Partitioning systems incorporating GTEC dB gypsum board, fixings, frame and finishing products. Suitable for use across many construction sectors, including commercial, residential, education and health. They offer a simple lightweight, durable and versatile means of dry wall construction.

General information
Specification data
Product Reference

Siniat GTEC dB Board Partition Systems

Partition type

ASP 003: Acoustic Stud Partition

System weight: 28 kg/m²; Thickness: 100 mm; Fire performance: 30 minutes; Strength duty: Heavy; Acoustic performance: 49 dB sound reduction.

ASP 011: Acoustic Stud Partition

System weight: 45 kg/m²; Thickness: 120 mm; Fire performance: 60 minutes; Strength duty: Severe; Acoustic performance: 57 dB sound reduction.

RSP 001: C Stud Partition

System weight: 27 kg/m²; Thickness: 80 mm; Fire performance: 30 minutes; Strength duty: Heavy; Acoustic performance: 40 dB sound reduction.

RSP 002: C Stud Partition

System weight: 23 kg/m²; Thickness: 75 mm; Fire performance: 30 minutes; Strength duty: Medium; Acoustic performance: 44 dB sound reduction.

RSP 006: C Stud Partition

System weight: 23 kg/m²; Thickness: 95 mm; Fire performance: 30 minutes; Strength duty: Medium; Acoustic performance: 40 dB sound reduction.

RSP 007: C Stud Partition

System weight: 27 kg/m²; Thickness: 100 mm; Fire performance: 30 minutes; Strength duty: Heavy; Acoustic performance: 42 dB sound reduction.

RSP 008: C Stud Partition

System weight: 27 kg/m²; Thickness: 100 mm; Fire performance: 30 minutes; Strength duty: Heavy; Acoustic performance: 46 dB sound reduction.

RSP 013: C Stud Partition

System weight: 53 kg/m²; Thickness: 130 mm; Fire performance: 90 minutes; Strength duty: Severe; Acoustic performance: 56 dB sound reduction.

RSP 017: C Stud Partition

System weight: 54 kg/m²; Thickness: 206 mm; Fire performance: 90 minutes; Strength duty: Severe; Acoustic performance: 57 dB sound reduction.

RSP 022: Twin Frame Partition

System weight: 52 kg/m²; Thickness: 295 mm; Fire performance: 60 minutes; Strength duty: Severe; Acoustic performance: 67 dB -9 Ctr sound reduction.

RSP 023: Twin Frame Partition

System weight: 60 kg/m²; Thickness: 300 mm; Fire performance: To BS 476-22: 90 minutes; to BS EN 1364-1: 60 minutes; Strength duty: Severe; Acoustic performance: 69 dB -9 Ctr sound reduction.

RSP 027: C Stud Partition

System weight: 45 kg/m²; Thickness: 100 mm; Fire performance: 60 minutes; Strength duty: Severe; Acoustic performance: 53 dB sound reduction.

RSP 028: C Stud Partition

System weight: 23 kg/m²; Thickness: 95 mm; 30 minutes; Strength duty: Medium; Acoustic performance: 45 dB sound reduction.

RSP 037: Twin Frame Partition

System weight: 86 kg/m²; Thickness: 400 mm; Fire performance: To BS 476-22: 120 minutes; to BS EN 1364-1: 90 minutes; Strength duty: Severe; Acoustic performance: 74 dB -7 Ctr sound reduction.

RSP 038: Twin Frame Partition

System weight: 54 kg/m²; Thickness: 200 mm; Fire performance: To BS 476-22: 90 minutes; to BS EN 1364-1: 60 minutes; Strength duty: Severe; Acoustic performance: 63 dB -7 Ctr sound reduction.

System height

As drawing

Insert reference.

Jointing

Insert requirement(s) from manufacturer's literature.

Sealer

GTEC Drywall Sealer

Ivory, pre-decoration coat for plasterboard.

GTEC Universal Sealer

For use on plasterboard prior to painting for improved whiteness and covering power.

Accessories

None

GTEC V-Brace

For RSP 022, RSP 023, RSP 037 and RSP 038 only.

