Verified by manufacturer 12 days ago
ISO 45001 Health and Safety Management
Certificate type
ISO 9001 Quality Management
Certificate type
DoP
Certificate type
M1 emission classification
Certificate type
Rapid repair mortar for external floors.
Suitable:
STOPGAP 460 is a polymer modified, fast setting mortar for repairing external floors prior to the application of STOPGAP 850 or for use in internal applications under STOPGAP waterproof surface membranes. It has been specifically designed for use in damp conditions and has excellent freeze / thaw resistance when used in external environments.
STOPGAP 460 is dimensionally stable and is supplied as a pre-blended dry powder designed for applications between 3-50 mm. It is protein-free which allows it to be used in biologically sensitive areas.
STOPGAP 460 is suitable for use with sand/cement screeds and concrete and under STOPGAP waterproof surface membranes.
Preparation:
Color | Grey |
Finish | Smooth |
Material | Cementitious |
Shape | Formless |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Lifetime |
Uniclass | |
CAWS | C42/155 Crack repairs M51/110 Carpeting |
Third-party product certification | ISO Certified. |
Execution | Manufacturer guidanceTrowelled - consult manufacturer for details and insert requirements. |
Material | Cementious. |
Standards | To EN 1504-3:2005. Guidance for specification option: Class R2 Mortar. |
Working time | 10–15 minutes at +20°C. |
Setting time | 60 minutes at +20°C. |
Curing time | At 3 mm ready to receive covering: 24 hours. |
Consumption (per layer applied) | 1.43 kg/m² per mm thickness. |
CompressiveStrength | 20 Days: >20.0 N/mm². Manufacturer guidanceTo EN13892-2. |
Flexural strength | 5 Days: >5.0 N/mm². Manufacturer guidanceTo EN13892-2. |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | United Kingdom |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 0 Self declared |
Recyclability | No |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 0 % |