Verified by manufacturer 14 hours ago
Independent Wall Lining System.
Independent Wall Lining System.
The Siniat Independent Wall Lining system is a fully dry, lightweight, lining system. It is completely separated from the underlying substrate.
Ideal for commercial projects where deep continuous cavities behind boards are needed to correct or isolate substrates and accommodate services.
Finish | Other |
Material | Plasterboard Metal |
Shape | Other |
Width | Bespoke |
Height | Bespoke |
Warranty description | Lifetime Guidance for specification option: Etex Building Performance Limited offers both a comprehensive Lifetime System Warranty (excl. Aquaboard™ and Weather Defence) and External Board Warranty (Incl. Aquaboard™ - 10 Years and Weather Defence - 12 Years). For full details see the full Warranty and Proprietary Systems Policy at www.siniat.co.uk/knowledge-centre/. Etex Building Performance Limited warrants to the purchaser that the Siniat Plasterboard Solutions (“Systems”) as originally designed, built and unaltered will perform to the original laboratory performance parameters as set out in the Siniat Drywall Manual and other relevant literature as published by Siniat. The system must be constructed solely with the proprietary products and components as supplied by Siniat. The system must be installed by a professional installer in accordance with: the Siniat Drywall Manual; this specification document; CAD drawings; advice; and all relevant and applicable construction standards and regulations. |
Uniclass | |
CAWS | K10/165 Wall lining system (metal framing) K10/35 Wall lining system (metal framing) |
Linings | Inner Layer: 12.5 mm Siniat Fire Board. |
Fasteners | Inner Layer: 25 mm Siniat Self Tapping Screws at 600 mm centres. |
Joint treatment | Outer boards should be at taped and jointed using appropriate Siniat compounds to at least first stage (bedding). |
Finish | Decorative.Guidance for specification option: Siniat taping and jointing system using appropriate Siniat jointing materials and Siniat Paper Joint Tape. Consult manufacturer for further details. Non-decorative.Guidance for specification option: Outer boards should be taped and jointed using appropriate Siniat compounds to at least first stage (bedding). Consult manufacturer for further details. |
Fire resistance classification | EI 30 minutes to EN 13501-2. |
Primer/ Sealer | Siniat Drywall Sealer. Manufacturer guidanceApply undiluted across the whole drylined surface by brush or roller to coverage rate as defined by current Siniat Drywall Manual. |
Framing | Studs: 70 mm Siniat I Studs IS70/B at 400 mm centres. Guidance for specification option: Head and base track fixed to structure at maximum 600 mm centres with suitable fixing by others. |
Sealing (joints and penetrations) | Siniat Intumescent Acoustic Sealant. Guidance for specification option: Apply a 6 mm continuous bead of Siniat Intumescent Acoustic Sealant along the edges of the outer layers of plasterboard at all interfaces with the structural elements, ensuring the seal effectively eliminates air paths. All penetrations should use supporting constructions detailed in the Siniat Drywall Manual unless superseded by specific test information. For combined, warrantied performance specify FSi fire-stopping products. For cPVC pipe sealing use FSI PYROPRO(R) Sealant in place of Siniat Intumescent Acoustic Sealant. |
Height | 4.60 m. Manufacturer guidanceCold state height. |
Thickness | 95 mm. Manufacturer guidanceNominal. |
System code | IS70B(400)-212F#0. |
Standards | All products are CE marked and UKCA marked in accordance with construction products regulation. To BS EN 520, BS EN 10346, BS EN 10162, BS EN 14195 and BS EN 14566. |
Country of material origin | Spain Manufacturer guidanceApplies to the bulk material (gypsum) only. Other components are from other countries. Consult manufacturer for details. |
Country of product manufacture | United Kingdom Manufacturer guidanceUK applies to the majority of manufacture but a small percentage of finished items are imported. Contact manufacturer for details. |
Material | Plasterboard Metal |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidanceLatest EPD information available from: www.siniat.co.uk/en-gb/documentation/ |
Recyclability | Gypsum and metal components can be recycled depending on the segregation of all materials. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidanceGypsum average 33.5% and metal average 17%. |
Siniat Independent Lining System IS50R(400)-12St#0
Siniat Independent Lining System IS50R(400)-12St#0-25G
Siniat Independent Lining System IS50R(400)-212dB#0
Siniat Independent Lining System IS50R(400)-212dB#0-25G
Siniat Independent Lining System IS50R(400)-212F#0
Siniat Independent Lining System IS50R(400)-312F#0
Siniat Independent Lining System IS50R-12St#0
Siniat Independent Lining System IS50R-12St#0-25G
Siniat Independent Lining System IS50R-212dB#0
Siniat Independent Lining System IS50R-212dB#0-25G