Standard product features

GTEC dB Board:

  • Material: Aerated calcium sulfate di-hydrate with fillers and fibres enclosed inside tough liner papers with bound edges. Core and papers are bonded with starch. PVA edge glue.
  • Size (w x l): 1200 x 2400–3000 mm.
  • Nominal weight: 11–13 kg/m².
  • Thermal resistance (R-value): 0.05–0.06 m²K/W.
  • Thermal conductivity (K-value): 0.25 W/mk.

GTEC Intumescent Acoustic Sealant:

Perimeter sealing to restrict smoke, sound and fire penetration. Ensures system performance.

GTEC Corner and Edge Beads:

Provides corner and edge reinforcement.

GTEC Socket Pad:

Maintains acoustic and fire integrity at sockets.

GTEC Insulation Hold:

Secures insulation to prevent slump.

Fixings:

GTEC Self-Tapping Drywall Screws.

Product Options

Partition type:

- ASP 003: Acoustic Stud Partition:

  • Facing outer layers: One 15 mm-thick GTEC dB Board both sides.
  • Studs: Single GTEC AS70Rx Acoustic C studs at 600 mm centres.
  • Insulation: 50 mm-thick, 16 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance (to BS 476-22 and BS EN 1364-1): 30 minutes.
  • Strength duty rating (to BS 5234-2): Heavy.

- ASP 011: Acoustic Stud Partition:

  • Facing inner layers: One 12.5 mm-thick GTEC dB Board both sides.
  • Facing outer layers: One 12.5 mm-thick GTEC dB Board both sides.
  • Studs: Single GTEC AS70Rx Acoustic C studs at 600 mm centres.
  • Insulation: 25 mm-thick, 16 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance (to BS 476-22 and BS EN 1364-1): 60 minutes.
  • Strength duty rating (to BS 5234-2): Severe.

- ASP 017: Acoustic Stud Partition:

  • Facing inner layers: One 15 mm-thick GTEC dB Board both sides.
  • Facing outer layers: One 15 mm-thick GTEC dB Board both sides.
  • Studs: Single GTEC AS146Rx Acoustic C studs at 600 mm centres.
  • Insulation: 100 mm-thick, 10 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance (to BS 476-22 and BS EN 1364-1): 90 minutes.
  • Strength duty rating (to BS 5234-2): Severe.

- RSP 001: C Stud Partition:

  • Facing outer layers: One 15 mm-thick GTEC dB Board both sides.
  • Studs: Single GTEC CS50Rx C studs at 600 mm centres.
  • Fire performance (to BS 476-22 and BS EN 1364-1): 30 minutes.
  • Strength duty rating (to BS 5234-2): Heavy.

- RSP 002: C Stud Partition:

  • Facing outer layers: One 12.5 mm-thick GTEC dB Board both sides.
  • Studs: Single GTEC CS50Rx C studs at 600 mm centres.
  • Insulation: 25 mm-thick, 16 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance (to BS 476-22 and BS EN 1364-1): 30 minutes.
  • Strength duty rating (to BS 5234-2): Medium.

- RSP 006: C Stud Partition:

  • Facing outer layers: One 12.5 mm-thick GTEC dB Board both sides.
  • Studs: Single GTEC CS70Rx C studs at 600 mm centres.
  • Fire performance (to BS 476-22 and BS EN 1364-1): 30 minutes.
  • Strength duty rating (to BS 5234-2): Medium.

- RSP 007: C Stud Partition:

  • Facing outer layers: One 15 mm-thick GTEC dB Board both sides.
  • Studs: Single GTEC CS70Rx C studs at 600 mm centres.
  • Fire performance (to BS 476-22 and BS EN 1364-1): 30 minutes.
  • Strength duty rating (to BS 5234-2): Heavy.

- RSP 008: C Stud Partition:

  • Facing outer layers: One 15 mm-thick GTEC dB Board both sides.
  • Studs: Single GTEC CS70Rx C studs at 600 mm centres.
  • Insulation: 25 mm-thick, 16 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance (to BS 476-22 and BS EN 1364-1): 30 minutes.
  • Strength duty rating (to BS 5234-2): Heavy.

