Verified by manufacturer 6 months ago
Multi layer bituminous flat roof waterproofing system with PIR insulation and self adhered bituminous AVCL on a timber deck.
For exposed roofs with a timber substrate. For other uses and substrates please see other listings or contact Soprema UK.
An underlayer with a vapour-pressure and tension dispersion system, composed of elastomer modified bitumen and a composite polyester reinforcement. PIR insulation faced with a polypropylene fleece finished bitumen glass working surface and a mineral glass facing to the under side and a self adhesive AVCL applied to a primed deck.
Membrane composed of styrene-butadiene-styrene (SBS) modified bitumen with composite polyester reinforcement. The upper surface is finished with granules, with the selvedge protected by a polypropylene film. The lower surface is protected by a micro-perforated thermofusible film with a sand/ talcum finish.
Features and benefits:
Color | Black Brown |
Finish | Sanded Guidance for specification option: / talcum. Grained Manufacturer guidanceThe upper surface is finished with granules, with the selvedge protected by a polypropylene film. The lower surface is protected by a micro-perforated thermofusible film with a sand/ talcum finish. |
Material | Styrene-butadiene-styrene (SBS) Guidance for specification option: (SBS modified bitumen.) Polyester Polypropylene Thermoplastic elastomer (TPE) Rubber |
Size | 1000 x 8000 mm |
Warranty description | 20 year |
Uniclass | |
CAWS | J41/10 Reinforced bitumen membrane warm deck roof covering J41/110 Built-up reinforced bitumen membrane warm deck roof covering J41/115 Single-layer reinforced bitumen membrane warm deck roof covering J41/12 Reinforced bitumen membrane cold deck roof covering J41/120 Built-up reinforced bitumen membrane inverted roof covering J41/125 Single-layer reinforced bitumen membrane inverted roof covering J41/130 Built-up reinforced bitumen membrane cold deck roof covering J41/135 Single-layer reinforced bitumen membrane cold deck roof covering J41/400 Built-up reinforced bitumen waterproof covering J41/405 Single-layer reinforced bitumen waterproof covering |
Product range |
Standard | To BS EN 13707. |
Class | NPD.Guidance for specification option: See technical datasheet. |
Material | |
Carrier material | Polyester. |
Bitumen modification | Elastomeric. |
Thickness (minimum) | 5 mm. |
Weight (minimum) | 5.8 kg/m². |
Surface finish | |
Top | Mineral granules with thermofusible film overlap protection. |
Underside | Macro perforated thermofusible film and sand/ talcum. |
Colour | Black.Brown. |
Third-party certification | BBA Certificate 95/3098. |
Tensile strength (to BS EN 12311-1) | Longitudinal, 1300 N/ 50 mm; Transverse, 1000 N/ 50 mm. |
Elongation at break (to BS EN 12311-1) | 35%. |
Dimensional stability | 0.3%. |
Tear resistance (to BS EN 12310-1) | 275 N. |
Flexibility at low temperature | -30°C. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 2 | |
- | 1 |
Sopralene Flam 180 AF - Bituminous Warm Flat Roof system
Sopralene Flam 180 AF - Bituminous Warm Flat Roof system on a metal deck
Sopralene Flam 180 TF
Sopralene Flam 250 AF -Bituminous Warm Flat Roof system
Sopralene Flam 250 TF
Sopralene Flam 250AF - Bituminous warm roof system on a metal deck
Sopralene Flam 250AF - Bituminous warm roof system on a timber deck
Sopralene Flam 250AF - Torch applied bituminous warm roof system on a concrete deck
Sopralene Flam Garden 250 AF
Sopralene Flam Garden 250 AF - Bituminous extensive green roof system on a concrete deck