You are viewing content for United Kingdom.
Choose a country to see content for your location. Changing region will navigate you to the homepage.
Verified by manufacturer 17 days ago
Vertical Aluminium Profiled Sheets
CWCT Certificate
Certificate type
Traditional standing-seam cladding.
Wall profiles. Applications include: Educational and leisure facilities, commercial premises, offices and manufacturing facilities.
Traditional standing-seam cladding.
Features and benefits:
System components:
Color | Silver Guidance for specification option: Aluminium Other Guidance for specification option: Standard RAL Range; Contact APL for full details; Bespoke upon request Manufacturer guidanceStandard RAL Range; Contact APL for full details; Bespoke upon request |
Finish | Embossed Guidance for specification option: Stucco-embossed mill-finish aluminium or Armacoil™ HDP (Subject to minimum quantity) Painted Guidance for specification option: Aluminium with Armacoil™ HDP or SnapLoc™Aluminium-ZINC (Subject to minimum quantity) Steel with APL PUF or PRISMA Natural Guidance for specification option: Smooth mill-finish aluminium Manufacturer guidanceArmacoil™ HDP, Anodised, APL PUF, Stucco-Embossed Mill-Finish (SEMF), Smooth Mill Finish (MF), PRISMA |
Material | Aluminium Steel |
Shape | Other Guidance for specification option: APL SnapLoc™ |
Length | Bespoke |
Width | Bespoke Guidance for specification option: 250mm to 450mm modules available Manufacturer guidance250mm to 450mm modules available |
Height | 40 mm Guidance for specification option: 40mm as standard 28mm upon request Manufacturer guidance40mm as standard 28mm upon request |
Warranty description | 25 year |
Uniclass | |
CAWS | H92/120 Rainscreen cladding H31/110 Metal profiled sheet self-supporting cladding/ roof covering H31/10 Metal |
Classification data | |
Liner sheets | |
Material | Not required. Guidance for specification option: SFS/ blockwork/ timber. AP19 LPH profile in 0.4 mm steel in off-white 80F - solid. Guidance for specification option: Where onto cladding rails. APL StrongBak™. Guidance for specification option: Long-span, non-combustible structural cladding system based upon Kassett construction principles. To be specified separately. |
Primary fasteners | APL P191/HH fixing range. |
End and side laps | Minimum 75 mm; APL P191/HH fixing range at one per mid span, APL P103 + P108/VCT sidelap sealant range, P152 Flute Fillers. |
Air and vapour control layer | |
Material | AP19 LPH Liner sheet. Guidance for specification option: Cladding rails. APL StrongBak™. Guidance for specification option: To be specified separately. Other. Guidance for specification option: SFS/Blockwork substrate/Timber - refer to relevant manufacturer. |
Fasteners | APL P191/HH fixing range. Guidance for specification option: Cladding rails. Other. Guidance for specification option: SFS/Blockwork/Timber - refer to relevant manufacturer. |
Sealing | APL P191/HH fixing range (side laps sealed with two runs of P108/VCT). Other. Guidance for specification option: SFS/ blockwork/ timber - refer to relevant manufacturer. |
Spacers | Tritherm Spacer System℗ - Fully-Filled Cavity. Guidance for specification option: Tritherm Spacer System℗ - Fully-Filled Cavity:
|
Acoustic insulation | A1-rated with thickness and performance specification as required to meet performance. Guidance for specification option: Contact manufacturer for details and insert details as required. |
Thermal insulation | Between liner/ sheathing board and decking profile: A1-rated, thickness as required to meet U-value requirement. Guidance for specification option: Minimum lambda of 0.040 for all calculation purpose; allow an additional minimum of 10% of the cavity depth of soft-type insulation for compression to allow insulation to fill decking profile corrugations; With maximum 33 kg/m³ type, use P211/ Insulation Pins with P534 Washer at three per m², bonded to liner sheet with P663 Adhesive or mechanically fixed with P191/HH fixing to TH50/56. Refer to the relevant U-value table in the supporting literature. Above decking profile/ above OSB - 30 mm Rockwool RW5. Guidance for specification option: Consult manufacturer for further details. |
External sheets | |
Material | APL SnapLoc™ 40 / module width - aluminium. |
Primary fasteners | APL 191/LP fixing range at top of each sheet; decking sheet with APL P191/HH fixing range in each corrugation to APZ; P719 tribar fixed at max 200 mm crs to decking profile; P716 cleat fixed with P191/CSK range with three per cleat. |
Wall glazing | Required. Not required. |
System accessories | APL System Flashings. APL Fixings (P191 & P192). APL Sealants and P152 profile flute fillers as APL recommendations and to match profiles. P744 "Snapper" for installation on SnapLoc profile. Verge closer with P152 filler block on P103/SB6 expanding foam tape. |
Liner Supports | Guidance for specification option: Subject to loadings. Centres are to general areas only, closer at high load zones.