- RSP 013: C Stud Partition:

  • Facing inner layers: One 15 mm-thick GTEC dB Board both sides.
  • Facing outer layers: One 15 mm-thick GTEC dB Board both sides.
  • Studs: Single GTEC CS70Rx C studs at 600 mm centres.
  • Insulation: 25 mm-thick, 16 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance (to BS 476-22 and BS EN 1364-1): 90 minutes.
  • Strength duty rating (to BS 5234-2): Severe.

- RSP 017: C Stud Partition:

  • Facing inner layers: One 15 mm-thick GTEC dB Board both sides.
  • Facing outer layers: One 15 mm-thick GTEC dB Board both sides.
  • Studs: Single GTEC CS146 Rx C studs at 600 mm centres.
  • Insulation: 25 mm-thick, 16 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance (to BS 476-22 and BS EN 1364-1): 90 minutes.
  • Strength duty rating (to BS 5234-2): Severe.

- RSP 022: Twin Frame Partition:

  • Facing inner layers: One 12.5 mm-thick GTEC dB Board both sides.
  • Facing outer layers: One 12.5 mm-thick GTEC dB Board both sides.
  • Studs: Twin GTEC CS90W C studs at 600 mm centres.
  • Insulation: 100 mm-thick, 10 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance (to BS 476-22 and BS EN 1364-1): 60 minutes.
  • Strength duty rating (to BS 5234-2): Severe.

- RSP 023: Twin Frame Partition:

  • Facing inner layers: One 15 mm-thick GTEC dB Board both sides.
  • Facing outer layers: One 15 mm-thick GTEC dB Board both sides.
  • Studs: Twin GTEC CS90W C studs at 600 mm centres. GTEC V-Brace at 3000 mm centres plus extension.
  • Insulation: 100 mm-thick, 10 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance: To BS 476-22: 90 minutes; to BS EN 1364-1: 60 minutes.
  • Strength duty rating (to BS 5234-2): Severe.

- RSP 027: C Stud Partition:

  • Facing inner layers: One 12.5 mm-thick GTEC dB Board both sides.
  • Facing outer layers: One 12.5 mm-thick GTEC dB Board both sides.
  • Studs: Single GTEC CS50Rx C studs at 600 mm centres.
  • Insulation: 25 mm-thick, 16 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance (to BS 476-22 and BS EN 1364-1): 60 minutes.
  • Strength duty rating (to BS 5234-2): Severe.

- RSP 028: C Stud Partition:

  • Facing outer layers: One 12.5 mm-thick GTEC dB Board both sides.
  • Studs: Single GTEC CS70Rx C studs at 600 mm centres.
  • Insulation: 25 mm-thick, 16 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance (to BS 476-22 and BS EN 1364-1): 30 minutes.
  • Strength duty rating (to BS 5234-2): Medium.

- RSP 037: Twin Frame Partition:

  • Facing inner layers: One 15 mm-thick GTEC dB Board both sides.
  • Facing outer layers: One 15 mm-thick GTEC dB Board both sides.
  • Studs: Twin GTEC CS90W C studs at 600 mm centres. GTEC V-Brace at 3000 mm centres plus extension.
  • Insulation: Two 100 mm-thick, 10 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance: To BS 476-22: 120 minutes; to BS EN 1364-1: 90 minutes.
  • Strength duty rating (to BS 5234-2): Severe.

- RSP 038: Twin Frame Partition:

  • Facing inner layers: One 15 mm-thick GTEC dB Board both sides.
  • Facing outer layers: One 15 mm-thick GTEC dB Board both sides.
  • Studs: Twin GTEC CS50Rx C studs at 600 mm centres. GTEC V-Brace at 1500 mm vertical centres.
  • Insulation: 25 mm-thick, 16 kg/m³ density glass mineral wool (supplied by others).
  • Fire performance: To BS 476-22: 90 minutes; to BS EN 1364-1: 60 minutes.
  • Strength duty rating (to BS 5234-2): Severe.

System height (maximum):

2.75–12 m (dependent on system build-up).