual.

Rod.

Manufacturer guidance

Blind operation.

Dimensions

Guidance for specification option:

  • Thirty Two standard sizes.
  • Sizes indicated are structural opening.
  • Any combination of same height rooflights can be linked together using the required base frame.

FrameMaterial

Steel.

Other.

Guidance for specification option:

Different material specifications (e.g. stainless steel) are available for applications in industrial or maritime locations. Consult manufacturer for details.

Electric actuators

Guidance for specification option:

  • Power requirements: depending on application.
  • The selection of actuator depends on the rooflight size and application.
  • Rain, temperature and smoke sensors are available on request.
  • An on/ off switch is required. Consult manufacturer for details.

Glazing bars

Required.

Guidance for specification option:

As standard.

Not required.

Guidance for specification option:

On request.

Third-party certification

BSI Kitemark and KM 93754.