SECUR-DOR 4 Double

SECUR-DOR 4 Double

Robust UK Ltd Third party certifications:
  • QA Certificate

    QA Certificate

    Certificate type

Intruder and blast resistant, double leaf security doorset.

Jump to:
+44 (0)1782 592900 www.robust-uk.com

Application

For protecting medium to high risk properties from experienced attempts at forced entry, regardless of noise, using heavy hand and battery tools or explosives.

Description

Double leaf, single swing, security and blast door.


Features and benefits:

  • Conforms to BS EN 1627 RC4.
  • Explosive resistance (to BS EN 13124-2): Up to EXR2.
  • Thermal transmittance 2.9 W/m²K.

General information

Finish

Polyester powder coated

Unfinished

Material

Zinc

Corrosion resistant zintek®/ Aluzinc sheets.

Shape

Rectangular

Size

2700 x 2800 mm

Uniclass 2015

Pr_30_59_24_37 High-security doorsetsPrimary

CAWS

L20/480 Doorsets

L20/515 Blast resistant door

L20/55 Doorsets

Specification data - High-security doorsets Enhanced data

Security performance

To ENV 1627, level 4.

Frame

Folded and welded from 3 mm thick zintek®/ Aluzinc sheets.

 Type C or D.

Door leaf

-

Thickness

48 mm.

Locking mechanism

Centre high security sashlock.

Combined with two similar deadlocks in the upper and lower quarters of the door.

Accessories

[-] Insert requirements.

Execution

Installing hardware.

Product Reference

SECUR-DOR 4 Double

Configuration

Equal split, latched.

Equal split, unlatched.

Unequally split, latched.

Unequally split, unlatched.

Finish/ Colour

Polyester powder coated, non-standard colour range.

Insert colour requirement.

Polyester powder coated, standard colour range.

Standard, insert colour requirement.

Unfinished.

For site finishing.

Profile

Frame profile.

Type C.

95 mm depth.

Type D.

145 mm depth.

Ironmongery

Manufacturer's standard.

MICO Tindall hardware.

Insert requirements.

Surelock McGill hardware.

Insert requirements.

Three-point, heavy duty panic hardware.

For fire escape.

Thermal transmittance (U-Value)

2.9 W/m²K.

Threshold

15 mm rebated.

DDA compliant.

Ballistic performance

Explosion resistance.

To BS EN 13124-2, up to EXR2.

Environmental information

Contains Red List materials

No

Country of material origin

United Kingdom

Recyclability

98%

Recycled content

New materials only.

-

Third party certifications

  • Loss Prevention Certification Board (LPCB): Certified

Similar products from Robust UK Ltd