Verified by manufacturer 1 month ago
IFCC
Certificate type
Open state cavity barrier.
Application and Use
Silverliner® Open State Cavity Barrier (OSCB) systems have been developed to protect the voids between the outer façade and the inner construction element of the building. The product is designed for use in a ventilated façade, with a 25 mm or 50 mm linear air gap to allow the movement of air and drainage of any moisture within the facade.
The aluminium foil restricts fibre migration and offers a class ‘0’ rating. In the event of a fire the intumescent outer edge of the product will expand and close the ventilation gap between the product and the facade preventing the passage of fire and smoke from one compartment to another.
Features and benefits:
Material | Mineral fibre Aluminium Foil |
Length | 1000 mm |
Width | Bespoke Manufacturer guidanceWidth is variable depending on building requirements; consult manufacturer. |
Height | 75 mm 120 mm Manufacturer guidanceThickness. |
Uniclass | |
CAWS | P12/360 Mineral wool rigid batts P12/40 Mineral wool rigid batts P12/41 Mineral wool rigid batts - ablative coated |
Product range |
Standard | To BS EN 1363-1.Guidance for specification option: Tested in accordance with ASFP TGD19: “Open State” Cavity Barrier used in External Envelope or Fabric of Buildings. This test method specifies a procedure for determining the fire resistance of ‘open state’ cavity barriers when subjected to the standard fire exposure conditions and performance criteria stipulated in EN 1363- 1. This method is applicable to non-loadbearing, horizontally oriented ‘open-state’ cavity barriers, which are used to provide fire separation within cavity voids such as those located between an external envelope and the face of a building. The tests have been undertaken to assess the ability of the Silverliner® OSCB systems to reinstate the fire resistance rigid/aerated concrete supporting construction. This is the standard assembly for testing such systems as performance of the barriers can then be classified. |
Third-party certification | IFCC - IFCC 1672. |
Thickness | 75 mm.120 mm. |
Facing | Faced with aluminium foil. |
Density | 80kg/m³.Guidance for specification option: Mineral fibre. |
Fire performance | Up to 120 minutes, tested in accordance with ASFP TGD 19. |
Ventilation | ≤ 5 minutes. Manufacturer guidancevoid closure time |
Volume void | ≤ 550 mm. Guidance for specification option: Total void size. |
Air Gap Volume | ≤ 50 mm. |
Fixings | Three brackets per 1000 mm at 250 mm. Guidance for specification option: Length at 390 mm or 635 mm. |
Brackets | Stainless steel. Guidance for specification option: 1.5 mm/ 0.9 mm thickness, 390 mm or 635 mm length. For product size in excess of 300 mm (W) use 635 mm. |
Country of product manufacture | United Kingdom |
Material | Mineral fibre Aluminium Foil |