ZipSeam™ standing seam system.
Features and benefits:
System components:
Color | Silver Guidance for specification option: Aluminium or steel. Other Guidance for specification option: Standard and bespoke/ special colours available. Manufacturer guidanceAluminium / Steel: Standard RAL Range; Contact APL for full details; Bespoke upon request |
Finish | Natural Guidance for specification option: Smooth mill-finish aluminium Painted Guidance for specification option: Aluminium with Armacoil™ HDP, APL PUF or ARS (Subject to minimum quantity) Steel with APL PUF, PRISMA or Leathergrain Plastisol Embossed Guidance for specification option: Stucco-embossed mill-finish aluminium, Armacoil™ HDP, ARS or APL PUF (Subject to minimum quantity) Manufacturer guidanceArmacoil™ HDP, APL PUF, ARS, Stucco-Embossed Mill-Finish (SEMF), PRISMA or Leathergrain Plastisol |
Material | Aluminium Steel |
Shape | Other |
Length | Bespoke |
Width | 400 mm Guidance for specification option: Cover width per panel. |
Height | 65 mm |
Warranty description | 25 year Guidance for specification option: Consult manufacturer for further details. Up to 40-year warranty available on both the coating and the substrate, including for marine environments. |
Uniclass | |
CAWS | H31/120 Metal H31/10 Metal |
System performance | Manufacturer guidanceInsert requirements. |
Liner sheets | |
Material | AP22 HWR in 0.7 mm steel in off-white 80F.Guidance for specification option: Standard. AP22 HWR (acoustic)- web-perforated (R3T5E5) - 0.7 mm steel in off-white 80F.Guidance for specification option: Consult manufacturer for details of perforation size. Manufacturer guidanceLiner supports: Generally not exceeding 1500 mm maximum centre-to-centre or as illustrated on drawings - subject to loadings; for curved roofs maximum 1000 mm centres. |
Primary fasteners | APL P191/HH fixing range. |
End and side laps | Minimum 100 mm; APL P191/HH fixing range at one per mid span, APL P103 + P108/VCT side lap sealant range, P152 Flute Fillers. |
Air and vapour control layer | |
Material | AP22 HWR liner sheet.Guidance for specification option: Standard. Acoustic: Reinforced vapour control layer (VCL) laid over stirrup (P016).Guidance for specification option: Consult manufacturer for details. |
Fasteners | APL P191/HH fixing range.Guidance for specification option: Consult manufacturer for details. Other.Guidance for specification option: Insert requirements. |
Sealing | APL P191/HH fixing range (side laps sealed with two x runs of P108/VCT).Guidance for specification option: Consult manufacturer for details. Other.Guidance for specification option: Insert requirements. |
Spacers | Standard.Guidance for specification option: Components: P665 RWB, P030 Ventilated Zed with P601 structural splice as required, P647 ridge restraint strap required when pitch >7° and/ or cavity >200 mm. Halters: 75 mm long (P056-75) generally, 100 mm long (P774/100) at ridges and/ or as required by loadings, 150 mm HU-type assembly (P773/150) at eaves. Acoustic.Guidance for specification option: Components: P016 Stirrup, 665 RWB, P030 Ventilated Zed with P601 structural splice as required, P151 Clamp Endlap Angle, P647 ridge restraint strap required when pitch >7° and/ or cavity >200 mm. Halters: 75 mm long (P056-75) generally, 100 mm long (P774/100) at ridges and/or as required by loadings, 150 mm HU-type assembly (P773/150) at eaves. Manufacturer guidanceFixings: APL P191/HH fixing range with two per halter. |
Acoustic insulation | A1-rated with thickness and performance specification as required to meet performance.Guidance for specification option: Contact manufacturer for details and insert details as required. |
Thermal insulation | A1-rated, thickness as required to meet U-value requirement.Guidance for specification option: Consult manufacturer to determine thickness based on required U-value requirement. Minimum lambda of 0.040 for all calculation purposes; allow an additional minimum of 10% of the cavity depth of soft-type insulation for compression to allow insulation to fill profile corrugations. Refer to the relevant U-value table in the supporting literature. |