|
Support | For decking profile onto steel cladding rails - P157 HHBs Generally not exceeding 1500 mm max c/c. Guidance for specification option: max c/c or as illustrated on drawings - subject to loadings - closer at corner and as required by loadings. For decking profile onto SFS / Blockwork - P618 tophats & P157 HHBs generally not exceeding 1200 mm max c/c. Guidance for specification option: max c/c or as illustrated on drawings - subject to loadings - closer at corner and as required by loadings For SnapLoc profile onto APL decking profile - Tribar fixed to APL decking profile at max 600 mm crs and and at each end of each sheet. |
Fixings | APL P191/HH + P191/LP + P191/CSK fixing range as required for components including P716 cleat to Tribar at max 400 mm crs and each end of each SnapLoc sheet; For RW3 insulation, use one P534/SL washer with P191/CSK fixing per board. |
Colour/ Finish: | Armacoil™ HDP. Guidance for specification option: Subject to minimum quantities. Insert colour required. Stucco-Embossed Mill-Finish (SEMF). Smooth Mill Finish (MF). SnapLoc™Aluminium-ZINC. Guidance for specification option: Consult manufacturer for details. Manufacturer guidanceInsert colour requirements. |
NominalThickness | 0.9 mm. |
Minimum bearing area | 50 mm for decking profile. |
Recycled content (minimum) | Up to 95%. |
Profile supports | Manufacturer guidanceSubject to loadings. Centres are to general areas only, closer at high load zones.
|
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Aluminium Steel |
Recyclability | High |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Guidance for specification option: Subject to substrate (steel or aluminium) and grade of aluminium |
U-Values + Build Up - WALLS - Vertical Orientation to Cladding Rails
U-Values + Build Up - WALLS - Vertical Orientation to SFS / Blockwork
APL Liner Profiles - Roofing & Cladding - System Summary
APL Liner Profiles - Roofing & Cladding - Data Sheet
APL Tritherm Steel Spacer System - Cladding - System Summary
APL Tritherm Spacer System℗ - STEEL - Data Sheet
AP SnapLoc™ 40/450 - Aluminium - Roofing & Cladding Data Sheet
AP SnapLoc™ 40/450 - Steel - Roofing & Cladding Data Sheet
U-Values + Build Up - WALLS - Horizontal Orientation to Cladding Rails
U-Values + Build Up - WALLS - Horizontal Orientation to SFS / Blockwork
APL Armacoil™HDP + HDP-HT - Product Brochure
APL StrongBak™ - Cladding - System Brochure
APL Cladding Systems Brochure
APL SnapLoc™ - Cladding - System Summary
APL SnapLoc™ - Roofing & Cladding - System Brochure
APL StrongBak™ - System Summary
Concave / Half-Round Profile Wall System - AP50-Curveline™ - Concave Profile Cladding System
Corrugated / Sinusoidal (19mm Deep) Profile Wall System - AP18HR - Sinusoidal Profile Cladding System
Custom Bespoke Profile Wall Systems - AP-CBP Range - Custom Profile Cladding System
Discreet Fix Flat Panel Rainscreen Cladding System - APL Slimwall™ CPS/SSF - Rainscreen Flat Panel Cladding System
Face-Fix Flat Panel Rainscreen Cladding System - APL Slimwall™ (FF) - Flat Panel Rainscreen Cladding System
Half-Round Profile Wall System - AP50HR - Half-round Profile Cladding System
Long-span Structural Wall Panel System - APL StrongBak™ - Non-Combustible
Louvre Profile Wall Cladding System - AP70 LCP - Louvre Profile Cladding System
Louvre System - Live Louvres - APL LB3 & LB4 - Live Louvre System
Secret-Fix Flat Plank & Panel Rainscreen Cladding System - APL Slimwall™ SFP - Secret-Fix Rainscreen Panel