High-specification chemically-resistant (No Foil) co-extruded multi-layer barrier providing exceptional protection on construction sites contaminated by VOCs, hydrocarbons, and ground gases.
Rhinoplast Evolution HD Gas Barrier is our highest specification chemically resistant co-extruded multi-layer membrane engineered to provide exceptional protection on construction sites contaminated by volatile organic compounds, hydrocarbons, and ground gases such as methane, radon, and CO2. Additionally, this high-performance membrane doubles as a damp proof membrane resistant to water moisture.
Developed with the latest co-extrusion technology, Rhinoplast Evolution HD uses virgin-grade high-performance engineering polymers, forming a fourteen-layer barrier that includes two layers of gas vapour resistant barrier polymer EVOH, encased in high-density polyethylene (HDPE) outer layers, achieving an overall thickness of 0.6mm.
This innovative construction provides outstanding robustness and performance without the need for aluminium foil or reinforcement allowing it to be installed in direct contact with concrete without risk of corrosion while ensuring the highest level of protection against harmful gas ingress.
Features and benefits:
Color | Brown |
Finish | Smooth |
Material | High density polyethylene (HDPE) Polymer Guidance for specification option: Ethylene vinyl alcohol (EVOH). |
Shape | Rectangle |
Length | 30500 mm |
Width | 1650 mm |
Height | 0.6 mm Guidance for specification option: Thickness. |
Uniclass | |
CAWS | J40/35 Loose-laid plastics or rubber gas-retardant membranes J40/20 Loose-laid plastics or rubber sheet damp-proofing J40/297 Waterproofing/ damp-proofing/ gas-retardant membrane J40/140 Loose-laid plastics or rubber sheet gas-retardant membranes J40/120 Loose-laid plastics or rubber sheet damp-proofing |
Material | High-density polyethylene (HDPE)/ ethylene vinyl alcohol co-polymer (EVOH). |
Purpose | Meets NHBC Foundation’s NF94 guidance for use in Type A, Type B and Type C membrane locations. Radon Amber 1/ Amber 2 gas barrier. Damp-proof membrane. |
Standard | CE marked for waterproofing to EN 13967:2012+A1:2017. |
Performance characteristics | |
Tensile strength (minimum) | To DIN EN 12311-2/ DIN EN ISO 291-23/50-2, machine direction (MD) 376 N/50mm; cross direction (CMD) 375 N/50mm. |
Tear resistance | Trouser strength - BBA Test Method, machine direction (MD) 234 N; cross direction (CMD) 230 N. Guidance for specification option: Nail shank. |
Elongation to break | To DIN EN 12311-2/ DIN EN ISO 291-23/50-2, machine direction (MD): 300%; cross direction (CMD) 100%. |
Resistant to underground gases | Methane, radon, carbon dioxide, other. Guidance for specification option: Consult manufacturer's literature for transmission rates for: Benzene; toluene, ethyl benzene; xylene; hexane; tetrachloroethene (PCE); trichloroethene (TCE); naphthalene. |
Water vapour resistance (minimum) | Manufacturer's standard. |
Fire performance | Reaction to fire to EN 13501-1, Class E. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | None – virgin material. |
Form | 14 layers. |
Physical properties | |
Colour | Brown. |
Weight (minimum) | Mass to DIN EN 1849-2/ ISO 9864, 580 g/m². |
Dimensions | |
Thickness (minimum) | 0.6 mm. Guidance for specification option: To DIN EN 1849-2. |
Width (minimum) | 1650 mm. Guidance for specification option: To DIN EN 1848-2. Manufacturer guidanceArea per roll: 100 m². |
Roll length (minimum) | 30.5 m. Guidance for specification option: To DIN EN 1848-2. Manufacturer guidanceArea per roll: 100 m². |
Watertightness | To DIN EN 1928 - Method B, watertight/ pass (at 60 kPa - 24 h and 500 kPa - 72 h). |
Resistance to impact | To DIN EN 12691 - 350 mm drop, watertight/ pass. |
Static load resistance | To DIN EN 12730, 20 kg (pass). |
Durability | Against thermal ageing at 60 kPa to DIN EN 1928, watertight/ pass. |
Shear resistance of joints (to EN 12317-2) | To DIN EN 12317-2, machine direction (MD) 228 N/50mm; cross direction (CMD) 166 N/50mm. |
Water vapour permeability | To DIN EN 1931 - Method B, 0.054 g/m²/day. |
Carbon dioxide transmission rate | To ISO 15105-1, 0.37 mL/m²/day/atm. |
Methane transmission rate | To ISO 15105-1, ≤0.09 mL/m²/day/atm. |
Radon permeability | To SP method 3873, 1.2E-12 m²/s. |
Accessories | None. Rhinoplast GR single-sided detail lap tape. Guidance for specification option: 75 mm wide, 20 m roll. Rhinoplast LT Jointstrip double-sided tape. Guidance for specification option: 50 mm wide, 15 m roll. Rhinoplast gas resistant detailing strip. Guidance for specification option: 300 mm wide, 20 m roll. Rhinoplast butyl joint tape. Guidance for specification option: 100 mm wide, 15 m roll. Manufacturer guidanceConsult manufacturer's literature for details. |
Material | High density polyethylene (HDPE) Polymer Guidance for specification option: Ethylene vinyl alcohol (EVOH). |
Evolution GAS DPC - Gas Resistant Damp-Proof Course (DPC)