Verified by manufacturer 4 months ago
A non-combustible class A1 inverted roof insulation.
FOAMGLAS® INVATHERMᵀᴹ has been engineered to meet the demand for a class A1 inverted roof insulation board for use on roofs, roof terraces and balconies. Suitable for use with any inverted roof waterproofing membrane including hot melt, liquid applied, reinforced bitumen membrane or single ply membrane.
Consisting of cellular glass with a pre-applied inorganic coating on the topside both the core material Foamglas® InvaThermᵀᴹ is manufactured from specially graded recycled glass (≥60%) and natural raw materials which are available in abundant supply (sand, dolomite, lime). Totally inorganic Foamglas® InvaThermᵀᴹ contains no ozone depleting propellants, flame resistant additives or binders, VOC or other volatile substances.
Features and benefits:
Color | Grey |
Finish | Coated |
Material | Sand Glass Limestone |
Length | 600 mm |
Width | 450 mm |
Height | 100 mm 120 mm 140 mm 160 mm 200 mm |
Uniclass | |
CAWS | Q37/310 Inverted roof insulation J31/337 Cellular glass insulation J42/440 Inverted roof insulation J31/340 Inverted roof insulation J41/440 Inverted roof insulation |
Standard | Class A1 to BS EN 13501-1. |
Reaction to fire | Euroclass A1. |
Thermal conductivity (maximum) | ≤0.043 W/m·K.Manufacturer guidanceTo EN ISO 10456. |
Thickness | 100 mm.120 mm.140 mm.160 mm.200 mm.Manufacturer guidance±2 mm, to EN 823. See also Base layer thickness below. |
Compressive strength (minimum) | ≤400 kPa.Manufacturer guidanceTo EN 826 annexe A. |
Density | 100 kg/m³.Manufacturer guidance±15% to EN 1602. |
Recycled content | Specially graded recycled glass (≥60%). |
ColorAppearance | Grey. Guidance for specification option: As product is made from natural materials the colour cannot be guaranteed and can vary in batches. |
Core | Specially graded recycled glass and natural raw materials. Guidance for specification option: ≥60% recycled glass consists of highly selected postconsumer glass and highly selected production scrap/co-products. |
Base layer thickness | 50 mm. 60 mm. 70 mm. 80 mm. 90 mm. Manufacturer guidanceT3+ base layer. |
Length | 600 mm. Manufacturer guidance± 2 mm, to EN 822 |
Width | 450 mm. Manufacturer guidance± 2 mm, to EN 822 |
Load | ≤1.5 kPa. Manufacturer guidancePoint load/ Point load top, EN 12430/ EN 826 annexe A |
BendingStrength | ≤400 kPa. Manufacturer guidanceEN 12089 |
TensileStrength | ≤100 kPa. Manufacturer guidanceEN 1607 |
Dimensional stability | 70.90, ∆εl,b ≤0.5%, ∆εd ≤1%. Manufacturer guidance(after 48 h @ 70ºC & 90% RH) to EN 1604 |
Water absorption | ≤0.5 kg/m². Manufacturer guidanceon short term |
Water vapour transmission | ∞. |
Freeze/ Thaw Resistance | Resistant. |
Service temperature | -265°C to +430°C. Manufacturer guidanceLimits to ISO 14025 and EN 15804 |
Water vapour resistance | ∞μ. Manufacturer guidanceEN ISO 10456 |
Melting point | >1000°C. Manufacturer guidancecf DIN 4102-17 |
Coefficient of thermal expansion | 9 x 10⁶K¹. Manufacturer guidanceEN 13471 |
Specific heat | 1000 J/(kg·K). Manufacturer guidanceEN ISO 10456 |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 60 % |