Rockfon® Samson™

Rockfon® Samson™

Rockfon

Tiles have a high impact resistant surface, especially suited for areas with a high activity level, e.g. schools and sports halls.

Jump to:
+44 (0)208 2227457 www.rockfon.co.uk
Description

Tiles have a high impact resistant surface, especially suited for areas with a high activity level e.g. schools and sports halls.

The sound absorption level is exceptional; thereby contributing to a good acoustic environment in what typically can be noisy application areas.

For maximum impact resistance use with Rockfon System Samson . In areas where the requirement for impact resistance is lower, Samson can also be installed in RockLink 24 with clips or retaining channels.

General information

Uniclass 2015

Pr_35_93_13_53 Mineral fibre infill unitsPrimary

CAWS

K40/10 Suspended ceilings

K40/115 Unit/ modular suspended ceiling system

K40/265 Infill units

Specification data - Mineral fibre infill units

Product Reference

Rockfon® Samson™

Module size

600 x 600 mm

1200 x 600 mm

1200 x 1200 mm

1800 x 600 mm

2400 x 600 mm

Edges

A24

AEX

Acoustic fireboxes

Not required

700 x 700 x 200 mm

1300 x 700 x 200 mm

Standard product features

Surface finish:

  • Visible side: Durable woven surface with painted edges.
  • Rear side: Back fleece.

Sound absorption:

To ISO 11654: 1.00 αw. Class A.

Reaction to fire:

To BS EN 13501-1, Class A1.

Fire performance:

Some sizes and edge details of Rockfon® Samson™ can be used with various Chicago Metallic grids and Rockfon systems to create a 60 minutes fire protecting ceiling in accordance with BS 476 Part 21 and Part 23. They can also be used to create a 30 minutes fire protecting membrane ceiling (integrity only) in accordance with BS 476 Part 22 – consult manufacturer for details.

Humidity resistance and dimensional stability:

  • Dimensionally stable, even at humidity levels of up to 100% RH.
  • As the humidity inside a building has no influence on Rockfon ceiling tiles, the ceiling can be installed at all temperatures ranging from 0-40ºC. No acclimatisation is necessary.
  • Retains superior properties even in infrequently heated and unheated rooms.
  • Precautions should be taken to avoid condensation risks.
  • In accordance with BS EN 13964, predominantly classified as class 1/C/0N. Certain module sizes are class 2/C/0N.

Light reflection:

72%.

Thermal conductivity:

In accordance with EN 12667: Minimum thickness 30 mm, measured λD = 37 W/mK.

Demounting:

  • Rockfon tiles with A24 edges can be demounted.
  • Rockfon tiles with AEX edges cannot be demounted.

Cleaning:

  • Can be vacuum cleaned with a soft brush attachment.
  • Stone wool is an inorganic material which is not attacked by rot, fungi or bacteria. This makes for a cleaner and healthier indoor environment.

Impact resistance:

Tested for mechanical impact resistance while directly mounted in System OlympiaPlus A and meets the requirements of Class A1 in accordance with EN 13964 Annex D.

Emissions:

Awarded the Finnish M1 emission classification for building materials and the Danish Indoor Climate Label for low VOC emission products.

Compatible edges, grids and systems:

  • A24: Use with Chicago Metallic T24 2890 Click Grid to create Rockfon® System T24 A™.
  • AEX: Use with Chicago Metallic Olympia Bandraster to create Rockfon® System Olympia Plus A Impact 1A