External sheets | |
Material | AP 65 ZS aluminium profiled sheet.Manufacturer guidanceCover width: 400 mm; pan width: 300 mm. Profile height: 65 mm. Profile supports: Generally not exceeding 1000 mm maximum centre-to-centre or as illustrated on drawings - subject to loadings - closer at corner and as required by loadings. |
Primary fasteners | Manufacturer's standard.Guidance for specification option: Use APL ZipSeam Zipper with fixed point (using P191/HH fixing) at ridge and sliding assembly using 150 mm HU halter and assembly at all eaves positions. |
Secondary fixings | Manufacturer's standard. |
End and side laps | 200 mm end lap; seal and self-drilling screws, single side lap.200 mm end lap; seal and self-drilling screws, double side lap. |
Fascia | |
Material | Manufacturer guidanceTo be specified separately as APL Slimwall™ Discreet Fix Flat Panel System (CPS/SSF) or omitted as required. Cross-refer to fascia system as required. |
Soffit | |
Material | Not required.APL Soffit Systems - AP 22/50-S profile.Guidance for specification option: Available in aluminium or steel. APL Soffit Systems - SFP24-S profile.Guidance for specification option: Available in aluminium only. APL Soffit Systems - SFP42-S profile.Guidance for specification option: Available in aluminium only. APL Soffit Systems - CPS-SSF-S profile.Guidance for specification option: Available in aluminium only. Manufacturer guidanceTo be specified separately as a variant under APL Soffit Systems or omitted as required. See that system for full details, including solid/ perforated options (these may vary based on material required). Cross-refer to soffit system as required. |
Gutters | |
Material | Manufacturer guidanceContact manufacturer for Eavesline Gutter information; insert details or omit as required. |
Support | Manufacturer guidanceInsert requirements or omit. |
Fasteners | Manufacturer guidanceInsert requirements or omit. |
Jointing | Manufacturer guidanceInsert requirements or omit. |
Glazing | Required.Guidance for specification option: Consult manufacturer for options and insert requirements. Not required. |
System accessories | GRP rooflights.Guidance for specification option: Consult manufacturer for details and insert requirements. Polycarbonate rooflights.Guidance for specification option: Consult manufacturer for details and insert requirements. |
Colour/ Finish | Armacoil™ HDP. Guidance for specification option: Subject to minimum quantities. Insert colour required. Anodized. Guidance for specification option: Contact APL for details. Polyester powder-coating, class 1. Guidance for specification option: Insert colour/ finish required. Polyester powder-coating, class 2. Guidance for specification option: Insert colour/ finish required. Stucco-Embossed Mill-Finish (SEMF). Manufacturer guidanceInsert colour requirements. |
Recycled content (minimum) | Up to 95%. |
Contains Red List materials | No |
Country of product manufacture | United Kingdom |
Recyclability | High |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | % Guidance for specification option: Subject to substrate (steel or aluminium) and grade of aluminium |
AP65ZS - Aluminium - Roofing Data Sheet
AP65ZS -Steel - Roofing Data Sheet
U-Values + Build Up - Roof - Standing Seam
APL Liner Profiles - Roofing & Cladding - System Summary
APL Liner Profiles - Roofing & Cladding - Data Sheet
APL Roofing - Zipseam™ Standing Seam - System Summary
APL Roof Systems - System Brochure
APL Armacoil™HDP + HDP-HT - Product Brochure
APL SoundRoof™ and SoundWall™ - System Summary
Corrugated / Sinusoidal (19mm Deep) Profile Roof System - AP18HR-R - Sinusoidal Roof Profile System
Sinusoidal / Half-Round (40mm Deep) Profile Roof System - 45HR-R - Sinusoidal Roof Profile System
SnapLoc Standing Seam Roofing System - APL SnapLoc™ - Traditional Standing Seam Roofing System
Soffit Trapezoidal Profile & Flat Panel Systems - APL 22/50 & Slimwall™ - Soffit Profiles and Panel System
Trapezoidal Profile (30mm Deep) Roof System - AP31/1000-R - Trapezoidal Roof Profile System