NBS Source
I'm a manufacturer
Compare variants

Sealwall - Precast Concrete Elements

Verified by manufacturer 3 months ago

4.3 m

Naylor Concrete Products Ltd Variant:

Precast concrete elements for forming liquid retaining walls.

Jump to:
01226 320810 Website

Application

  • Storm overflow.
  • PST and FST.
  • Humus.
  • Sewage aeration.
  • Potable water.
  • Irrigation tanks.
  • Chemical and effluent storage.

Description

Precast concrete elements used to form liquid retaining walls for construction, either above or below ground. Division walls are available to form compartments or launder channels within the tank.

Available up to 4 m finished heights, panels are secured in temporary state via panel-to-panel fixings with in situ base and ring beams to 300 mm base of units.

Completed square tanks can be covered using pre-stressed sections. Panels are supplied with fixings, seals and steel for ring beams.


Features and benefits:

  • Can be adapted to form rectangular or circular shapes with unlimited capacity.
  • Reduction in build time and overall construction costs.
  • The jointing system ensures a watertight and secure connection between adjacent panels.
  • Integrated Hydrotite seals ensure compliance with BS 8007 and BS 8110.


Applied with hand trowel.

General information

Color

Grey

Finish

Smooth

Material

Concrete

Shape

Rectangle

Circle

Width

1050 mm

Height

3300 mm

3800 mm

4300 mm

Uniclass

Pr_20_93_71_53 Modular reinforced concrete stem wall unitsPrimary

CAWS

D41/410 Precast reinforced concrete stem walls

Product range

Precast

Specification data - Modular reinforced concrete stem wall units

Configuration

L shape.

Dimensions

-

Height

4300 mm.

Width

1050 mm.

Depth

Manufacturer's standard.

Weight

Manufacturer's standard.

Finish

-

Exposed faces

Plain finish.

Concealed faces

Plain finish.

StrengthClass

C50.

Accessories

Guidance for specification option:

Insert requirement, contact manufacturer for information.

Design

As drawing.

Guidance for specification option:

Insert drawing reference number where applicable. Apertures can be cast in to suit requirements. Consult manufacturer for information.


Standard build includes packers (onto which the units are placed), hydrophilic strips (sealing between units), securing bolts and washers (to connect units) and steel bar continuity reinforcement (through preformed holes in the unit base) which, along with further loose reinforcement, are cast into an external concrete ring beam.

Colour

Light grey.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

0.19 kg CO₂ eq/kg

Self declared