Tested in accordance with EN 16361/ EN 14351-1 the PST automatic door system consists of thermally insulated Gilgen PST door profiles matched with Gilgen’s SLX-M operator. This combination delivers both an energy efficient and visually appealing solution with low U-values (1.1–1.8 W/m²k), low air permeability, high wind load capacity and high resistance to driving rain.

The slimline PST door profile delivers a robust thermal barrier combined with a low visible profile suitable for high volume, heavy duty, retail trade, hotels, offices, transport terminals, hospitals, schools, colleges, garden centres and leisure. All equipment is designed to meet the rigorous safety requirements of BS EN 16005, Building Regulations (E & W) Part M and The Equality Act 2010, BS 8300. Furthermore, equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.

General information

Finish

Polyester powder coated, RAL

Insert colour requirements.

Uniclass 2015

Pr_30_59_24_80 Sliding door and partition setsPrimary

CAWS

L20/490 Automatic doors

L20/55 Doorsets

L20/60 Doors

Specification data - Sliding door and partition sets

Product Reference

PST Insulated Automatic Sliding Door System

Door

-

Door configuration

Bi parting no fixed side panels

Bi parting two fixed side panels

Bi-parting, two fixed panels and fan light

Single sliding, no fixed panel

Single sliding, one fixed panel

Clearance width

700–1500 mm (single sliding); 800–3000 mm (bi-parting).

Height

2100–3000 mm; insert requirements.

Finish

Polyester powder coated, RAL

Insert colour requirements.

Glazing

Insulating glass, double glazing 24–28 mm thickness. Triple glazing 31–38 mm. Installation specific; please consult manufacturer and insert requirements.

Control

D Bedix hard wired control unit

F Key

Kombi D Bedix

Six position key switch

Activation

Integration with access control systems

Manual push pad

Motion sensors

Touch-less push pad

Locking and security

Multipoint

Standard locking built into drive mechanism

Door movement guide

Recessed floor track

Surface mounted fixed point guide

Rear door safety

Installation specific please consult manufacturer.

Standard product features

Drive system:

SLX-M sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a very slender in profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.

Safety:

  • Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimizing pedestrian safety.
  • Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.
  • Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.
  • Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within three seconds after activation by the activators in the escape direction (or within five seconds in the event of the loss of power).

Operation:

24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open.

Door weight:

  • Single sliding doors: 1 x 150 kg.
  • Bi-parting doors: 2 x 250 kg.

Power requirements:

230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

Product Options

Rear door safety:

Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are:

  • 900 mm high, firmly secured, solid glazed barrier, in accordance with BSEN 16005.
  • 2.5 m high, fully glazed pocket screen complying with BS EN 16005.

Control:

  • D Bedix hard wired programming key pad (incorporating digital display screen) designed for installation in a central control panel. Configured for automatic/ manual/ night/ exit/ open door operating modes.
  • Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.
  • Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.
  • F Key: Multi user, compact programmable portable unit enabling restricted personnel access.
  • Six position key switch. Single point door control but with NO fault identification.

Operation:

Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals, voice message systems to assist partially sighted people and integrates with access control systems.

Door movement guide:

Surface mounted fixed point guide enhances efficiency of door movement.

Recessed floor track:

Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain.

Third party certifications
  • Air permeability Class 2 (PPD2) in accordance with EN 12207
  • CE: Approved
  • TUV: Approved
  • Class 5A water tightness in accordance with EN 12208
  • Wind Load Capacity PPD 800A, PPD 800B, PPD 700C