Verified by manufacturer 6 days ago
Polymer-engineered high-performance damp-proof course (DPC) with an embossed surface. Tough, flexible and suitable for cavity trays and as a radon DPC barrier.
An innovative, bitumen-free damp-proof course (DPC) that combines the latest polymer technology to surpass traditional British Standard DPCs as a horizontal, vertical or stepped damp proof course.
Suitable for unsupported cavity trays for sealing cavities to deflect downward movement of water in external cavity walls with masonry inner or outer leaves and timber frame construction.
Engineered for durability and flexibility to allow site forming for built in or face fix applications to residential and commercial construction types.
Designed to prevent moisture and radon gas ingress, providing a robust barrier allowing continuity with membranes offering whole footprint coverage.
Feature and benefits:
Color | Black |
Finish | Embossed |
Material | Polymer |
Shape | Rectangle |
Length | 20000 mm |
Width | 100 mm 112 mm 150 mm 225 mm 300 mm |
Height | 0.8 mm Guidance for specification option: Thickness. |
Uniclass | |
CAWS | F30/360 Gas-resistant damp-proof courses/ cavity trays F30/54 Gas-resistant dpcs/ cavity trays |
Material | Elastomeric polymer. |
Compatibility | Suitable for use with adjoining gas-resistant dpms. |
Colour | Black. |
Thickness | 0.8 mm. Guidance for specification option: To EN 1849-2. |
Roll width | 100 mm. 112 mm. 150 mm. 225 mm. 300 mm. Manufacturer guidanceTo EN 1849-2. |
Roll length | 20 m. Guidance for specification option: To EN 1849-2. |
Weight | To EN 1849-2, 749 g/m². |
Reaction to fire | To EN 13501-1, Class E. |
Watertightness | To EN 1928, pass (at 2 kPa). |
Water vapour permeability | To EN 1931, 0.13 g/m²/day. |
Resistance to impact | To EN 12691 - Method B, ≥600 mm. |
Tensile strength | To EN 12311-1, machine direction (MD) 514 N/50mm; cross direction (CMD) 413 N/50mm. |
Elongation | At break, to EN 12311-1, machine direction (MD) 570%; cross direction (CMD) 610%. |
Static load resistance | To EN 12730, 20 kg (pass). |
Flexibility at low temperature | To EN 495-5 resistance to lower temperature flexibility, ≤-40°C. |
Durability | Against ageing to EN 1926/ EN 1928, pass. |
Shear resistance of joints (to EN 12317-2) | Machine direction (MD) 449 N; cross direction (CMD) 520 N. |
Tear resistance | To EN 12310-1, machine direction (MD) 370 N; cross direction (CMD) 390 N. |
ShearStrength | To BS EN 1052-4, pre-compression 0.2 N/mm²: 0.33 N/mm². |
Flexural strength | To DD 86-1 (mean value), 0.18 N/mm². |
Radon permeability | To SP method 3873, <4.8E-12 m²/s. |
Accessories | None. Pre-formed corner units. Guidance for specification option: For use to return corners for full perimeter cavity tray. Pre-formed change in level and stepped units. Guidance for specification option: For use where a cavity tray must step up or down to follow ground level. Pre-formed telescopic underfloor vent collars. Guidance for specification option: To allow for sealing around ventilation ducts. Pre-formed stop end units. Guidance for specification option: For capping off the ends of a cavity tray run and at column projections. Manufacturer guidanceConsult manufacturer's literature for options and insert details as required. |
Material | Polymer |