NBS Source
I'm a manufacturer

SikaFiber® Novocon® HE-1060 HT - High Tensile Steel Fibres For Concrete

Verified by manufacturer 26 days ago

Sika Limited

High tensile steel fibres for concrete.

Jump to:
+44 (0)1707 394444 Website

Application

  • Ground supported slabs.
  • Suspended floors.
  • Jointless floors.
  • External roads and pavements.
  • Precast.
  • Overlays.
  • Walls.
  • Blast-resistant concrete

Description

SikaFiber® Novocon® HE-1060 HT (GB) steel fibres are designed specifically for the reinforcement of concrete, mortars and other cementitious mixes. SikaFiber® Novocon® HE-1060 HT (GB) is a cold drawn wire fibre, deformed with hooked ends to provide optimum performance within the concrete mix.


Features and benefits:

  • Provides uniform multi-directional concrete reinforcement.
  • Increases crack resistance, ductility, energy absorption or toughness of concrete.
  • Improves impact resistance, fatigue endurance and shear strength of concrete.
  • High tensile strength fibre bridging joints and cracks to provide tighter aggregate interlock resulting in increased load carrying capacity.
  • Provides increased ultimate load bearing capacity which allows possible reduction of concrete section.
  • Requires less labour to incorporate into concrete than conventional reinforcement.
  • Offers economical concrete reinforcement solutions with greater project scheduling accuracy.
  • Suited for hand or vibratory screeds, laser screeds and all conventional finishing equipment.

General information

Material

Steel

Fibre

Shape

Other

Length

60 mm

Uniclass

Pr_20_31_01_85 Stainless steel fibresPrimary

CAWS

E11/435 Proprietary admixture

E10/418 Proprietary admixture

Product range

Fibres for concrete

Specification data - Stainless steel fibres

Standard

To BS EN 14889-1.

Material group

I.

Fibre properties (minimum)

-

Tensile strength (Rm)

1500 N/mm².

Dimensions

-

Length

60 mm.

Aspect ratio

57.

Shape

Hook-end.

Dosage

20—40 kg/m³.

Guidance for specification option:

Sika technical staff can offer advice on dosage once performance requirements have been established by the project designer/engineer.

Manufacturer guidance

Typical dosage.

Diameter

1.05 mm.

Manufacturer guidance

Equivalent diameter.