Verified by manufacturer 3 months ago
Vertical Steel Profiled Sheets
CWCT Certificate
Certificate type
Traditional standing-seam cladding.
Wall profiles. Applications include: Educational and leisure facilities, commercial premises, offices and manufacturing facilities.
Traditional standing-seam cladding.
Features and benefits:
System components:
Color | Silver Guidance for specification option: Aluminium Other Guidance for specification option: Standard RAL Range; Contact APL for full details; Bespoke upon request Manufacturer guidanceStandard RAL Range; Contact APL for full details; Bespoke upon request |
Finish | Embossed Guidance for specification option: Stucco-embossed mill-finish aluminium or Armacoil™ HDP (Subject to minimum quantity) Painted Guidance for specification option: Aluminium with Armacoil™ HDP or SnapLoc™Aluminium-ZINC (Subject to minimum quantity) Steel with APL PUF or PRISMA Natural Guidance for specification option: Smooth mill-finish aluminium Manufacturer guidanceArmacoil™ HDP, Anodised, APL PUF, Stucco-Embossed Mill-Finish (SEMF), Smooth Mill Finish (MF), PRISMA |
Material | Aluminium Steel |
Shape | Other Guidance for specification option: APL SnapLoc™ |
Length | Bespoke |
Width | Bespoke Guidance for specification option: 250mm to 450mm modules available Manufacturer guidance250mm to 450mm modules available |
Height | 40 mm Guidance for specification option: 40mm as standard 28mm upon request Manufacturer guidance40mm as standard 28mm upon request |
Warranty description | 25 year |
Uniclass | |
CAWS | H31/10 Metal H31/110 Metal H92/120 Rainscreen cladding |
Liner sheets | |
Material | Not required.Guidance for specification option: SFS/ blockwork/ timber. AP19 LPH profile in 0.4 mm steel in off-white 80F - solid.Guidance for specification option: Where onto cladding rails. APL StrongBak™.Guidance for specification option: Long-span, non-combustible structural cladding system based upon Kassett construction principles. To be specified separately. |
Primary fasteners | APL P191/HH fixing range. |
End and side laps | Minimum 75 mm; APL P191/HH fixing range at one per mid span, APL P103 + P108/VCT sidelap sealant range, P152 Flute Fillers. |
Air and vapour control layer | |
Material | AP19 LPH Liner sheet.Guidance for specification option: Cladding rails. APL StrongBak™.Guidance for specification option: To be specified separately. Other.Guidance for specification option: SFS/Blockwork substrate/Timber - refer to relevant manufacturer. |
Fasteners | APL P191/HH fixing range.Guidance for specification option: Cladding rails. Other.Guidance for specification option: SFS/Blockwork/Timber - refer to relevant manufacturer. |
Sealing | APL P191/HH fixing range (side laps sealed with two runs of P108/VCT).Other.Guidance for specification option: SFS/ blockwork/ timber - refer to relevant manufacturer. |
Spacers | Tritherm Spacer System℗ - Fully-Filled Cavity.Guidance for specification option: Tritherm Spacer System℗ - Fully-Filled Cavity:
|
Acoustic insulation | A1-rated with thickness and performance specification as required to meet performance.Guidance for specification option: Contact manufacturer for details and insert details as required. |
Thermal insulation | Between liner/ sheathing board and decking profile: A1-rated, thickness as required to meet U-value requirement.Guidance for specification option: Minimum lambda of 0.040 for all calculation purpose; allow an additional minimum of 10% of the cavity depth of soft-type insulation for compression to allow insulation to fill decking profile corrugations; With maximum 33 kg/m³ type, use P211/ Insulation Pins with P534 Washer at three per m², bonded to liner sheet with P663 Adhesive or mechanically fixed with P191/HH fixing to TH50/56. Refer to the relevant U-value table in the supporting literature. Above decking profile/ above OSB - 30 mm Rockwool RW5.Guidance for specification option: Consult manufacturer for further details. |
External sheets | |
Material | APL SnapLoc™ 40 / module width - steel. |
Primary fasteners | APL 191/LP fixing range at top of each sheet; decking sheet with APL P191/HH fixing range in each corrugation to APZ; P719 tribar fixed at max 200 mm crs to decking profile; P716 cleat fixed with P191/CSK range with three per cleat. |
Wall glazing | Required.Not required. |
System accessories | APL System Flashings.APL Fixings (P191 & P192).APL Sealants and P152 profile flute fillers as APL recommendations and to match profiles.P744 "Snapper" for installation on SnapLoc profile.Verge closer with P152 filler block on P103/SB6 expanding foam tape. |
Liner Supports | Guidance for specification option: Subject to loadings. Centres are to general areas only, closer at high load zones.
|
Support | For decking profile onto steel cladding rails - P157 HHBs Generally not exceeding 1500 mm max c/c. Guidance for specification option: max c/c or as illustrated on drawings - subject to loadings - closer at corner and as required by loadings. For decking profile onto SFS / Blockwork - P618 tophats & P157 HHBs generally not exceeding 1200 mm max c/c. Guidance for specification option: max c/c or as illustrated on drawings - subject to loadings - closer at corner and as required by loadings For SnapLoc profile onto APL decking profile - Tribar fixed to APL decking profile at max 600 mm crs and and at each end of each sheet. |
Fixings | APL P191/HH + P191/LP + P191/CSK fixing range as required for components including P716 cleat to Tribar at max 400 mm crs and each end of each SnapLoc sheet; For RW3 insulation, use one P534/SL washer with P191/CSK fixing per board. |
Colour/ Finish: | APL PUF. Guidance for specification option: Insert colour required. Colorcoat® PRISMA Guidance for specification option: Insert colour required. LeatherGrain Plastisol Guidance for specification option: Insert colour required. Natural Galvanized Steel. Manufacturer guidanceInsert colour requirements. |
NominalThickness | 0.7 mm. |
Minimum bearing area | 50 mm for decking profile. |
Recycled content (minimum) | 85%. |
Profile supports | Manufacturer guidanceSubject to loadings. Centres are to general areas only, closer at high load zones.
|
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Recyclability | High |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | % Guidance for specification option: Subject to substrate (steel or aluminium) and grade of aluminium |
U-Values + Build Up - WALLS - Vertical Orientation to Cladding Rails
U-Values + Build Up - WALLS - Vertical Orientation to SFS / Blockwork
APL Liner Profiles - Roofing & Cladding - System Summary
APL Liner Profiles - Roofing & Cladding - Data Sheet
APL Tritherm Steel Spacer System - Cladding - System Summary
APL Tritherm Spacer System℗ - STEEL - Data Sheet
AP SnapLoc™ 40/450 - Aluminium - Roofing & Cladding Data Sheet
AP SnapLoc™ 40/450 - Steel - Roofing & Cladding Data Sheet
U-Values + Build Up - WALLS - Horizontal Orientation to Cladding Rails
U-Values + Build Up - WALLS - Horizontal Orientation to SFS / Blockwork
APL Armacoil™HDP + HDP-HT - Product Brochure
APL StrongBak™ - Cladding - System Brochure
APL Cladding Systems Brochure
APL SnapLoc™ - Cladding - System Summary
APL SnapLoc™ - Roofing & Cladding - System Brochure
APL StrongBak™ - System Summary