Verified by manufacturer 3 months ago
A post applied, multi-layer, polyethylene membrane for below ground waterproofing and gas protection.
Suitable for use as a ground gas, hydrocarbon protection and waterproofing at ground level or below ground installations.
Sikaplan®-1653 Adhered VOC Gas Barrier is a self-adhesive version of Sikaplan®-1651 Loose VOC Gas Barrier; composed of self adhesive bitumen with an upper surface finish of Sikaplan®-1651 Loose VOC Gas Barrier and a lower surface finish of a protective siliconized polypropylene release film. It is used for the gas/ waterproofing/ tanking of underground structures where harmful ground gases are anticipated, as a post-applied fully bonded membrane.
Features and benefits:
Approvals/ standards:
For full durability and chemical resistance information, please consult manufacturer.
Color | Black |
Finish | Film Guidance for specification option: Self-adhesive bitumen surface finish covered by a protective release film. |
Material | Polyethylene Polypropylene Bitumen |
Shape | Other |
Length | 20000 mm |
Width | 1000 mm 3000 mm |
Height | 1.2 mm |
Uniclass | |
CAWS | D21/38 Gas-retardant membranes D21/350 Gas-retardant membrane J40/45 Self-adhesive bitumen gas retardant damp proofing/ tanking J40/180 Self-adhesive bitumen membranes J40/190 Self-adhesive bitumen damp proofing/ tanking J40/40 Self-adhesive bitumen membranes |
Product range |
Standard | To BS EN 13967. |
Third-party certification | British Board of Agrément (BBA) certified.Guidance for specification option: Certificate number 19/5681. |
Form | Gas-resistant tanking membrane. |
Material | |
Carrier material | High-density polyethylene (HDPE). |
Bitumen modification | Adhesive-modified bitumen. |
Gas inhibitor | Polyethylene film.Guidance for specification option: Sikaplan®-1651 VOC Gas Barrier. |
Weight (minimum) | 1350 g/m².Manufacturer guidanceTo EN 1849-2. |
Thickness (minimum) | 1.2 mm.Manufacturer guidanceTo EN 1849-2. |
Surface finishes | |
Top | Sikaplan®-1651 Loose VOC Gas Barrier. |
Underside | Siliconized polypropylene release film. |
Width | To EN 1849-2, 1 m. To EN 1849-2, 0.3 m. |
Length | To EN 1849-2, 20 m. |
Resistance to impact | To EN 12691-B, >650 mm. |
Static load resistance | To EN 12730-B, ≥20 Kg. |
Puncture resistance | To EN 12236, ≥2.0 kN. Manufacturer guidanceResistance to static puncture. |
Tensile strength (minimum) | To EN 12311-1, 550 N/50 mm (MD); 400 N/50 mm (CMD). |
Elongation to break | To EN 12310-1, >550%. Manufacturer guidanceTensile Elongation (MD and CMD). |
Tear resistance | To EN 12310-1, 300 N. Manufacturer guidanceResistance to tearing (nail shank). |
Watertightness | To EN 1928, Pass. Manufacturer guidanceWatertightness 60 kPa and 196 kPa - 20 m water head (basement application). |
Water vapour transmission | To EN 1931, 0.11–0.18 g/m²/day. |
Ageing | To EN 1296 and EN 1928, Pass. Manufacturer guidanceResistance to artificial ageing. |
Fire performance | To EN 13501-1, Class E. |
Chemical resistance | To EN 1847 and EN 1928, Pass. |
Methane permeability | To BS EN ISO 15105-1, 0.13 ml/m²/day/atm. |
Carbon dioxide permeability | To BS EN ISO 15105-1, 3.01 ml/m²/day/atm. |
Radon permeability | To K124/02/95, 1.0 x 10-¹² m²/s. |